Page 2 - Feature
NI USB-6008/6009 User Guide and Specifications 2 ni.com Figure 1. NI USB-6008/6009 Top View Figure 2. NI USB-6008/6009 Back View Table 2. Differences Between the NI USB-6008 and NI USB-6009 Feature NI USB-6008 NI USB-6009 AI Resolution 12 bits differential, 11 bits single-ended 14 bits differential,...
Page 3 - Dimensions; Figure 3 illustrates the dimensions of the NI USB-6008/6009 device.; Safety Guidelines; Caution
© National Instruments Corporation 3 NI USB-6008/6009 User Guide and Specifications Dimensions Figure 3 illustrates the dimensions of the NI USB-6008/6009 device. Figure 3. NI USB-6008/6009 in Millimeters (Inches) Safety Guidelines Caution Operate the NI USB-6008/6009 only as described in these oper...
Page 5 - Related Documentation; DAQ Getting Started Guide; Start»All Programs»National Instruments»NI-DAQ»; Note
© National Instruments Corporation 5 NI USB-6008/6009 User Guide and Specifications • Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a st...
Page 7 - NI Measurement Studio Help; ANSI C without NI Application Software; NI-DAQmx C Reference Help; .NET Languages without NI Application Software
© National Instruments Corporation 7 NI USB-6008/6009 User Guide and Specifications can create channels and tasks, and write your own applications in your ADE using the NI-DAQmx API. For help with NI-DAQmx methods and properties, refer to the NI-DAQmx .NET Class Library or the NI-DAQmx Visual C++ Cl...
Page 8 - Device Documentation and Specifications
NI USB-6008/6009 User Guide and Specifications 8 ni.com Library»Using the Measurement Studio .NET Class Libraries to view conceptual topics for using NI-DAQmx with Visual C# and Visual Basic .NET. To get to the same help topics from within Visual Studio, go to Help»Contents . Select Measurement Stud...
Page 9 - Training Courses; Installing the Software; Installing Other Software; for USB Devices Getting Started Guide; NI-DAQmx Base Getting Started Guide; Start»All Programs»National Instruments»
© National Instruments Corporation 9 NI USB-6008/6009 User Guide and Specifications Note All NI-DAQmx Base documentation for Mac OS X is installed at /Application s /National In s trument s /NI-DAQmx Ba s e/documentation . Training Courses If you need more help getting started developing an applicat...
Page 12 - LED Indicator; LED State; Not lit
NI USB-6008/6009 User Guide and Specifications 12 ni.com Note Once you label the screw terminal blocks, you must only insert them into the matching combicon jack, as indicated by the overlay label on the NI USB-6008/6009 device. 4. Connect the wiring to the appropriate screw terminals. Connecting th...
Page 13 - Module
© National Instruments Corporation 13 NI USB-6008/6009 User Guide and Specifications Table 4 lists the analog terminal assignments, and Table 5 lists the digital terminal assignments. Table 4. Analog Terminal Assignments Module Terminal Signal, Single - Ended Mode Signal, Differential Mode 1 GND GND...
Page 14 - GND
NI USB-6008/6009 User Guide and Specifications 14 ni.com Table 5. Digital Terminal Assignments Module Terminal Signal 17 P0.0 18 P0.1 19 P0.2 20 P0.3 21 P0.4 22 P0.5 23 P0 6 24 P0.7 25 P1.0 26 P1.1 27 P1.2 28 P1.3 29 PFI 0 30 +2.5 V 31 +5 V 32 GND 32 31 30 29 2 8 27 26 25 24 23 22 21 20 19 1 8 17
Page 16 - Analog Input; MUX
NI USB-6008/6009 User Guide and Specifications 16 ni.com Analog Input You can connect analog input signals to the NI USB-6008/6009 through the I/O connector. Refer to Table 6 for more information about connecting analog input signals. Analog Input Circuitry Figure 7 illustrates the analog input circ...
Page 17 - AI FIFO
© National Instruments Corporation 17 NI USB-6008/6009 User Guide and Specifications AI FIFO The NI USB-6008/6009 can perform both single and multiple A/D conversions of a fixed or infinite number of samples. A first-in-first-out (FIFO) buffer holds data during AI acquisitions to ensure that no data...
Page 19 - Digital Trigger; Analog Output
© National Instruments Corporation 19 NI USB-6008/6009 User Guide and Specifications Figure 11. Connecting a Referenced Single-Ended Voltage Signal Digital Trigger When an AI task is defined, you can configure PFI 0 as a digital trigger input. When the digital trigger is enabled, the AI task waits f...
Page 20 - Minimizing Glitches on the Output Signal; for more information about minimizing
NI USB-6008/6009 User Guide and Specifications 20 ni.com DACs Digital-to-analog converts (DACs) convert digital codes to analog voltages. Connecting Analog Output Loads To connect loads to the NI USB-6008/6009, connect the positive lead of the load to the AO terminal, and connect the ground of the l...
Page 21 - Digital I/O Circuitry; Source/Sink Information; for more information about how
© National Instruments Corporation 21 NI USB-6008/6009 User Guide and Specifications Digital I/O Circuitry Figure 14 shows P0.<0..7> connected to example signals configured as digital inputs and digital outputs. You can configure P1.<0..3> similarly. Figure 14. Example of Connecting a Lo...
Page 22 - Place an ammeter in series with the load.
NI USB-6008/6009 User Guide and Specifications 22 ni.com Figure 15. Example of Connecting an External User-Provided Resistor Complete the following steps to determine the value of the user-provided pull-up resistor: 1. Place an ammeter in series with the load. 2. Place a variable resistor between th...
Page 23 - Static DIO; Event Counter; Specifications
© National Instruments Corporation 23 NI USB-6008/6009 User Guide and Specifications I/O Protection To protect the NI USB-6008/6009 against overvoltage, undervoltage, and overcurrent conditions, as well as ESD events, you should avoid these fault conditions by using the following guidelines: • If yo...
Page 24 - Reference and Power Sources; software selectable
NI USB-6008/6009 User Guide and Specifications 24 ni.com Reference and Power Sources The NI USB-6008/6009 creates an external reference and supplies a power source. All voltages are relative to COM unless otherwise noted. +2.5 External References The NI USB-6008/6009 creates a high-purity reference ...
Page 25 - Range
© National Instruments Corporation 25 NI USB-6008/6009 User Guide and Specifications Timing accuracy..................................... 100 ppm of actual sample rate Input range Single-ended ................................... ±10 V Differential ...................................... ±20 V 1 , ±10...
Page 26 - mV maximum at full scale
NI USB-6008/6009 User Guide and Specifications 26 ni.com Analog Output Analog outputs ........................................2 Output resolution ....................................12 bits Maximum update rate .............................150 Hz, software-timed Output range ............................
Page 27 - External Voltage; to 5 V; Level
© National Instruments Corporation 27 NI USB-6008/6009 User Guide and Specifications Compatibility ......................................... TTL, LVTTL, CMOS Absolute maximum voltage range ......... – 0.5 to 5.8 V with respect to GND Pull-up resistor ....................................... 4.7 k Ω t...
Page 28 - USB; Physical Characteristics
NI USB-6008/6009 User Guide and Specifications 28 ni.com Minimum low pulse width ......................100 ns Input high voltage ...................................2.0 V Input low voltage ....................................0.8 V Bus Interface USB specification ...................................USB...
Page 29 - Safety; MAINS; Safety Standards; Hazardous Locations
© National Instruments Corporation 29 NI USB-6008/6009 User Guide and Specifications Safety If you need to clean the module, wipe it with a dry towel. Safety Voltages Connect only voltages that are within these limits. Channel-to-GND .................................... ±30 V max, Measurement Catego...
Page 30 - EN 61326 EMC requirements Minimum Immunity; CE Compliance
NI USB-6008/6009 User Guide and Specifications 30 ni.com Environmental The NI USB-6008/6009 device is intended for indoor use only. Operating temperature (IEC 60068-2-1 and IEC 60068-2-2)......0 to 55 °C Operating humidity (IEC 60068-2-56) ...................................5 to 95% RH, noncondensin...
Page 31 - Environmental Management; NI and the; Waste Electrical and Electronic Equipment (WEEE); EU Customers; Where to Go for Support; ⬉ᄤֵᙃѻક∵ᵻࠊᄣ⧚ࡲ⊩ ˄Ё; RoHS
© National Instruments Corporation 31 NI USB-6008/6009 User Guide and Specifications Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our produ...