Page 3 - Important Information
Important Information Warranty The NI PXIe-1065 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defec...
Page 4 - Contents; About This Manual
© National Instruments Corporation v NI PXIe-1065 User Manual Contents About This Manual Conventions ................................................................................................................... viiRelated Documentation..............................................................
Page 5 - Glossary
Contents NI PXIe-1065 User Manual vi ni.com Installing a PXI Express System Controller .................................................................. 2-6Installing Peripheral Modules........................................................................................ 2-8Power Inhibit Switch L...
Page 6 - Conventions
© National Instruments Corporation vii NI PXIe-1065 User Manual About This Manual The NI PXIe-1065 User Manual describes the features of the NI PXIe-1065 chassis and contains information about configuring the chassis, installing the modules, and operating the chassis. Conventions The following conve...
Page 7 - Related Documentation
About This Manual NI PXIe-1065 User Manual viii ni.com Related Documentation The following documents contain information that you might find helpful as you read this manual: • IEEE 1101.1-1991, IEEE Standard for Mechanical Core Specifications for Microcomputers Using IEC 603-2 Connectors • IEEE 1101...
Page 8 - Getting Started; Unpacking
© National Instruments Corporation 1-1 NI PXIe-1065 User Manual 1 Getting Started This chapter describes the key features of the NI PXIe-1065 chassis and lists the kit contents and optional equipment you can order from National Instruments. Unpacking Carefully inspect the shipping container and the ...
Page 9 - Key Features
Chapter 1 Getting Started NI PXIe-1065 User Manual 1-2 ni.com If you are missing any of the items listed in Table 1-1, or if you have the incorrect AC power cable, contact National Instruments. Key Features The NI PXIe-1065 chassis combines a high-performance 18-slot PXI Express backplane with a hig...
Page 11 - Chassis Description
Chapter 1 Getting Started NI PXIe-1065 User Manual 1-4 ni.com Chassis Description Figures 1-1 and 1-2 show the key features of the NI PXIe-1065 chassis front and back panels. Figure 1-1 shows the front view of the NI PXIe-1065. Figure 1-2 shows the rear view of the NI PXIe-1065. Figure 1-1. Front Vi...
Page 12 - Optional Equipment; EMC Filler Panels
Chapter 1 Getting Started © National Instruments Corporation 1-5 NI PXIe-1065 User Manual Figure 1-2. Rear View of the NI PXIe-1065 Chassis Optional Equipment Contact National Instruments to order the following options for the NI PXIe-1065 chassis. EMC Filler Panels Optional EMC filler panel kits ar...
Page 13 - Slot Blockers; NI PXIe-1065 Chassis Backplane Overview; Interoperability with CompactPCI; System Controller Slot
Chapter 1 Getting Started NI PXIe-1065 User Manual 1-6 ni.com Slot Blockers Optional slot blocker kits are available from National Instruments for improved thermal performance when all slots are not used. NI PXIe-1065 Chassis Backplane Overview This section provides an overview of the backplane feat...
Page 14 - Hybrid Peripheral Slots; PXI Peripheral Slots
Chapter 1 Getting Started © National Instruments Corporation 1-7 NI PXIe-1065 User Manual By default, the system controller will control the power supply with the PS_ON# signals. A logic low on this line will turn the power supply on. Note The Inhibit Mode switch on the rear of the chassis must be i...
Page 15 - PXI Express Peripheral Slots
Chapter 1 Getting Started NI PXIe-1065 User Manual 1-8 ni.com PXI Express Peripheral Slots There are three PXI Express peripheral slots: slots 8 –10. Slot 8 is directly connected to the system slot with a x4 PCI Express link. Slots 9 and 10 are connected to the system slot through a PCI Express swit...
Page 16 - PXI Local Bus
Chapter 1 Getting Started © National Instruments Corporation 1-9 NI PXIe-1065 User Manual Figure 1-3. PXIe_DSTAR and PXI Star Connectivity Diagram PXI Local Bus The PXI backplane local bus is a daisy-chained bus that connects each peripheral slot with adjacent peripheral slots to the left and right,...
Page 17 - PXI Trigger Bus
Chapter 1 Getting Started NI PXIe-1065 User Manual 1-10 ni.com Local bus signals may range from high-speed TTL signals to analog signals as high as 42 V. Initialization software uses the configuration information specific to each adjacent peripheral module to evaluate local bus compatibility. Figure...
Page 18 - System Reference Clock
Chapter 1 Getting Started © National Instruments Corporation 1-11 NI PXIe-1065 User Manual assignments) can be configured through Measurement & Automation Explorer (MAX). Dynamic routing of triggers (automatic line assignments) is supported through certain National Instruments drivers like NI-DA...
Page 22 - Installation and Configuration; Safety Information
© National Instruments Corporation 2-1 NI PXIe-1065 User Manual 2 Installation and Configuration This chapter describes how to prepare and operate the NI PXIe-1065 chassis. Before connecting the chassis to a power source, read this chapter and the Read Me First: Safety and Radio-Frequency Interferen...
Page 23 - Chassis Cooling Considerations; Providing Adequate Clearance
Chapter 2 Installation and Configuration NI PXIe-1065 User Manual 2-2 ni.com • Part Replacement —Only service this equipment with parts that are exact replacements, both electrically and mechanically. Contact National Instruments for replacement part information. Installation of parts with those tha...
Page 25 - Chassis Ambient Temperature Definition
Chapter 2 Installation and Configuration NI PXIe-1065 User Manual 2-4 ni.com Figure 2-2. NI PXIe-1065 Vents Chassis Ambient Temperature Definition The chassis fan control system uses intake air temperature as the input for controlling fan speeds when in Auto Fan Speed mode. Because of this, the chas...
Page 26 - Setting Fan Speed; Installing Filler Panels; Rack Mounting
Chapter 2 Installation and Configuration © National Instruments Corporation 2-5 NI PXIe-1065 User Manual rated ambient temperature as stated in Appendix A, Specifications . If the temperature exceeds the stated spec the power switch LED will blink green, as discussed in the Power Inhibit Switch LED ...
Page 27 - Connecting to Power Source; Installing a PXI Express System Controller
Chapter 2 Installation and Configuration NI PXIe-1065 User Manual 2-6 ni.com If your power outlet does not have an appropriate ground connection, you must connect the premise safety ground to the chassis grounding screw located on the rear panel. Refer to Figure 1-2, Rear View of the NI PXIe-1065 Ch...
Page 29 - Installing Peripheral Modules
Chapter 2 Installation and Configuration NI PXIe-1065 User Manual 2-8 ni.com Figure 2-4 shows a PXI Express system controller installed in the system controller slot of a NI PXIe-1065 chassis. You can place CompactPCI, CompactPCI Express, PXI, or PXI Express modules in other slots depending on the s...
Page 31 - Power Inhibit Switch LED Indicator; Remote Voltage Monitoring and Control
Chapter 2 Installation and Configuration NI PXIe-1065 User Manual 2-10 ni.com Power Inhibit Switch LED Indicator The chassis power inhibit switch has an integrated LED. This LED indicates one of four different conditions: • If the inhibit switch LED is steady green (not flashing), the chassis is pow...
Page 33 - Inhibit Mode Switch; PXI_CLK10 Rear Connectors; PXI Express System Configuration with MAX
Chapter 2 Installation and Configuration NI PXIe-1065 User Manual 2-12 ni.com Inhibit Mode Switch On the rear panel of the chassis there is an Inhibit Mode switch. Refer to Figure 1-2, Rear View of the NI PXIe-1065 Chassis , for the location. The Inhibit Mode switch is recessed to prevent it from ac...
Page 34 - PXI-1 System Configuration
Chapter 2 Installation and Configuration © National Instruments Corporation 2-13 NI PXIe-1065 User Manual double-driving and potentially damaging trigger lines. For more information about routing and reserving PXI triggers, refer to KnowledgeBase 3TJDOND8 at ni.com/support . The configuration steps ...
Page 35 - Trigger Configuration in MAX
Chapter 2 Installation and Configuration NI PXIe-1065 User Manual 2-14 ni.com 4. Click the PXI system controller. The chassis (or multiple chassis, in a multichassis configuration) is listed below it. Identify each chassis by right-clicking its entry, then selecting the appropriate chassis model thr...
Page 36 - PXI Trigger Bus Routing
Chapter 2 Installation and Configuration © National Instruments Corporation 2-15 NI PXIe-1065 User Manual Complete the following steps to reserve these trigger lines in MAX. 1. In the Configuration tree, click on the PXI chassis branch you want to configure. 2. Then, in the right-hand pane, toward t...
Page 37 - Using System Configuration and Initialization Files
Chapter 2 Installation and Configuration NI PXIe-1065 User Manual 2-16 ni.com Using System Configuration and Initialization Files The PXI Express specification allows many combinations of PXI Express chassis and system modules. To assist system integrators, the manufacturers of PXI Express chassis a...
Page 38 - Maintenance; Service Interval; Cleaning; Interior Cleaning
© National Instruments Corporation 3-1 NI PXIe-1065 User Manual 3 Maintenance This chapter describes basic maintenance procedures you can perform on the NI PXIe-1065 chassis. Caution Disconnect the power cable prior to servicing a NI PXIe-1065 chassis. Service Interval Clean dust from the chassis ex...
Page 39 - Exterior Cleaning; Resetting the AC Mains Circuit Breaker
Chapter 3 Maintenance NI PXIe-1065 User Manual 3-2 ni.com Exterior Cleaning Clean the exterior surfaces of the chassis with a dry lint-free cloth or a soft-bristle brush. If any dirt remains, wipe with a cloth moistened in a mild soap solution. Remove any soap residue by wiping with a cloth moistene...
Page 40 - Replacing the Modular Power Supply; Removal; Installation
Chapter 3 Maintenance © National Instruments Corporation 3-3 NI PXIe-1065 User Manual 6. The over-current condition that caused the circuit breaker to trip may be due to a faulty CompactPCI or PXI Express module. Refer to the documentation supplied with the modules for troubleshooting information. R...
Page 42 - Electrical
© National Instruments Corporation A-1 NI PXIe-1065 User Manual A Specifications This appendix contains specifications for the NI PXIe-1065 chassis. Caution Specifications are subject to change without notice. Electrical AC Input Input voltage range................................. 100 to 240 VAC Op...
Page 43 - DC Output
Appendix A Specifications NI PXIe-1065 User Manual A-2 ni.com DC Output DC current capacity (I MP ) Note Maximum combined +3.3 V, +5 V, and +12 V power is 699 W. Maximum total power is 701.5 W. The maximum power dissipated in the system slot should not exceed 140 W. Backplane pin current capacity Lo...
Page 44 - Chassis Cooling
Appendix A Specifications © National Instruments Corporation A-3 NI PXIe-1065 User Manual Maximum ripple and noise (20 MHz bandwidth) Over-current protection .......................... All outputs protected from short circuit and overload with automatic recovery Over-voltage protection 3.3 V and 5 V...
Page 45 - Environmental
Appendix A Specifications NI PXIe-1065 User Manual A-4 ni.com Environmental Maximum altitude...................................2,000 m (800 mbar) (at 25 °C ambient) Pollution Degree .....................................2 For indoor use only. Operating Environment Ambient temperature range .............
Page 46 - Acoustic Emissions; Safety; Electromagnetic Compatibility
Appendix A Specifications © National Instruments Corporation A-5 NI PXIe-1065 User Manual Acoustic Emissions Sound Pressure Level (at Operator Position) (Tested in accordance with ISO 7779. Meets MIL-PRF-28800F requirements.) Auto fan (up to ~30 °C ambient) ........... 45.0 dBA High fan................
Page 47 - CE Compliance; Waste Electrical and Electronic Equipment (WEEE); ⬉ᄤֵᙃѻક∵ᵻࠊᄣ⧚ࡲ⊩ ˄Ё; RoHS
Appendix A Specifications NI PXIe-1065 User Manual A-6 ni.com Note For EMC compliance, operate this device with shielded cabling. CE Compliance This product meets the essential requirements of applicable European Directives as follows: • 2006/95/EC; Low-Voltage Directive (safety) • 2004/108/EC; Elec...
Page 48 - Backplane
Appendix A Specifications © National Instruments Corporation A-7 NI PXIe-1065 User Manual Backplane Size ......................................................... 3U-sized; one system slot (with three system expansion slots) and 17 peripheral slots.Compliant with IEEE 1101.10 mechanical packaging.PX...
Page 49 - External Clock Source
Appendix A Specifications NI PXIe-1065 User Manual A-8 ni.com Maximum jitter .......................................3 ps RMS phase-jitter (10 Hz–12 kHz range) 2 ps RMS phase-jitter (12 kHz–20 MHz range) Duty-factor for PXIe_CLK100 ...............45%–55% Absolute single-ended voltage swing(When each ...
Page 50 - PXI Star Trigger; Mechanical
Appendix A Specifications © National Instruments Corporation A-9 NI PXIe-1065 User Manual PXIe_SYNC_CTRL V IH .......................................................... 2.0 –5.5 V V IL .......................................................... 0– 0.8 V PXI Star Trigger Maximum slot-to-slot skew .......
Page 55 - Pinouts
© National Instruments Corporation B-1 NI PXIe-1065 User Manual B Pinouts This appendix describes the connector pinouts for the NI PXIe-1065 chassis backplane. Table B-1 shows the XP1 connector pinout for the System Controller slot. Table B-2 shows the XP2 Connector Pinout for the System Controller ...
Page 56 - System Controller Slot Pinouts
Appendix B Pinouts NI PXIe-1065 User Manual B-2 ni.com System Controller Slot Pinouts Table B-1. XP1 Connector Pinout for the System Controller Slot Pins Signals A GND B 12V C 12V D GND E 5V F 3.3V G GND Table B-2. XP2 Connector Pinout for the System Controller Slot Pin A B ab C D cd E F ef 1 3PETp1...
Page 57 - System Timing Slot Pinouts
Appendix B Pinouts © National Instruments Corporation B-3 NI PXIe-1065 User Manual System Timing Slot Pinouts 7 1PETp3 1PETn3 GND 1PERp3 1PERn3 GND 2PETp0 2PETn0 GND 8 2PETp1 2PETn1 GND 2PERp1 2PERn1 GND 2PERp0 2PERn0 GND 9 2PETp2 2PETn2 GND 2PERp2 2PERn2 GND 2PETp3 2PETn3 GND 10 3PETp0 3PETn0 GND 3...
Page 59 - Peripheral Slot Pinouts
Appendix B Pinouts © National Instruments Corporation B-5 NI PXIe-1065 User Manual Peripheral Slot Pinouts Table B-9. P1 Connector Pinout for the Peripheral Slot Pin Z A B C D E F 25 GND 5V REQ64# ENUM# 3.3V 5V GND 24 GND AD[1] 5V V(I/O) AD[0] ACK64# GND 23 GND 3.3V AD[4] AD[3] 5V AD[2] GND 22 GND A...
Page 61 - Hybrid Slot Pinouts
Appendix B Pinouts © National Instruments Corporation B-7 NI PXIe-1065 User Manual Hybrid Slot Pinouts Table B-11. P1 Connector Pinout for the Hybrid Slot Pin Z A B C D E F 25 GND 5V REQ64# ENUM# 3.3V 5V GND 24 GND AD[1] 5V V(I/O) AD[0] ACK64# GND 23 GND 3.3V AD[4] AD[3] 5V AD[2] GND 22 GND AD[7] GN...
Page 65 - Symbols
© National Instruments Corporation G-1 NI PXIe-1065 User Manual Glossary Symbol Prefix Value p pico 10 – 12 n nano 10 – 9 μ micro 10 – 6 m milli 10 – 3 k kilo 10 3 M mega 10 6 G giga 10 9 T tera 10 12 Symbols ° Degrees. ≥ Equal or greater than. ≤ Equal or less than. % Percent. A A Amperes. AC Altern...
Page 71 - Index
© National Instruments Corporation I-1 NI PXIe-1065 User Manual Index A AC power cables (table), 1-2 B backplane hybrid peripheral slots, 1-7interoperability with CompactPCI, 1-6overview, 1-6PXI Express peripheral slots, 1-8PXI local bus, routing, 1-9PXI peripheral slots, 1-7PXIe_SYNC_CTRL, 1-14spec...