Page 2 - Conventions; File»Page Setup»Options; Read Me First: Safety and; bold
NI Digital Waveform Generator/Analyzer Guide 2 ni.com 5. Installing the Hardware ..........................................................................8 Installing a PXI Module .....................................................................8Installing a PCI Device ............................
Page 3 - CompactPCI; monospace bold; PCI; Verifying the System Components; Minimum System Requirements; Pentium 200 MHz or equivalent processor
© National Instruments Corporation 3 NI Digital Waveform Generator/Analyzer Guide CompactPCI CompactPCI refers to the core specification defined by the PCI Industrial Computer Manufacturers Group (PICMG). italic Italic text denotes variables, emphasis, or a cross reference. This font also denotes te...
Page 4 - Recommended System; Device; Accessory
NI Digital Waveform Generator/Analyzer Guide 4 ni.com • 1/8 in. flathead screwdriver • Number 1 Phillips screwdriver • Microsoft Internet Explorer 5.5 or later • Measurement & Automation Explorer (MAX) 3.1 or later • A screen resolution of 800 × 600 with 256 colors (required for the NI Script Ed...
Page 5 - Caution; Never; Verifying the Kit Contents; NI Digital Waveform Generator/Analyzer
© National Instruments Corporation 5 NI Digital Waveform Generator/Analyzer Guide • Windows 2000/NT/XP, with all available critical updates and service packs • One of the following application development environments (ADEs): – LabVIEW 7.0 or later (LabVIEW 7.1 or later is required to use the NI-HSD...
Page 6 - Documentation; Read Me First: Safety and Radio-Frequency Interference; Installing the Software; Choose and Install Your ADE
NI Digital Waveform Generator/Analyzer Guide 6 ni.com ❑ Other documentation included with the digital waveform generator/analyzer and driver software. Refer to the Documentation section for a list of the documentation you may have. Documentation The NI digital waveform generator/analyzer kit may als...
Page 7 - Start»Run; Measurement & Automation Explorer Remote Systems Help; Help»Help Topics»Remote Systems; NI Script Editor; NI Script Editor Help; Help»NI Script Editor Help; (Optional) Install the NI Digital Waveform Editor; Installing the Hardware
© National Instruments Corporation 7 NI Digital Waveform Generator/Analyzer Guide Install NI-HSDIO NI-HSDIO features a set of operations and attributes that allow you to programmatically configure and control the digital waveform generator/analyzer. To install NI-HSDIO, complete the following steps:...
Page 8 - I Received a Thermal; Installing a PXI Module; Retrofitting Your PXI Module Note to Users
NI Digital Waveform Generator/Analyzer Guide 8 ni.com information on re-enabling your device, refer to the I Received a Thermal Shutdown Error section in Appendix B: Troubleshooting . Installing a PXI Module To install the module, refer to Figure 1 and complete the following steps: Figure 1. PXI Ins...
Page 9 - Note; NI recommends that you install slot blockers between; Maintaining PXI Systems; During operation the metal surfaces of PXI modules may
© National Instruments Corporation 9 NI Digital Waveform Generator/Analyzer Guide 7. Holding the module by the ejector handle, slide it into an empty slot, ensuring that the base card (on the left when looking at the front of the module) engages with the card guides in the chassis. 8. Slide the modu...
Page 10 - Installing a PCI Device; To install your PCI device, complete the following steps:; Secure the device with the screw provided in the kit.; It is important to completely screw the device into the PCI
NI Digital Waveform Generator/Analyzer Guide 10 ni.com Installing a PCI Device To install your PCI device, complete the following steps: 1. Power off and unplug the PC. 2. If the PC has multiple fan speed settings, ensure that the fans are set to the highest setting. 3. Remove the PC cover. 4. Inser...
Page 11 - disrupt the necessary air circulation in the PC.; Maintaining PCI Systems; Configuring and Testing in MAX; Launch MAX to configure and test the digital waveform; Devices and Interfaces; target IP address or name, expand it, and then expand; Devices and; If your device does not appear under NI-DAQmx Devices,; File»Refresh; a. Right-click the device you want to test and select
© National Instruments Corporation 11 NI Digital Waveform Generator/Analyzer Guide a different chassis. Improperly secured devices may affect the accuracy of device specifications. 6. Before operating the device, install all filler panels. Missing filler panels disrupt the necessary air circulation ...
Page 12 - Tip; Using the Test Panel to Generate and Acquire Data
NI Digital Waveform Generator/Analyzer Guide 12 ni.com Figure 3. Configuration Tree Shortcut Menu b. When the self-test finishes, a message window appears to indicate if an error occurred. If an error occurred, refer to ni.com/support for troubleshooting information. Tip If you need to reset the dev...
Page 13 - Play; NI Digital Waveform Generator/Analyzer Help; Acquisition
© National Instruments Corporation 13 NI Digital Waveform Generator/Analyzer Guide 6. Enter values for the generation and acquisition voltages in the controls below the Clock Frequency control. You can choose from standard logic families (NI 654 X /655 X ) or enter High and Low values to create your...
Page 14 - Connecting Signals; Appendix A: Device Front Panels; Connecting Cables and Accessories; Using Accessories (NI 654; Guide
NI Digital Waveform Generator/Analyzer Guide 14 ni.com 7. Connecting Signals This section discusses what connections you can make to the device, and how to connect signals to the device for performing dynamic acquisition and dynamic generation. For device front panel diagrams and connector descripti...
Page 16 - NI Digital Waveform; Wiring for Common Measurements; Dynamic Generation
NI Digital Waveform Generator/Analyzer Guide 16 ni.com Note If you are creating your own accessory to use with your device, you can purchase the mating connector for the VHDCI cable from NI (part number 778914-01). Whether you use NI cables and accessories or design your own, you should properly ter...
Page 17 - Dynamic Acquisition
© National Instruments Corporation 17 NI Digital Waveform Generator/Analyzer Guide Dynamic Acquisition When performing dynamic acquisition with the NI 654 X /655 X , the source generating the signals needs a matched source impedance as close to 50 Ω as possible to minimize signal reflections and mai...
Page 18 - NI-HSDIO Instrument Driver; Information about programming with NI-HSDIO is available in the; Programming»Getting Started with; in the; Front Panels and Connectors; front panels contain four connectors—three SMB jacks
NI Digital Waveform Generator/Analyzer Guide 18 ni.com 8. Programming the Digital Waveform Generator/Analyzer You can generate or acquire digital data with the NI digital waveform generator/analyzer using NI-HSDIO. You also can run the NI-HSDIO examples to demonstrate the functionality of your devic...
Page 21 - front panels and pinout, which are identical to
© National Instruments Corporation 21 NI Digital Waveform Generator/Analyzer Guide Figure 9 shows the NI 6551 front panels and pinout, which are identical to those of the NI 6552. The DDC signals are described in Table 5. The SMB connectors are described in Table 7. The LEDs are described in Tables ...
Page 22 - If you are designing a custom cabling solution with connector
NI Digital Waveform Generator/Analyzer Guide 22 ni.com NI 656 X Front Panels and Connectors The NI 656 X front panels contain four connectors—three SMB jacks (CLK IN, PFI 0, and CLK OUT) and one 73-pin 12x Infiniband connector (DIGITAL DATA & CONTROL, or DDC). Figure 10 shows the NI 6561 front p...
Page 24 - If you are designing a custom cabling solution with; Pins
NI Digital Waveform Generator/Analyzer Guide 24 ni.com Note If you are designing a custom cabling solution with connector (779157-01) and cable (192744-01), the NI665 X pinout is reversed at the end connector. For example, the signal shown on pin 1 shown in the previous figure would map to pin 73 at...
Page 26 - Appendix B: Troubleshooting; not; Color
NI Digital Waveform Generator/Analyzer Guide 26 ni.com Appendix B: Troubleshooting Device Front Panel ACCESS LED on PXI Module is Off When PXI Chassis is On If the ACCESS LED is not lit after you power on the PXI chassis, a problem may exist with the PXI power rails, a hardware device, or the LED. N...
Page 27 - Device Does Not Appear in MAX; Device Failed the Self-Test; I Received a Thermal Shutdown Error; kErrorDeviceShutDownDueToHighTemp
© National Instruments Corporation 27 NI Digital Waveform Generator/Analyzer Guide Device Does Not Appear in MAX Complete the following steps if the NI device does not appear in MAX: 1. In the MAX Configuration pane, click Devices and Interfaces to expand the category. 2. Click NI-DAQmx Devices and ...
Page 28 - Performance Issues Using MXI Connection; Start»Programs»National; Technical Support Resources; NI Web Support
NI Digital Waveform Generator/Analyzer Guide 28 ni.com Performance Issues Using MXI Connection When using a MXI connection to control the PXI chassis, the MXI Optimization Application must be run prior to using the NI device. By default, this application runs automatically when Windows starts. Use o...
Page 29 - your service request at
© National Instruments Corporation 29 NI Digital Waveform Generator/Analyzer Guide your service request at ni.com/support and follow the calling instructions or dial 512 795 8248. For telephone support outside the United States, contact your local branch office: Australia 1800 300 800, Austria 43 0 ...