Important Information Warranty The AT-MIO/AI E Series boards are warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that prov...
National Instruments Corporation v AT-MIO/AI E Series User Manual About This Manual Organization of This Manual ........................................................................................xiConventions Used in This Manual ...................................................................
Table of Contents AT-MIO/AI E Series User Manual vi National Instruments Corporation Chapter 3Hardware Overview Analog Input ................................................................................................................. 3-6 Input Mode ...............................................
Table of Contents AT-MIO/AI E Series User Manual viii National Instruments Corporation Appendix ASpecifications AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3 ................................................ A-1AT-MIO-16E-10 and AT-MIO-16DE-10 ............................................................
Table of Contents AT-MIO/AI E Series User Manual x National Instruments Corporation Figure B-1. 68-Pin MIO Connector Pin Assignments ................................................ B-2Figure B-2. 68-Pin DIO Connector Pin Assignments ................................................ B-3Figure B-3. ...
About This Manual National Instruments Corporation xi AT-MIO/AI E Series User Manual This manual describes the electrical and mechanical aspects of each board in the AT E Series product line and contains information concerning their operation and programming. Unless otherwise noted, text applies t...
About This Manual AT-MIO/AI E Series User Manual xii National Instruments Corporation • Chapter 4, Signal Connections, describes how to make input and output signal connections to your AT E Series board via the board I/O connector. • Chapter 5, Calibration, discusses the calibration procedures for...
About This Manual National Instruments Corporation xiii AT-MIO/AI E Series User Manual ♦ The ♦ indicates that the text following it applies only to specific AT E Series boards. <> Angle brackets containing numbers separated by an ellipsis represent a range of values associated with a bit, po...
About This Manual AT-MIO/AI E Series User Manual xiv National Instruments Corporation relevant pieces of the system. Consult these guides when you are making your connections. • SCXI chassis manuals—If you are using SCXI, read these manuals for maintenance information on the chassis and installati...
National Instruments Corporation 1-1 AT-MIO/AI E Series User Manual Introduction Chapter 1 This chapter describes the AT E Series boards, lists what you need to get started, describes the optional software and optional equipment, and explains how to unpack your AT E Series board. About the AT E Se...
Chapter 1 Introduction AT-MIO/AI E Series User Manual 1-2 National Instruments Corporation timing event. The AT E Series boards have the Real-Time System Integration (RTSI) bus to solve this problem. The RTSI bus consists of our RTSI bus interface and a ribbon cable to route timing and trigger sig...
Chapter 1 Introduction National Instruments Corporation 1-3 AT-MIO/AI E Series User Manual Software Programming Choices There are several options to choose from when programming your National Instruments DAQ and SCXI hardware. You can use LabVIEW, LabWindows/CVI, NI-DAQ, or register-level programm...
Chapter 1 Introduction National Instruments Corporation 1-5 AT-MIO/AI E Series User Manual You can use your AT E Series board, together with other PC, AT, EISA, DAQCard, and DAQPad Series DAQ and SCXI hardware, with NI-DAQ software for PC compatibles. Register-Level Programming The final option fo...
Chapter 1 Introduction AT-MIO/AI E Series User Manual 1-6 National Instruments Corporation Custom Cabling National Instruments offers cables and accessories for you to prototype your application or to use if you frequently change board interconnections. If you want to develop your own cable, howev...
Chapter 1 Introduction National Instruments Corporation 1-7 AT-MIO/AI E Series User Manual Unpacking Your AT E Series board is shipped in an antistatic package to prevent electrostatic damage to the board. Electrostatic discharge can damage several components on the board. To avoid such damage in ...
National Instruments Corporation 2-1 AT-MIO/AI E Series User Manual Installation and Configuration Chapter 2 This chapter explains how to install and configure your AT E Series board. Software Installation You may need to install your software before you install your AT E Series board. Refer to th...
Chapter 2 Installation and Configuration AT-MIO/AI E Series User Manual 2-2 National Instruments Corporation 1. Write down the AT E Series board serial number in the AT E Series Hardware and Software Configuration Form in Appendix D at the back of this manual. You will need this serial number when...
Chapter 2 Installation and Configuration National Instruments Corporation 2-3 AT-MIO/AI E Series User Manual Plug and Play The AT E Series boards are fully compatible with the industry-standard Plug and Play ISA specification. A Plug and Play system arbitrates and assigns resources through softwar...
Chapter 2 Installation and Configuration AT-MIO/AI E Series User Manual 2-4 National Instruments Corporation 16-bit DMA channels, which correspond to channels 5, 6, and 7 in an ISA computer and channels 0, 1, 2, 3, 5, 6, and 7 in an EISA computer. These selections are all software configured and d...
National Instruments Corporation 3-1 AT-MIO/AI E Series User Manual Hardware Overview Chapter 3 This chapter presents an overview of the hardware functions on your AT E Series board. Figure 3-1 shows the block diagram for the AT-MIO-16E-1 and AT-MIO-16E-2 Figure 3-1. AT-MIO-16E-1 and AT-MIO-16E-2 ...
Chapter 3 Hardware Overview AT-MIO/AI E Series User Manual 3-6 National Instruments Corporation Figure 3-6 shows a block diagram for the AT-MIO-16XE-50. Figure 3-6. AT-MIO-16XE-50 Block Diagram Analog Input The analog input section of each AT E Series board is software configurable. You can select...
Chapter 3 Hardware Overview National Instruments Corporation 3-7 AT-MIO/AI E Series User Manual programmed on a per channel basis for multimode scanning. For example, you can configure the circuitry to scan 12 channels—four differentially configured channels and eight single-ended channels. Table ...
Chapter 3 Hardware Overview AT-MIO/AI E Series User Manual 3-8 National Instruments Corporation You can program polarity and range settings on a per channel basis so that you can configure each input channel uniquely. The software-programmable gain on these boards increases their overall flexibili...
Chapter 3 Hardware Overview National Instruments Corporation 3-9 AT-MIO/AI E Series User Manual ♦ AT-MIO-16XE-10, AT-AI-16XE-10, AT-MIO-16XE-50 These boards have two input polarities—unipolar and bipolar. Unipolar input means that the input voltage range is between 0 and V ref , where V ref is a p...
Chapter 3 Hardware Overview AT-MIO/AI E Series User Manual 3-10 National Instruments Corporation Considerations for Selecting Input Ranges Which input polarity and range you select depends on the expected range of the incoming signal. A large input range can accommodate a large signal variation bu...
Chapter 3 Hardware Overview National Instruments Corporation 3-11 AT-MIO/AI E Series User Manual Dither When you enable dither, you add approximately 0.5 LSB rms of white Gaussian noise to the signal to be converted by the ADC. This addition is useful for applications involving averaging to increa...
Chapter 3 Hardware Overview AT-MIO/AI E Series User Manual 3-12 National Instruments Corporation Figure 3-7. Dither You cannot disable dither on the AT-MIO-16XE-10, AT-AI-16XE-10, or AT-MIO-16XE-50. This is because the resolution of the ADC is so fine that the ADC and the PGIA inherently produce a...
Chapter 3 Hardware Overview National Instruments Corporation 3-13 AT-MIO/AI E Series User Manual constant and source impedances are low. Refer to Appendix A, Specifications, for a complete listing of settling times for each of the AT E Series boards. When scanning among channels at various gains, ...
Chapter 3 Hardware Overview AT-MIO/AI E Series User Manual 3-14 National Instruments Corporation Analog Output ♦ AT-MIO-16E-1, AT-MIO-16E-2, AT-MIO-64E-3, AT-MIO-16E-10, AT-MIO-16DE-10 The AT E Series boards supply two channels of analog output voltage at the I/O connector. You can select the refe...
Chapter 3 Hardware Overview National Instruments Corporation 3-15 AT-MIO/AI E Series User Manual Selecting a bipolar range for a particular DAC means that any data written to that DAC will be interpreted as two’s complement format. In two’s complement mode, data values written to the analog output...
Chapter 3 Hardware Overview AT-MIO/AI E Series User Manual 3-16 National Instruments Corporation shown in Figure 3-8. The trigger-level range for the direct analog channel is ± 10 V in 78 mV steps for the AT-MIO-16E-1, AT-MIO-16E-2, and AT-MIO-64E-3, and ± 10 V in 4.9 mV steps for the AT-MIO-16XE-...
Chapter 3 Hardware Overview National Instruments Corporation 3-19 AT-MIO/AI E Series User Manual Digital I/O The AT E Series boards contain eight lines of digital I/O for general-purpose use. You can individually configure each line through software for either input or output. The AT-MIO-16DE-10 h...
Chapter 3 Hardware Overview AT-MIO/AI E Series User Manual 3-20 National Instruments Corporation Figure 3-14. CONVERT* Signal Routing This figure shows that CONVERT* can be generated from a number of sources, including the external signals RTSI<0..6> and PFI<0..9> and the internal sign...
Chapter 3 Hardware Overview National Instruments Corporation 3-21 AT-MIO/AI E Series User Manual You can also individually enable each of the PFI pins to output a specific internal timing signal. For example, if you need the UPDATE* signal as an output on the I/O connector, software can turn on th...
National Instruments Corporation 4-1 AT-MIO/AI E Series User Manual Signal Connections Chapter 4 This chapter describes how to make input and output signal connections to your AT E Series board via the board I/O connector. The I/O connector for the AT-MIO-16E-1, AT-MIO-16E-2, AT-MIO-16E-10, AT-MIO...
Chapter 4 Signal Connections National Instruments Corporation 4-5 AT-MIO/AI E Series User Manual I/O Connector Signal Descriptions Signal Name Reference Direction Description AIGND — — Analog Input Ground—These pins are the reference point for single-ended measurements and the bias current return ...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-16 National Instruments Corporation Analog Input Signal Connections ♦ AT-MIO-16E-1, ΑΤ -MIO-16E-2, AT-MIO-16E-10, AT-MIO-16DE-10, AT-MIO-16XE-10, AT-AI-16XE-10, AT-MIO-16XE-50 The analog input signals are ACH<0..15>, AISENSE, and ...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-18 National Instruments Corporation Types of Signal Sources When configuring the input channels and making signal connections, you must first determine whether the signal sources are floating or ground-referenced. The following sections...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-20 National Instruments Corporation Differential Connection Considerations (DIFF Input Configuration) A differential connection is one in which the AT E Series board analog input signal has its own reference signal or signal return path...
Chapter 4 Signal Connections National Instruments Corporation 4-21 AT-MIO/AI E Series User Manual Differential Connections for Ground-Referenced Signal Sources Figure 4-6 shows how to connect a ground-referenced signal source to an AT E Series board channel configured in DIFF input mode. Figure 4-...
Chapter 4 Signal Connections National Instruments Corporation 4-23 AT-MIO/AI E Series User Manual any resistors at all. This connection works well for DC-coupled sources with low source impedance (less than 100 Ω ). However, for larger source impedances, this connection leaves the differential sig...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-24 National Instruments Corporation Single-Ended Connection Considerations A single-ended connection is one in which the AT E Series board analog input signal is referenced to a ground that can be shared with other input signals. The in...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-26 National Instruments Corporation Figure 4-9 shows how to connect a grounded signal source to an AT E Series board channel configured for NRSE mode. Figure 4-9. Single-Ended Input Connections for Ground-Referenced Signal Common-Mode S...
Chapter 4 Signal Connections National Instruments Corporation 4-27 AT-MIO/AI E Series User Manual Analog Output Signal Connections The analog output signals are DAC0OUT, DAC1OUT, EXTREF, and AOGND. DAC0OUT and DAC1OUT are not available on the AT-AI-16XE-10. EXTREF is not available on the AT-MIO-16...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-28 National Instruments Corporation Figure 4-10 shows how to make analog output connections and the external reference input connection to your AT E Series board. Figure 4-10. Analog Output Connections The external reference signal can ...
Chapter 4 Signal Connections National Instruments Corporation 4-29 AT-MIO/AI E Series User Manual Warning: Exceeding the maximum input voltage ratings, which are listed in Tables 4-1 through 4-4, can damage the AT E Series board and the PC. National Instruments is NOT liable for any damages result...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-30 National Instruments Corporation Power Connections Two pins on the I/0 connector supply +5 V from the PC power supply via a self-resetting fuse. The fuse will reset automatically within a few seconds after the overcurrent condition i...
Chapter 4 Signal Connections National Instruments Corporation 4-31 AT-MIO/AI E Series User Manual external TRIG1 source and an external CONVERT* source to two of the AT E Series board PFI pins. Figure 4-12. Timing I/O Connections Programmable Function Input Connections There are a total of 13 inte...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-32 National Instruments Corporation detection requirements for each timing signal are listed within the section that discusses that individual signal. In edge-detection mode, the minimum pulse width required is 10 ns. This applies for b...
Chapter 4 Signal Connections National Instruments Corporation 4-33 AT-MIO/AI E Series User Manual Figure 4-14. Typical Pretriggered Acquisition SCANCLK Signal SCANCLK is an output-only signal that generates a pulse with the leading edge occurring approximately 50 to 100 ns after an A/D conversion ...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-34 National Instruments Corporation EXTSTROBE* signal. A 10 µ s and a 1.2 µ s clock are available for generating a sequence of eight pulses in the hardware-strobe mode. Figure 4-16 shows the timing for the hardware-strobe mode EXTSTROBE...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-36 National Instruments Corporation TRIG2 Signal Any PFI pin can externally input the TRIG2 signal, which is available as an output on the PFI1/TRIG2 pin. Refer to Figure 4-13 for the relationship of TRIG2 to the data acquisition sequen...
Chapter 4 Signal Connections National Instruments Corporation 4-37 AT-MIO/AI E Series User Manual Figure 4-20. TRIG2 Output Signal Timing STARTSCAN Signal Any PFI pin can externally input the STARTSCAN signal, which is available as an output on the PFI7/STARTSCAN pin. Refer to Figures 4-13 and 4-1...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-38 National Instruments Corporation Figures 4-21 and 4-22 show the input and output timing requirements for the STARTSCAN signal Figure 4-21. STARTSCAN Input Signal Timing Figure 4-22. STARTSCAN Output Signal Timing Rising-edgepolarity ...
Chapter 4 Signal Connections National Instruments Corporation 4-41 AT-MIO/AI E Series User Manual AIGATE Signal Any PFI pin can externally input the AIGATE signal, which is not available as an output on the I/O connector. The AIGATE signal can mask off scans in a data acquisition sequence. You can...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-42 National Instruments Corporation Either the 20 MHz or 100 kHz internal timebase generates the SISOURCE signal unless you select some external source. Figure 4-25 shows the timing requirements for the SISOURCE signal. Figure 4-25. SIS...
Chapter 4 Signal Connections National Instruments Corporation 4-45 AT-MIO/AI E Series User Manual UISOURCE Signal Any PFI pin can externally input the UISOURCE signal, which is not available as an output on the I/O connector. The UI counter uses the UISOURCE signal as a clock to time the generatio...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-46 National Instruments Corporation General-Purpose Timing Signal Connections The general-purpose timing signals are GPCTR0_SOURCE, GPCTR0_GATE, GPCTR0_OUT, GPCTR0_UP_DOWN, GPCTR1_SOURCE, GPCTR1_GATE, GPCTR1_OUT, GPCTR1_UP_DOWN, and FRE...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-52 National Instruments Corporation The GATE and OUT signal transitions shown in Figure 4-37 are referenced to the rising edge of the SOURCE signal. This timing diagram assumes that the counters are programmed to count rising edges. The...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-54 National Instruments Corporation This section lists the timing specifications for handshaking with the AT-MIO-16DE-10 port C circuitry. The handshaking lines STB* and IBF synchronize input transfers. The handshaking lines OBF* and AC...
Chapter 4 Signal Connections National Instruments Corporation 4-55 AT-MIO/AI E Series User Manual Mode 1 Input Timing The following are the timing specifications for an input transfer in Mode 1: Figure 4-38. Mode 1 Input Timing Name Description Minimum Maximum T1 STB* Pulse Width 100 – T2 STB* = 0...
Chapter 4 Signal Connections AT-MIO/AI E Series User Manual 4-58 National Instruments Corporation Field Wiring Considerations Environmental noise can seriously affect the accuracy of measurements made with your AT E Series board if you do not take proper care when running signal wires between sign...
National Instruments Corporation 5-1 AT-MIO/AI E Series User Manual Calibration Chapter 5 This chapter discusses the calibration procedures for your AT E Series board. If you are using the NI-DAQ device driver, that software includes calibration functions for performing all of the steps in the cal...
Chapter 5 Calibration AT-MIO/AI E Series User Manual 5-2 National Instruments Corporation This method of calibration is not very accurate because it does not take into account the fact that the board measurement and output voltage errors can vary with time and temperature. It is better to self-cal...
Chapter 5 Calibration National Instruments Corporation 5-3 AT-MIO/AI E Series User Manual To externally calibrate your board, be sure to use a very accurate external reference. The reference should be several times more accurate than the board itself. For example, to calibrate a 12-bit board, the ...
National Instruments Corporation A-1 AT-MIO/AI E Series User Manual Specifications Appendix A This appendix lists the specifications of each board in the AT E Series. These specifications are typical at 25 ° C unless otherwise noted. AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3 Analog Input Input C...
Appendix A Specifications for AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3 AT-MIO/AI E Series User Manual A-2 National Instruments Corporation Input coupling .................................... DC Max working voltage (signal + common mode)................. Each input should remain within ± 11 V of...
Appendix A Specifications for AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3 National Instruments Corporation A-3 AT-MIO/AI E Series User Manual Transfer Characteristics Relative accuracy ............................. ± 0.5 LSB typ dithered, ± 1.5 LSB max undithered DNL .................................
Appendix A Specifications for AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3 AT-MIO/AI E Series User Manual A-4 National Instruments Corporation Dynamic Characteristics Bandwidth ......................... Small signal (-3dB) Large signal (1% THD) AT-MIO-16E-1 1.6 MHz 1 MHz AT-MIO-16E-2, AT-MIO-64E-3 ...
Appendix A Specifications for AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3 National Instruments Corporation A-5 AT-MIO/AI E Series User Manual Crosstalk ........................................... -80 dB, DC to 100 kHz Stability Recommended warm-up time ............ 15 min Offset temperature coeffi...
Appendix A Specifications for AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3 National Instruments Corporation A-7 AT-MIO/AI E Series User Manual Gain error (relative to external reference)........... +0% to +0.5% of output max, not adjustable Voltage Output Ranges .......................................
Appendix A Specifications for AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3 AT-MIO/AI E Series User Manual A-8 National Instruments Corporation Onboard calibration reference Level .......................................... 5.000 V ( ± 2.5 mV) (actual value stored in EEPROM) Temperature coefficient ....
Appendix A Specifications for AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3 National Instruments Corporation A-9 AT-MIO/AI E Series User Manual Base clocks available Counter/timers ............................ 20 MHz, 100 kHz Frequency scalers........................ 10 MHz, 100 kHz Base clock accur...
National Instruments Corporation A-11 AT-MIO/AI E Series User Manual AT-MIO-16E-10 and AT-MIO-16DE-10 Analog Input Input Characteristics Number of channels ...........................16 single-ended or 8 differential, software selectable Type of ADC .....................................Successive ...
Appendix A Specifications for AT-MIO-16E-10 and AT-MIO-16DE-10 National Instruments Corporation A-17 AT-MIO/AI E Series User Manual Power-on state ................................... Input (High-Z) Data transfers AT-MIO-16E-10 ......................... Programmed I/O AT-MIO-16DE-10 ..................
Appendix A Specifications for AT-MIO-16E-10 and AT-MIO-16DE-10 AT-MIO/AI E Series User Manual A-18 National Instruments Corporation Power Requirement +5 VDC ( ± 5%)................................... 0.7 A Power available at I/O connector ....... +4.65 VDC to +5.25 VDC at 1 A Physical Dimensions (...
National Instruments Corporation A-19 AT-MIO/AI E Series User Manual AT-MIO-16XE-10 and AT-AI-16XE-10 Analog Input Input Characteristics Number of channels ...........................16 single-ended or 8 differential (software-selectable) Type of ADC .....................................Successive...
Appendix A Specifications for AT-MIO-16XE-10 and AT-AI-16XE-10 AT-MIO/AI E Series User Manual A-22 National Instruments Corporation Analog Output (AT-MIO-16XE-10 only) Output Characteristics Number of channels ........................... 2 voltage Resolution ..........................................
Appendix A Specifications for AT-MIO-16XE-10 and AT-AI-16XE-10 National Instruments Corporation A-23 AT-MIO/AI E Series User Manual Dynamic Characteristics Settling time for full-scale step.......... 10 µ s to ± 1 LSB accuracy Slew rate ........................................... 5 V/ µ s Noise .....
Appendix A Specifications for AT-MIO-16XE-10 and AT-AI-16XE-10 AT-MIO/AI E Series User Manual A-24 National Instruments Corporation Timing I/O Number of channels ........................... 2 up/down counter/timers, 1 frequency scaler Resolution Counter/timers ............................ 24 bits ...
Appendix A Specifications for AT-MIO-16XE-10 and AT-AI-16XE-10 National Instruments Corporation A-25 AT-MIO/AI E Series User Manual External input (PFI0/TRIG1) Impedance................................... 10 k Ω Coupling ..................................... DC Protection.............................
National Instruments Corporation A-26 AT-MIO/AI E Series User Manual AT-MIO-16XE-50 Analog Input Input Characteristics Number of channels ...........................16 single-ended or 8 differential (software-selectable) Type of ADC .....................................Successive approximation Res...
National Instruments Corporation C-1 AT-MIO/AI E Series User Manual Common Questions Appendix C This appendix contains a list of commonly asked questions and their answers relating to usage and special features of your AT E Series board. General Information 1. What are the AT E Series boards? The ...
Appendix C Common Questions AT-MIO/AI E Series User Manual C-2 National Instruments Corporation that some AT E Series boards have settling times that vary with gain and accuracy. See Appendix A for exact specifications. 4. What type of 5 V protection do the AT E Series boards have? The AT E Series...
Appendix C Common Questions National Instruments Corporation C-3 AT-MIO/AI E Series User Manual 10. What special calls must be made in DOS or LabWindows to use AT E Series boards? To link in the AT E Series function calls, you must call USE_E_Series or one of its subsets. 11. What is the best way ...
Appendix C Common Questions AT-MIO/AI E Series User Manual C-4 National Instruments Corporation 15. Can I sample across a number of channels on an AT E Series board while each channel is being sampled at a different rate? NI-DAQ for PC compatibles version 4.5.1 or later features a new function cal...
Appendix C Common Questions National Instruments Corporation C-5 AT-MIO/AI E Series User Manual b. Set up data acquisition timing so that the timing signal for A/D conversion comes from PFI5, as follows: • If you are using NI-DAQ, call Select_Signal(deviceNumber, ND_IN_CONVERT, ND_PFI_5, ND_HIGH_T...
Appendix C Common Questions AT-MIO/AI E Series User Manual C-6 National Instruments Corporation 20. What is the difference in timebases between the Am9513 counter/timer and the DAQ-STC? The DAQ-STC-based MIO boards have a 20 MHz timebase. The Am9513-based MIO boards have a 1 MHz or 5 MHz timebase....
Appendix C Common Questions National Instruments Corporation C-7 AT-MIO/AI E Series User Manual errors. NI-DAQ takes a snapshot of transfers and counts how many points have been transferred. If all the points have been transferred and the first instance of this error occurs, NI-DAQ returns a gpctr...
Appendix C Common Questions AT-MIO/AI E Series User Manual C-8 National Instruments Corporation a 50 k Ω pull-up resistor. This pull-up resistor will set the DIO(0) pin to a logic high when the output is in a high impedance state.
National Instruments Corporation D-1 AT-MIO/AI E Series User Manual Customer Communication Appendix D For your convenience, this appendix contains forms to help you gather the information necessary to help us solve your technical problems and a form you can use to comment on the product documentat...
FaxBack is a 24-hour information retrieval system containing a library of documents on a wide range of technical information. You can access FaxBack from a touch-tone telephone at (512) 418-1111. You can submit technical support questions to the appropriate applications engineering team through e-ma...
Technical Support Form Photocopy this form and update it each time you make changes to your software or hardware, and use the completed copy of this form as a reference for your current configuration. Completing this form accurately before contacting National Instruments for technical support helps ...
Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: AT-MIO/AI E Series User Manual Edition Date: May 1996 Part Number: 320517E-01 Please comment on the...
National Instruments Corporation G-1 AT-MIO/AI E Series User Manual Symbols % percent ± plus or minus ˚ degrees / per + positive of, or plus – negative of, or minus Ω ohms square root of +5V +5 VDC source signal Prefix Meaning Value p- pico- 10 - 12 n- nano- 10 - 9 µ - micro- 10 - 6 m- milli- 10 -...
National Instruments Corporation I -1 AT-MIO/AI E Series User Manual Index Symbols +5 V signal description, 4-6power connections, 4-30 A ACH<0..15> signal analog input connections, 4-16AT-MIO-16E-10 and AT-MIO-16DE-10 (table), 4-10 AT-MIO-16XE-10 and AT-AI-16XE-10 (table), 4-12 AT-MIO-16XE-5...
Index AT-MIO/AI E Series User Manual I -2 National Instruments Corporation analog input specifications AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3, A-1 to A-5 amplifier characteristics, A-3dynamic characteristics, A-4 to A-5input characteristics, A-1 to A-2stability, A-5transfer characteristics, A...
Index AT-MIO/AI E Series User Manual I -4 National Instruments Corporation DAC1OUT signal analog output connections, 4-27 to 4-28AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3 (table), 4-8 AT-MIO-16E-10 and AT-MIO-16DE-10 (table), 4-10 AT-MIO-16XE-10 and AT-AI-16XE-10 (table), 4-12 AT-MIO-16XE-50 (ta...
Index National Instruments Corporation I -9 AT-MIO/AI E Series User Manual AT-MIO-16XE-50 (table), 4-15description (table), 4-7 PFI6/WFTRIG signal AT-MIO-16E-1, AT-MIO-16E-2 and AT-MIO-64E-3 (table), 4-9 AT-MIO-16E-10 and AT-MIO-16DE-10 (table), 4-11 AT-MIO-16XE-10 and AT-AI-16XE-10 (table), 4-13 ...
National Instruments Manuals
-
National Instruments SCC-AI01
Manual
-
National Instruments USB-6008/6009
Manual
-
National Instruments 7334
Manual
-
National Instruments NI 9403E
Manual
-
National Instruments DIO 6533
Manual
-
National Instruments NI PCI-5114
Manual
-
National Instruments 1000DC
Manual
-
National Instruments 321518A-01
Manual
-
National Instruments NI 5672
Manual
-
National Instruments USB-9221
Manual
-
National Instruments PCI
Manual
-
National Instruments NI 9229
Manual
-
National Instruments 6211
Manual
-
National Instruments NI 9217
Manual
-
National Instruments NI USB-6009
Manual
-
National Instruments NI sbRIO-960x
Manual
-
National Instruments 6024E
Manual
-
National Instruments 3.x
Manual
-
National Instruments NI 784xR
Manual
-
National Instruments NI-Motion
Manual