Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100 Worldwide Offices Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 011 284 5011, Canada (Cal...
Important Information Warranty The SCXI-1127 and SCXI-1128 are warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves...
Compliance FCC/Canada Radio Frequency Interference Compliance* Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless communications from interference. The FCC places digital electronics into two classes. These classes are known as Class A (for use in industr...
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Canadian Department of Communications This Class B digital apparatus meets all requirements of the Canadian Interference-Ca...
Conventions The following conventions are used in this manual: < > Angle brackets that contain numbers separated by an ellipsis represent a range of values associated with a bit or signal name—for example, DBIO<3..0>. » The » symbol leads you through nested menu items and dialog box opti...
© National Instruments Corporation vii SCXI-1127/1128 User Manual Contents Chapter 1Installing and Configuring the SCXI-1127/1128 Installing the Software ................................................................................................... 1-2Installing the Hardware ......................
Contents © National Instruments Corporation ix SCXI-1127/1128 User Manual Glossary Index Figures Figure 1-1. Installing the SCXI-1127/1128 into an SCXI Chassis .......................... 1-4 Figure 1-2. 4-Slot Single-Chassis Installation ......................................................... 1-6 ...
Contents SCXI-1127/1128 User Manual x ni.com Figure 2-24. 8 × 16 Matrix Parts Locator Diagram ................................................... 2-27 Figure 2-25. 8 × 16 Matrix Schematic ....................................................................... 2-28 Figure 2-26. SCXI-1127/1128 Relay C...
© National Instruments Corporation 1-1 SCXI-1127/1128 User Manual 1 Installing and Configuring the SCXI-1127/1128 The SCXI-1127 and SCXI-1228 modules are high-voltage multiplexer/matrix modules. The SCXI-1127 is a high-density armature relay module. The SCXI-1128 is a high-density solid-state relay ...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-2 ni.com In a matrix configuration, you can expand the columns of the matrix using the HVAB-backplane adapter. For example, you can connect two SCXI-1127/1128 modules via the HVAB-backplane adapter to create a 4 × 1...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-3 SCXI-1127/1128 User Manual The NI-SWITCH and NI-DMM version 1.5 installation window offers three choices: • Install NI-DMM —Choose this selection if you want to install only the software for the DMM. • Ins...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-4 ni.com Installing the SCXI-1127/1128 Module into the SCXI Chassis You need the following items to complete the installation: • SCXI-1127/1128 • SCXI chassis • 1/8 in. flathead screwdriver Figure 1-1. Installing th...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-5 SCXI-1127/1128 User Manual Note When installing the SCXI-1127/1128 module in an SCXI chassis, the rightmost slot (when the chassis is viewed from the front) must be filled first, then fill the slot to the ...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-6 ni.com Single 4-Slot Chassis Configuration Refer to Figures 1-2 and 1-3 to make connections in the single 4-slot chassis configuration. Figure 1-2. 4-Slot Single-Chassis Installation 1 SCXI-1127/1128 Module 2 4-Sl...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-7 SCXI-1127/1128 User Manual Figure 1-3. 4-Slot Configuration Parts Locator Diagram 1. Install the 2-slot HVAB-backplane adapter behind slots 3 and 4. 2. Install additional 1-slot HVAB-backplane adapters beh...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-8 ni.com Single 12-Slot Chassis Configuration Refer to Figures 1-4 and 1-5 to make connections in the single 12-slot chassis configuration. Figure 1-4. 12-Slot Single-Chassis Installation 1 SCXI-1127/1128 Module 2 1...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-9 SCXI-1127/1128 User Manual Figure 1-5. 12-Slot Configuration Parts Locator Diagram 1. Install the 8-slot HVAB-backplane adapter behind slots 5 through 12. 2. Install additional 2-slot and 1-slot HVAB-backp...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-10 ni.com Connecting the SCXI-1127/1128 to the DMM in a Multichassis System The following sections describe how to configure the following multichassis configurations: • 4-slot and 4-slot multichassis configuration ...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-11 SCXI-1127/1128 User Manual Refer to Figure 1-6 to set up this multichassis configuration. Figure 1-6. 4-Slot to 4-Slot Multichassis Configuration Parts Locator Diagram 1. Install the HVAB-backplane adapte...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-12 ni.com 2. Connect the HV8-HV8 cable from the first chassis, normally the connector behind slot 1, to the HVAB connector (behind slot 4) of the next chassis. 3. Connect the SH9MD-9MD cable from the AUX OUT connect...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-13 SCXI-1127/1128 User Manual Refer to Figure 1-7 to set up this multichassis configuration. Figure 1-7. 4-Slot to 12-Slot Multichassis Configuration Parts Locator Diagram 1 2-Slot HVAB-Backplane Adapter 2 1...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-14 ni.com 1. Install the HVAB-backplane adapters and jumper blocks in the 12-slot chassis as described in steps 1 through 3 in Single 12-Slot Chassis Configuration . 2. Connect the HV8-HV8 cable from the first chass...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-15 SCXI-1127/1128 User Manual Refer to Figure 1-8 to set up this multichassis configuration. Figure 1-8. 12-Slot to 12-Slot Multichassis Configuration Parts Locator Diagram 1. Install the HVAB-backplane adap...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-16 ni.com Notes Do not connect the SH9MD-9MD cable to the 2-slot HVAB-backplane adapter. An SCXI-1127/1128 is required in slot 12 of each 12-slot chassis to establish communications with all the chassis in the syste...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-17 SCXI-1127/1128 User Manual 5. Connect the HV8-BAN4 cable from the DMM to the HVAB connector behind SCXI slot 4. 6. Connect the SH9MD-9MD cable from the DMM to the AUX IN connector. 7. You can install any ...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-18 ni.com DMM in PXI Slots 1 through 3 Configuration To install your DMM in PXI slots 1 through 3, follow these steps: 1. Install your DMM in any one of the PXI slots 1 through 3. 2. In the SCXI subsystem, install t...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-19 SCXI-1127/1128 User Manual • At least one other SCXI module other than the SCXI-1127/1128, installed in the chassis Consult the documentation for your SCXI chassis and other SCXI modules for additional in...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-20 ni.com 3. Attach the other end of the DAQ cable to the National Instruments DAQ device. 4. Check the installation. 5. Turn on the SCXI chassis. 6. Turn on the computer or reconnect it to your chassis. If you alre...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-21 SCXI-1127/1128 User Manual – SH9MD-9MD cable – 8-position HVAB plug – HV8-BAN4 cable • External DMM (if needed) • BAN2-WIRE kit (two kits needed for 4-wire), if not using the HV8-BAN4 cable • Cable or wir...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-22 ni.com Note For the system to function properly, it must be controlled by a DAQ device or NI 4021 switch controller, or be a 2000 Series SCXI chassis. Configuring and Self-Test Run Measurement & Automation Ex...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-23 SCXI-1127/1128 User Manual 2. You will see the chassis selected in the list. Display the list of modules in the chassis by clicking the + next to the Chassis icon. 3. Right-click the module you want to co...
Chapter 1 Installing and Configuring the SCXI-1127/1128 SCXI-1127/1128 User Manual 1-24 ni.com To remove a module or chassis, right-click the chassis or module you want to remove and select Delete . To test the chassis configuration, right-click the chassis and select Test . Safety Information The f...
Chapter 1 Installing and Configuring the SCXI-1127/1128 © National Instruments Corporation 1-25 SCXI-1127/1128 User Manual National Instruments for service and repair to ensure that its safety features are not compromised. When using the terminal block with high common-mode voltages, you must insula...
© National Instruments Corporation 2-1 SCXI-1127/1128 User Manual 2 Using the SCXI-1127/1128 This chapter discusses in detail the operation of the SCXI-1127/1128. There are two major modes of operation: multiplexer and matrix. A third mode of operation, independent mode, allows you to access advance...
Chapter 2 Using the SCXI-1127/1128 SCXI-1127/1128 User Manual 2-2 ni.com The SCXI-1331 terminal block consists of a shielded board with 84 screw terminals for easy connection to the SCXI-1127/1128 input connector. The SCXI-1331 is shown in Figure 2-1. Figure 2-1. SCXI-1331 Signal Connections Dependi...
Chapter 2 Using the SCXI-1127/1128 © National Instruments Corporation 2-3 SCXI-1127/1128 User Manual The SCXI-1127/1128 contains a safety interlocking mechanism that prevents high voltages from appearing on the input connector when a terminal block is not present. However, when a SCXI-1331 or SCXI-1...
Chapter 2 Using the SCXI-1127/1128 SCXI-1127/1128 User Manual 2-4 ni.com Figure 2-3 shows an example of a 2-wire configuration using the SCXI-1331 terminal block. The diagram shows the 2-wire terminal block connections for channels 2, 5, 24, and 27. Channel 2 measures a voltage source (V 1 ). The po...
Chapter 2 Using the SCXI-1127/1128 © National Instruments Corporation 2-5 SCXI-1127/1128 User Manual 1-Wire Channel Scanning Configuration The SCXI-1127/1128 has 64, 1-wire channels in the multiplexer mode that are available through the SCXI-1331 terminal block. Figure 2-4 shows the SCXI-1127/1128 c...
Chapter 2 Using the SCXI-1127/1128 SCXI-1127/1128 User Manual 2-6 ni.com Figure 2-5. 1-Wire Wiring Diagram Both channel 24 (V 1 ) and 59 (V 2 ) are measuring voltage sources. The positive terminal of these sources go to screw terminals labeled 24 and 59 respectively. The negative terminals or the co...
Chapter 2 Using the SCXI-1127/1128 © National Instruments Corporation 2-9 SCXI-1127/1128 User Manual negative screw terminals and sensed via 1B positive and negative screw terminals. Note OUT0± and OUT2± are also referred to as COM0± in a 4-wire configuration. 4-Wire versus 2-Wire Resistance Measure...
Chapter 2 Using the SCXI-1127/1128 SCXI-1127/1128 User Manual 2-10 ni.com current and the other for sensing the voltage developed across the resistor, as shown in Figure 2-9. Figure 2-9. Signal Connections for a 4-Wire Resistance Measurement Since ideally the impedance of the voltmeter is infinite, ...
Chapter 2 Using the SCXI-1127/1128 © National Instruments Corporation 2-11 SCXI-1127/1128 User Manual Figure 2-10. Mixed Mode Scanning with an SCXI-1331 You can scan the channels in any sequence you want. You can connect more than one SCXI-1127/1128 module together using the HVAB-backplane adapter f...
Chapter 2 Using the SCXI-1127/1128 SCXI-1127/1128 User Manual 2-12 ni.com SCXI-1127/1128. In its simplest form, hardware-timed scanning uses one triggering signal to advance the multiplexer to the next channel in the scan. This is called synchronous scanning . Note When using a DMM with the SCXI-112...
Chapter 2 Using the SCXI-1127/1128 SCXI-1127/1128 User Manual 2-14 ni.com Hardware-Timed Scanning Using a DMM When using a DMM with the SCXI-1127/1128, synchronous mode is the only mode in which the DMM and the SCXI-1127/1128 operate. The DMM issues a trigger to advance the multiplexer at regular in...
Chapter 2 Using the SCXI-1127/1128 © National Instruments Corporation 2-15 SCXI-1127/1128 User Manual The module to which you connected your external DMM trigger signals is referred to as the cabled module. If you add additional SCXI-1127/1128 modules to your system, it is not necessary to cable the...
Chapter 2 Using the SCXI-1127/1128 © National Instruments Corporation 2-17 SCXI-1127/1128 User Manual Software Scanning Unlike hardware scanning, software scanning does not use hardware-generated triggers. In software scanning, a list of channels kept by the software is scanned by selecting the desi...
Chapter 2 Using the SCXI-1127/1128 SCXI-1127/1128 User Manual 2-18 ni.com Figure 2-16. Temperature Measurement Wiring Diagram The SCXI-1331 contains a cold-junction temperature sensor (CJS). This sensor is a special channel on the SCXI-1127/1128 dedicated to measuring the ambient temperature of the ...
Chapter 2 Using the SCXI-1127/1128 © National Instruments Corporation 2-19 SCXI-1127/1128 User Manual NI-DAQ, use the Thermistor_Convert function. The VI takes the output voltage of the temperature sensor, the reference voltage, and the precision resistance and returns the thermistor temperature. Al...
Chapter 2 Using the SCXI-1127/1128 SCXI-1127/1128 User Manual 2-20 ni.com the best accuracy, while 1-wire provides the maximum channel count. Use the 4-wire configuration to eliminate the effects of lead resistance on the measurement. Since the lead resistance is typically small when compared with t...
Chapter 2 Using the SCXI-1127/1128 © National Instruments Corporation 2-21 SCXI-1127/1128 User Manual Figure 2-18 shows an example of the SCXI-1331 and SCXI-1127/1128 configured as a 1 × 32, 2-wire matrix. The diagram shows the 2-wire terminal block connections for channels 3, 15, 27 and OUT0. You c...
Chapter 2 Using the SCXI-1127/1128 SCXI-1127/1128 User Manual 2-22 ni.com Figure 2-19. SCXI-1332 Terminal Block The SCXI-1127/1128 installed with the SCXI-1332 provides you with an 4 × 8 matrix without any extra wiring except for hooking up your signals to the columns and rows of the matrix. Refer t...
Chapter 2 Using the SCXI-1127/1128 SCXI-1127/1128 User Manual 2-26 ni.com Figure 2-23. 8 × 8 Matrix Schematic To make a larger matrix, such as a 8 × 16 matrix, you must make both column and row expansions. Follow these instructions to build a larger matrix: 1. Expand the columns to the target number...
Chapter 2 Using the SCXI-1127/1128 © National Instruments Corporation 2-27 SCXI-1127/1128 User Manual 2. Expand the rows to the target number, 8 in this case, by connecting the columns of the appropriate number of 4 × 16 matrix blocks, two in this case, using matrix expansion cables. Figure 2-24 sho...
Chapter 2 Using the SCXI-1127/1128 SCXI-1127/1128 User Manual 2-28 ni.com Figure 2-25 shows the schematic of the 8 × 16 matrix shown in Figure 2-24. Figure 2-25. 8 × 16 Matrix Schematic Cable #6 Cable #1 Cab le #5 Cab le #3 Cab le #2 Cab le #4 Terminal Block Boundary SCXI-1127/SCXI-1332 #1 R0 R1 R2 ...
Chapter 2 Using the SCXI-1127/1128 © National Instruments Corporation 2-29 SCXI-1127/1128 User Manual Independent Mode The SCXI-1127/1128 powers up in independent mode. In this mode, you can close or open any switch on the module via NI-SWITCH to the SCXI-1127/1128. All software-controllable switche...
© National Instruments Corporation A-1 SCXI-1127/1128 User Manual A Specifications This appendix lists the specifications for the SCXI-1127/1128 modules. These specifications are typical at 25 ° C unless otherwise noted. SCXI-1127 Input Characteristics Number of relays availableas channels ............
Appendix A Specifications for SCXI-1127 SCXI-1127/1128 User Manual A-2 ni.com Channel to channel crosstalk ..................50 Ω termination 10 kHz .............................................≤ –70 dB 100 kHz ...........................................≤ –57.79 dB 1 MHz ...............................
Appendix A Specifications for SCXI-1127 © National Instruments Corporation A-3 SCXI-1127/1128 User Manual Physical Dimensions............................................. 3.0 by 17.2 by 20.3 cm (1.2 by 6.9 by 8.0 in.) Environment Operating temperature ..........................0 to 50 ° C Storage te...
Appendix A Specifications for SCXI-1128 © National Instruments Corporation A-5 SCXI-1127/1128 User Manual Dynamic Characteristics Maximum operating speed ..................... 1200 cycles/s Relay operate time (at 20 ° C) ................ 0.25 ms typical, 0.5 ms max Relay release time (at 20 ° C) ......
Appendix A Specifications for SCXI-1128 SCXI-1127/1128 User Manual A-6 ni.com Pollution Degree 2 Indoor use only
© National Instruments Corporation B-1 SCXI-1127/1128 User Manual B Accessories This appendix lists various National Instruments products you can use with your SCXI-1127/1128 module. • The SCXI-1331 terminal block has screw terminal connections for all channels, bank commons, analog bus, and trigger...
© National Instruments Corporation C-1 SCXI-1127/1128 User Manual C Customizing Your Module This appendix describes how to customize your SCXI-1127/1128 module for current-loop receiving. The SCXI-1127/1128 modules have plated through holes for transforming individual channels to current-to-voltage ...
© National Instruments Corporation D-1 SCXI-1127/1128 User Manual D SCXI-1127/1128 Front Connector This appendix contains connector diagrams for the SCXI-1127/1128 switch cards. The diagrams also show the signal names that are used when the modules are in 2-wire mode, 1-wire mode, 4-wire mode, and 4...
Appendix D SCXI-1127/1128 Front Connector SCXI-1127/1128 User Manual D-6 ni.com Table D-1. Front Connector Signal Description Signal Name Type Description +5 V(ISO) Output +5 VDC isolated source—Powers the temperature sensor on the terminal block GND Output Ground CJS ± Input Cold-junction Temperatu...
© National Instruments Corporation E-1 SCXI-1127/1128 User Manual E Common Questions This appendix addresses common questions you may have while using your SCXI-1127/1128 module. How fast can I scan with the SCXI-1127/1128 module? The fastest scan rate for the SCXI-1127 is 100 scans/s, and the faste...
Appendix E Common Questions SCXI-1127/1128 User Manual E-2 ni.com • If you use the SCXI-1127/1128 to initiate the scan, make sure the DMM is waiting for a trigger before enabling scanning on the SCXI-1127/1128. • If you use the DMM to initiate the scan, enable scanning on the SCXI-1127/1128 before c...
Appendix E Common Questions © National Instruments Corporation E-3 SCXI-1127/1128 User Manual behind slots 3 and 4 you have connected the rows between slot 3 and 4 which creates a 4 × 16 matrix. Now install the two 1-slot adapters behind slots 1 and 2. Connect the two 1-slot adapters together with a...
© National Instruments Corporation F-1 SCXI-1127/1128 User Manual F Technical Support Resources Web Support National Instruments Web support is your first stop for help in solving installation, configuration, and application problems and questions. Online problem-solving and diagnostic resources inc...
Appendix F Technical Support Resources SCXI-1127/1128 User Manual F-2 ni.com Worldwide Support National Instruments has offices located around the world to help address your support needs. You can access our branch office Web sites from the Worldwide Offices section of ni.com . Branch office Web sit...
© National Instruments Corporation G-1 SCXI-1127/1128 User Manual Glossary Prefix Meanings Value n- nano- 10 – 9 µ- micro- 10 – 6 m- milli- 10 – 3 k- kilo- 10 3 M- mega- 10 6 G- giga- 10 9 Symbols ° degrees Ω ohms % percent ± plus or minus A A amperes AC alternating current ADE application developme...
Glossary SCXI-1127/1128 User Manual G-2 ni.com C C Celsius channel pin or wire lead on the multiplexer to which you apply or from which you read the analog or digital signal. Signals can be single-ended or differential. CJS cold junction sensor cold-junction compensation a method of compensating for...
Glossary SCXI-1127/1128 User Manual G-6 ni.com W W watts wire data path between nodes
© National Instruments Corporation I-1 SCXI-1127/1128 User Manual Index Numbers 1-wire channel scanning configuration, 2-5 to 2-6 block diagram, 2-5wiring diagram, 2-6 1_WIRE_LO_REF signal description (table), D-6one-wire channel scanning configuration, 2-5 to 2-6 2-wire channel scanning configurati...
National Instruments Manuals
-
National Instruments SCC-AI01
Manual
-
National Instruments USB-6008/6009
Manual
-
National Instruments 7334
Manual
-
National Instruments NI 9403E
Manual
-
National Instruments DIO 6533
Manual
-
National Instruments NI PCI-5114
Manual
-
National Instruments 1000DC
Manual
-
National Instruments 321518A-01
Manual
-
National Instruments NI 5672
Manual
-
National Instruments USB-9221
Manual
-
National Instruments PCI
Manual
-
National Instruments NI 9229
Manual
-
National Instruments 6211
Manual
-
National Instruments NI 9217
Manual
-
National Instruments NI USB-6009
Manual
-
National Instruments NI sbRIO-960x
Manual
-
National Instruments 6024E
Manual
-
National Instruments 3.x
Manual
-
National Instruments NI 784xR
Manual
-
National Instruments NI-Motion
Manual