Page 3 - The Basics; Installation; Installation – Circuit with 1 Switch; In the Box
Page 3 of 15 Rev: 1/21/2014 7:29 AM The Basics Cautions and Warnings Read and understand these instructions before installing and retain them for future reference. This product is intended for installation in accordance with the National Electric Code and local regulations in the United States or th...
Page 4 - SwitchLinc and its connected load will turn on; Installation – Circuit with 2 Switches
Page 4 of 15 Rev: 1/21/2014 7:29 AM 7) Turn off power 8) Connect wires as per table/diagram (confirm firm attachments with no exposed wire) If you are installing SwitchLinc in a multi-gang box next to another switch, you may need to remove one or both pairs of metal heatsink tabs on the back of Swit...
Page 5 - Both SwitchLincs and the connected load will remain in synch; Installation – Circuit with 3 (or more) Switches
Page 5 of 15 Rev: 1/21/2014 7:29 AM 13) Connect SwitchLinc white wire to neutral wire(s) in wall box (usually white) 14) Connect SwitchLinc red wire to load wire 15) Connect SwitchLinc black wire to same color traveler from Box 1 carrying Line (usually black) 16) Cap unused traveler wire 17) With LE...
Page 6 - Local Control; Tap for ON, press and hold to brighten
Page 6 of 15 Rev: 1/21/2014 7:29 AM In Box 2 (Traveler box) 12) Connect SwitchLinc bare wire to ground 13) Connect SwitchLinc white wire to neutral 1 14) Cap SwitchLinc red wire 15) Connect SwitchLinc black wire to same color traveler from Box 1 that you connected to line along with same color trave...
Page 7 - INSTEON Setup; INSTEON Controllers, Responders and Links; Controller LED will start blinking
Page 7 of 15 Rev: 1/21/2014 7:29 AM INSTEON Setup Some products have subtle differences in their setup procedures. Where necessary, please refer to the other device’s owner’s manual for details. INSTEON Controllers, Responders and Links Let’s define a few terms. • Each INSTEON compatible product is ...
Page 8 - Make SwitchLinc a Controller
Page 8 of 15 Rev: 1/21/2014 7:29 AM SwitchLinc will turn on (at desired brightness) and off Make SwitchLinc a Controller 1) Press and hold SwitchLinc Set button until it beeps LED will start blinking green 2) Adjust responder to desired brightness/state 3) Press and hold responder Set button until i...
Page 9 - Remove SwitchLinc as a Controller (Unlink); Accessories page on; Using Air Gap
Page 9 of 15 Rev: 1/21/2014 7:29 AM 7) Test by tapping controller button on and off SwitchLinc and all scene responders will turn on (to desired brightness/states) and off Remove SwitchLinc as a Controller (Unlink) 1) Press and hold SwitchLinc Set button until it beeps LED will start blinking green ...
Page 10 - SwitchLinc ships with no X10 address assigned.; Add X10 Address; Local Settings; To set local on-level to a fixed brightness level
Page 10 of 15 Rev: 1/21/2014 7:29 AM 4) When long beep stops, release Set button A few seconds will pass SwitchLinc will double-beep The connected load will turn on X10 Setup SwitchLinc ships with no X10 address assigned. Add X10 Address 1) Turn SwitchLinc on. 2) Press and hold Set button until it b...
Page 11 - Local Ramp Rate
Page 11 of 15 Rev: 1/21/2014 7:29 AM 2) Tap Set button SwitchLinc will beep 3) Test: a. Brighten SwitchLinc to a random brightness level (e.g. 75%) b. Turn SwitchLinc off c. Turn SwitchLinc back on Light will turn on at the defined brightness level Local Ramp Rate Default = ½ second. The local ramp ...
Page 12 - Error Blink; Specifications
Page 12 of 15 Rev: 1/21/2014 7:29 AM Error Blink Default = on. This setting is adjustable via software or a central controller only. SwitchLinc LED blinks for a few seconds if one or more responders do not acknowledge a message. Specifications General Product name SwitchLinc Dimmer High Wattage Bran...
Page 13 - Troubleshooting; Problem
Page 13 of 15 Rev: 1/21/2014 7:29 AM X10 status response Supported X10 resume dim Supported (by setting local on-level to zero) X10 minimum transmit level 3.2 Vpp into 5 Ohms X10 minimum receive level 20mV into 5 Ohms Mechanical Mounting Mounts in single or multiple-ganged junction box. Control 200W...
Page 15 - Certification and Warranty
Page 15 of 15 Rev: 1/21/2014 7:29 AM Certification and Warranty Certification This product has been thoroughly tested by ITS ETL SEMKO, a nationally recognized independent third-party testing laboratory. The North American ETL Listed mark signifies that the device has been tested to and has met the ...