Page 2 - Trademarks; Legal Notices
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Seiko Epson Corporation. The information contained here...
Page 3 - Contents
3 3 Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Handling and Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Setting Up the SpectroProofer . . . . . . . . . . . . . . 7 Unpacking and Assembly . . . . . . . . . . . . . . . . . . ...
Page 4 - C o n t e n t s
Page 5 - Handling and Product Information; Introduction
5 5 The EPSON SpectroProofer ® is an optional in-line color measuring system that can be installed on the EPSON Stylus ® Pro 7890, 7900, 9890, and 9900 printers. When driven by the latest software RIP front-ends, the SpectroProofer can automate virtually any color management process in your workflow...
Page 6 - I n t r o d u c t i o n
Page 7 - Unpacking and Assembly; OR
7 7 Follow the steps in this section to install the SpectroProofer in your printer. Before using the SpectroProofer for the first time, you must also initialize it as described on page 19. Unpacking and Assembly Unpack the SpectroProofer and make sure you have all the parts shown below: Setting Up t...
Page 8 - S e t t i n g U p t h e S p e c t r o P r o o f e r; presser and remove its packing material.
8 8 | S e t t i n g U p t h e S p e c t r o P r o o f e r 1. Remove any tape and protective material from the outside surface of the SpectroProofer. 2. Remove any tape from the paper presser, shown below. Raise the paper presser and remove its packing material. 3. Remove any packing tape from the ca...
Page 9 - Remove the packing material from the cables on the carriage.
9 S e t t i n g U p t h e S p e c t r o P r o o f e r | 9 4. Remove the packing material from the cables on the carriage. 5. Slide the carriage a little to the left and then remove its plastic retainer. 6. Slide the carriage back to the right, then lower the paper presser. Note: Save the retainer al...
Page 10 - Slide the carriage against the paper presser to lock it in place.
10 1 0 | S e t t i n g U p t h e S p e c t r o P r o o f e r 7. Slide the carriage against the paper presser to lock it in place. 8. Insert the spectrophotometer into the carriage so it clicks into place and then insert the two alignment pins. Caution: Make sure the alignment pins are flush with the...
Page 11 - Connect the cables on the carriage to the spectrophotometer.; Installing the SpectroProofer; User’s Guide
11 S e t t i n g U p t h e S p e c t r o P r o o f e r | 1 1 9. Connect the cables on the carriage to the spectrophotometer. Installing the SpectroProofer Before installing the SpectroProofer, make sure the printer has the latest firmware installed. Follow the instructions for upgrading firmware usi...
Page 12 - the two locations shown below.
12 1 2 | S e t t i n g U p t h e S p e c t r o P r o o f e r 3. Using the included bolts and Allen wrench, install the mounting rails in the two locations shown below. 4. Select whether you want to use the white or black backing plate(s). To attach a plate, align the tabs at the top of the plate wit...
Page 15 - Connecting the Cables; Open the cover on the right side of the SpectroProofer.
15 S e t t i n g U p t h e S p e c t r o P r o o f e r | 1 5 Connecting the Cables The 44" SpectroProofer has a secondary USB port that can be used to connect the optional Auto Take-up Reel (available for the EPSON Stylus Pro 9890 and 9900 only). The 24" SpectroProofer does not have this por...
Page 16 - Then close the cover.
16 1 6 | S e t t i n g U p t h e S p e c t r o P r o o f e r 3. Route the cable(s) through the channels and over the hook as shown. Then close the cover. 4. Attach two cable hooks to the right leg of the printer stand. Place the cable(s) in the hooks as shown, and snap the hooks closed. Warning: Mak...
Page 18 - stand. Place the power cord in the hook, and snap the hook closed.
18 1 8 | S e t t i n g U p t h e S p e c t r o P r o o f e r 7. Attach the remaining cable hook to the inside left leg of the printer stand. Place the power cord in the hook, and snap the hook closed. 8. Plug the power cord into a grounded electrical outlet and then plug the printer back into its AC...
Page 19 - Initializing the SpectroProofer
19 S e t t i n g U p t h e S p e c t r o P r o o f e r | 1 9 Initializing the SpectroProofer The SpectroProofer must be aligned before you use it for the first time. You only need to perform this procedure once. You don’t need to repeat the alignment if you remove and re-install the SpectroProofer. ...
Page 21 - Removing the SpectroProofer; Turn off the printer and unplug the power cord.
21 21 Follow the instructions in this chapter to clean the SpectroProofer. Cleaning may be necessary if you notice unusual color measurement results, which may be caused by dust or other contamination. This chapter also tells you how to respond to error messages and how to contact Epson for help. Re...
Page 22 - M a i n t e n a n c e a n d P r o b l e m S o l v i n g; Slide the SpectroProofer out of the printer.
22 2 2 | M a i n t e n a n c e a n d P r o b l e m S o l v i n g 3. Open the cover on the right side of the SpectroProofer and disconnect the cable(s). 4. Slide the SpectroProofer out of the printer. 5. Set the SpectroProofer on a flat surface to avoid damaging the lens. Note: The 24” model has only...
Page 23 - Cleaning the SpectroProofer
23 M a i n t e n a n c e a n d P r o b l e m S o l v i n g | 2 3 6. Unplug the cables from the spectrophotometer, and remove the spectrophotometer from the carriage. Cleaning the SpectroProofer You may need to clean the SpectroProofer if you notice unusual color readings. Check the following parts a...
Page 24 - spectrophotometer lens.
24 2 4 | M a i n t e n a n c e a n d P r o b l e m S o l v i n g 2. Use a can of compressed air designed for optical equipment to clean the spectrophotometer lens. 3. Remove the tile holder from the printer. 4. Remove the calibration tile from the holder. Caution: Do not touch the lens directly, or ...
Page 26 - mild detergent. Then use another cloth to wipe it dry.
26 2 6 | M a i n t e n a n c e a n d P r o b l e m S o l v i n g 8. Clean the paper presser using a soft, lint-free cloth dampened with a mild detergent. Then use another cloth to wipe it dry. 9. Lower the paper presser, then slide the carriage against it to lock it in place. 2 1
Page 27 - Error Messages; Message
27 M a i n t e n a n c e a n d P r o b l e m S o l v i n g | 2 7 Error Messages If a problem occurs with the SpectroProofer, you may see a message on the printer’s LCD screen. Check the following list for an explanation and instructions for solving the problem: Message Explanation Response ILS20EP D...
Page 29 - Recertification; Where To Get Help
29 M a i n t e n a n c e a n d P r o b l e m S o l v i n g | 2 9 Recertification The ISO Standards Committee recommends that all spectrophotometers be recertified each year. This recertification process is not covered under warranty or maintenance agreement. If maintained properly, your EPSON Spectr...
Page 31 - General; Spectrophotometer; Specifications
31 31 General Temperature Operation: 50 to 95°F (10 to 35°C) Storage (packed): –4 to 140°F (–20 to 60°C); less than 120 hours at 140°F (60°C); less than 1 month at 104°F (40°C) Storage (unpacked): –4 to 104°F (–20 to 40°C); less than 1 month at 104°F (40°C) Humidity Operation: 30 to 80% without cond...
Page 32 - S p e c i f i c a t i o n s; Electrical
32 3 2 | S p e c i f i c a t i o n s Measurement range 0 to 150% R (reflection) Repetition precision Max 0.2 dE cmc (white tile) Max 0.8 dE cmc (black tile) Instrument error Ave 0.5 dE cmc (12BCRA tile ILS20EP standard) Ave 1.0 dE cmc (12BCRA tile ILS20EP standard) Electrical Rated voltage AC 100 to...
Page 33 - Important Safety Instructions; FCC Compliance Statement; For United States Users; Notices
33 33 Important Safety Instructions Read all of these instructions before using your product. Also be sure to follow all warnings and instructions marked on the product. • Do not block or cover the openings in the product’s cabinet. • Do not insert objects through the slots. Take care not to spill l...
Page 34 - N o t i c e s; WARNING; Warranty
34 3 4 | N o t i c e s WARNING The connection of a non-shielded equipment interface cable to this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits established by the FCC for this equipment. It is the responsibility of the user t...