CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 2 For Safe and Correct Use To prevent injury to the user or damage to property, this guide gives information for the safe and correct use of this product. Before installation, operation, maintenance, or inspection, be su...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 3 Contents 1. Product Outline 1.1 ··· Features ··········································································································· 5 1.2 ··· Configuration ·········································...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 5 1. Product Outline 1.1. Features The Canon Digital Galvano Scanner System is fully digitally controlled with a high-precision optical encoder on the galvano motor and a high-speed digital signal processor (DSP) on the ...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 6 2. Specifications 2.1. Galvano Motor (KP-1SM30, KP-1SM100) Performance and shape KP-1SM30 KP-1SM100 Conforming beam diameter Φ 10 to φ 20 Φ 20 to φ 30 Scan angle ±20 deg ±20 deg Number of encoder pulses 83328 pulse...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 8 2.3. Outline Drawing KP-1SM30 KP-1SM100 ( 126.2 ) 37 11.5 7.5 φ 56 0 φ 6.35 -0.01 φ 34 φ 36h7 Motor Cable Encorder Cable Φ 48 Thermistor Cable 3-M4 Depth 8 TBD
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 10 2.4. Power Supply Power supply specifications +24 V ± 10% 10 A (max) × 2 axes (For motor drive) +5 V ± 5% 2.8 A (For control circuit) 2.5. Connections IF board Encoder SignalBoard Axis1 Axis2 +24V power +5V power High...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 11 2.6. Connector Pin Arrangement (Connector types) ① Axis 1 motor encoder ② Axis 2 motor encoder ③ +5 V power supply ④ +24 V power supply ⑤ RS-232C ⑥ High-speed serial communication ⑦ Digital input/output ⑧ Anal...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 13 ⑥ High-speed Serial Communication Connector model number Connector Model No. Manufacturer Board side SM12B-PASS-1-TB JST Cable side PAP-12V-S JST Connector pin arrangement Pin No. Signal Name Signal Description 1 CLK...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 14 ⑨ Fan Power Supply Connector model number Connector Model No. Manufacturer Board side S04B-PASK-2 JST Cable side PAP-04V-S JST Connector pin arrangement Pin No. Signal Description 1 +24 V Output 2 GND 2 Fan Rotation ...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 15 2.7. Control Specifications The controller (GC-201, GC-101) is operated by: • RS-232C command input • High-speed serial communication In addition, either the internal clock or external clock (high-speed serial communi...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 17 (Command specifications) In response to command send, the controller returns a reply with data. The data contents depend on the command. (For details, see 7-2, “Command Details.”) Command send A Axis No. C Command ID ...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 18 Parameter of controller can be changed by the following sending method to controller. Also in response to parameter send, the controller always returns a reply with data. The data contents depend on the command. (For ...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 19 For the ROM Write of the parameter, a reply with data has been sent by all means by a controller. The content of data is different by a parameter. (For details, see 7-3, “Parameter Details.”) ( Note ) Please make the ...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 22 (Target Position Data) XDAT 、 YDAT The data length of the target position data by the high-speed serial communication can be changed by two following parameters. The target position data length can be changed in 16b...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 23 Parameter ID = 67 20 Parameter ID = 68 0 With the default settings at shipping, the setting is ※ (16bit position data length, data least significant bit 1bit position). This communication specification has com...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 24 ( Status ) STS The status of controller is sent by status line (STS) of high-speed serial communication. The contents of status sending from a controller can be changed by the following parameter. Parameter ID Data 6...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 25 INPOS : In-position signal (When current position moves into the in-position width, this signal will be output.) 2: Current position (Axis 1) Output the Axis 1 encoder position. Position Data length: 20...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 26 2.8. Heat Radiation and Installation Since the controller and motor generate heat, their heat radiation should be considered carefully. Generated heat depends on the operating conditions. Determine a heat radiation me...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 27 3. Software The controller (GC-201, 101) comes with dedicated control software “GALILEO (Galvano Integrated Leading Operator (GALILEO).” GALILEO makes the following controller operations easy: ・ Parameter setting ・ Se...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 32 3.4. Control Screen This section explains the buttons and other items on the control screen. ① Connection display The status of RS-232 connection to the controller is displayed. Connected: CONNECT (green) Not connect...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 34 4. Operating Procedure This chapter explains how to use the system. Operations by [GALILEO] and by [RS-232C command] are explained together. 4.1. Controller Activation When the power (+5 V, +24 V) is turned on, the co...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 36 4.2. Step Movement Execute step movement for a fixed angle. GALILEO ・ Select the Step Move tab. ① ・ Select an axis for step movement. ② ・ Specify the displacement (angle and pulse count) for relative position (STEP) a...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 37 4.3. Raster Scan Execute oscillation of a fixed angle at a fixed frequency. GALILEO ・ Select the Raster Scan tab. ① ・ Select an axis for raster scan. ② ・ Specify the operation parameters (Scan Time, Scan Angle, and Du...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 38 4.4. Position Command Input by High-speed Serial Communication For a vector scan, give target position data to the controller by high-speed serial communication, The data is updated as required. Switch the controller ...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 39 5. Monitor Output and Digital Input Functions The controller has an analog monitor output connector for monitoring the operation status and a digital I/O connector for external signal input. 5.1. Connector Pin Arrange...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 40 The signal name is displayed on the evaluation monitor board. Please check the signal after referring to the table of the following pin arrangement. Analog monitor output connector Connector model number Connector Mod...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 41 Digital I/O connectors Connector model number Connector Model No. Manufacturer Board side 8931E-020-178L KEL Cable side 8925E-020-179 KEL Connector pin arrangement Pin No. Monitor board Signal Name I/O Signal Descript...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 42 5.2. Analog Monitor Output Selecting The analog monitor output can be switched to monitor various operation and signal statuses. This switching can be executed from [GALILEO] or [RS-232C command send] . Output content...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 43 GALILEO ・ Select the Monitor tab. ① ・ Select an axis for monitor output switching. ② ・ Select the monitor item of each output terminal. ③ ・ Select an output signal magnification. ④ ・ Press the SET button. ⑤ ① ③ ④ ⑤ ②
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 45 5.3. Digital Input-Output Function The controller has a digital input-output function for checking the status of the controller. Pin No. I/O Signal Description Logic Explanation A1 Output Axis 1 Error 1 (Priority high...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 46 6. Other - Operation Setting 6.1. Setting Controller Activation Mode Clock selection With the default settings at shipping, a parameter is set to activate the controller with the internal clock. When assembling the de...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 48 6.2. Operation that synchronizes with external trigger Signal input(Raster Scan) “4-3. raster scan operation”, It can be operated synchronizing with external trigger Signal. 【 The Movement Pattern 】 There are two kind...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 49 【 Input the external trigger signal 】 The external trigger signal is input from the digital I/O connector. ( See 5-1 ‘Connector Pin Arrangement ) Connector pin arrangement Pin NO. Monitor Board Signal Name I/O Signal ...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 50 7. Commands The controller has a monitor output (analog output) terminal for monitoring the RS-232C command operation status and an external signal input terminal for controller operation. 7.1. List of Commands ID Com...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 52 7.2. Command Details Command ID 0 Command Name Soft Reset Data 0: Reset + Automatic homing 1: Reset only Return Value 0: Command execution successful 1: Command execution unsuccessful Explanation This command resets t...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 58 Command ID 22 Command Name Target Velocity Setting Data Target velocity (Unit: pulse/s) Return Value 0: Command execution successful 1: Command execution unsuccessful Explanation This command is used to set the maximu...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 64 8. Parameters 8.1. List of Parameters ID Parameter Name 0 CW Limit 1 CCW Limit 2 Max Velocity 3 In-position Width 4 Settling Check Time 5 In-position Overtime 6 LQ Control Gain 7 Torque Constant 8 Total Inertia 9 Curr...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 66 8.2. Parameter Details Parameter ID 0 Parameter Name CW Limit Data Movable range (Unit: pulse) Return Value 0: Parameter setting successful 1: Parameter setting unsuccessful Explanation Specify the limit of the clockw...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 82 8.3. Modifying Parameters This section explains how to modify parameters. GALILEO ・ Select the All Parameter tab. ① ・ Select an axis for parameter settings. ② ・ The current parameter values are displayed. ③ ・ ...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 83 8.4. Writing Parameters into ROM All parameters are written in the controller ROM. At activation, the parameters are automatically read and set in the controller. If parameters are modified, they should be written int...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 84 8.5. Saving a Parameter File All parameters can be saved into a PC file. Save a parameter file as follows: ・ Select the All Parameter tab. ① ・ Select an axis for parameter settings. ② ・ The current parameter val...
CANON Digital Galvano Scanner System KP-1SM Series + GC-251 Users Manual 1.00 85 9. Safety Functions This system has various safety functions to ensure safe use. 9.1. Safety Functions The safety functions can be classified into hardware monitoring and software monitoring. Hardware monitoring ・ Pow...
Canon Inc. Canon Marketing Japan Inc. 2-16-2, Konan, Minato-ku, Tokyo 108-8011 CB Sales Department Tel. 03-3740-3336 ・ The contents of this document are subject to change without notice. ・ If you find any question, error, or omission in this document, please contact Canon. CUD-L007...
Manual Canon GC-201
Summary
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 3 Contents 1. Product Outline ............................................................................................................................. 5 1.1. Features .............................................................
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 5 1. Product Outline 1.1. Features The Canon Digital Galvano Scanner System is fully digitally controlled with a high-precision optical encoder on the galvano motor and a high-speed digital signal processor (DSP) on the controller...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 6 2. Specifications 2.1. Galvano Motor (GM-1010, GM-1015, and GM-1020) Performance and shape GM-1010 GM-1015 GM-1020 Conforming beam diameter Φ 8 to φ 10 φ 10 to φ 15 φ 15 to φ 30 Scan angle ±20 deg ±20 deg ±20 deg Encoder cycle n...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 11 2.4. Power Supply Power supply specifications +24 V ± 10% (For motor drive) Peak 10 A × 2 axes RMS 2.5 A × 2 axes (RMS value differs according to operating conditions, the above conditions GM-1010, Ymirror 、 ±5°, 200Hz) +5 V ± ...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 14 (Connector model number & pin assignment) ③ +5 V power supply (Connector model number) Connector Model No. Manufacturer Board side S2P-VH JST Cable side VHR-2N JST (Connector pin assignment) Pin No. Signal Description 1 +5 ...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 16 ⑨ Cooling Fan Power Supply (Connector model number) Connector Model No. Manufacturer Board side S04B-PASK-2 JST Cable side PAP-04V-S JST (Connector pin arrangement) Pin No. Signal Description 1 +24 V Output 2 GND 3 (No connecti...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 18 ③ RS-232C Cable PC side (D-sub 9 pin) Pin Signal 2 RX 3 TX 5 GND ④ High-Speed Serial Communication Cable PC side (D-sub 25pin) Pin Signal Pin Signal 1 Clock - 14 Clock + 2 FS - 15 FS + 3 Data (Axis 1) - 16 Data (Axis 1) + 4 Dat...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 20 - With the default settings at shipping, power-on starts up the controller with in RS-232 Communication Command Input mode. - The parameter can be set to determine which mode the controller starts after power-on. (See 6.1. “Set...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 21 2.8.1. Number of Encoder Pulses This section explains the relationship between the galvano scanner motor rotating angle and the number of encoder pulses. Control commands and some of the parameter angle settings use the number ...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 23 (Command specifications) In response to command send, the controller returns a reply with data. The data contents depend on the command. (For details, see 8.2. “Command Details”) Command send A Axis No. C Command ID / Data Deli...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 24 Parameters of the GC-201 can be changed by the following sending method to the controller. Also in response to parameters sent, the controller always returns a reply with data. The data contents depend on the command. (For deta...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 25 Writing parameters to ROM is also possible with commands via RS-232C. When writing parameters to ROM, a reply that definitely contains data will be sent by a controller. The content of data is different by a parameter. (For det...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 31 • In the case of 20 bit data Usually data 1 = 1 pulse. (GM-1010) High-speed communication Target position data value 20bit Motor Number of pluses Motor rotating angle Maximum position 0xFFFFF - 524287 pulses - 23.04 deg 0 pulse...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 33 2.8.3.2. High-speed serial communication motor drive timing The following diagram indicates actual motor drive signal output timing when the high-speed serial communication position command is received. COMMAND XY-2 COMMAND FRA...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 34 2.8.4. Status (High-speed Serial Communication STS) The controller status is sent by the high-speed serial communication STS line. The contents of status sent from a controller can be changed by the following parameter. Note: S...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 37 2.8.5. RS-232C Communication Command Input and High-Speed Communication Switching A position command input can be switched with a RS-232C communication command. Command ID Data 23 0: RS-232C command communication 7: High-speed ...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 38 2.9. Heat Radiation and Installation Since the controller and motor generate heat, their heat radiation should be considered carefully. Generated heat depends on the operating conditions. Determine a heat radiation method accor...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 39 3. Software The controller (GC-201) bundles the dedicated control software. Using the control software makes the following controller operations easy: z Parameter setting z Operation setting (Step movement and raster scan) z St...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 42 ・ Press the Close button. This completes installation.
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 45 3.5. Control Screen This section explains the buttons and other items on the control screen. ① Connection display The status of RS-232 connection to the controller is displayed. Connected: CONNECT (green) Not connected: DISCONN...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 47 4. Operating Procedure This chapter explains how to use the system. Operations by [Control Software] and by [RS-232C command] are explained together. 4.1. Controller Start Up When the power (+5 V, +24 V) is turned on, the contr...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 49 4.2. Step Movement Execute step movement for a fixed angle. Control Software ・ Select the Step Move tab. ① ・ Select an axis for step movement. ② ・ Specify the displacement (angle or pulse count) for relative position (STEP) and...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 57 • The step response waveform displays (blue). (The above display is the measurement results for 0.12 deg (Mechanical) step movement.) • Press the REF button. ② • The response waveform (gray) saved in reference data is overwritt...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 59 4.3. Raster Scan Execute oscillation of a fixed angle at a fixed frequency. Control Software ・ Select the Raster Scan tab. ① ・ Select an axis for raster scan. ② ・ Specify the operation parameters (Scan Time, Scan Angle, Duty, a...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 61 4.4. Position Command Input by High-speed Serial Communication In order to carry out a vector scan, target position data is given to the controller by high-speed serial communication, and the data is updated as required. It is ...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 62 5. Monitor Output and Digital Input Functions The controller has an analog monitor output connector for monitoring the operation status and a digital I/O connector for external signal input. 5.1. Connector Pin Assignment The co...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 63 Evaluation Monitor Board Pin Assignment Pin Assignment of the optional monitor board for evaluation is as follows. A1 A2 A3 A4 A5 A6 A7 A8 D1 D2 D4 D5 D9 D10 D15 D16 D3 D6 D11 D12 D1 D18 GND GND Digital I/O Analog Monitor
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 64 Analog monitor output connector Connector model number Connector Model No. Manufacturer Board side XG4C-1034 OMRON Cable side XG4M-1030-T OMRON Connector pin assignment Pin No. Monitor Board for Evaluation Signal Name Signal De...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 65 Digital I/O connectors Connector model number Connector Model No. Manufacturer Board side 8931E-020-178L KEL Cable side 8925E-020-179 KEL Connector pin assignment Pin No. Monitor board for evaluation Signal Name I/O Signal Desc...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 70 6. Other - Operation Setting 6.1. Setting Controller Start Up Mode Clock selection With the default settings at shipping, a parameter is set to start up the controller in RS-232C communication command input mode (internal clock...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 75 Input the external trigger signal The external trigger signal is input from the digital I/O connector. (See 5-1 ‘Connector Pin Arrangement) Connector pin arrangement Pin No. Monitor Board Signal Name I/O Signal Description Logi...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 76 7. Tuning 7.1. Tuning At the time of shipping, with the combination of the galvano motor and controller (GC-201), appropriate servo tuning has been completed. The following tools have been prepared to check malfunctions during ...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 79 • The frequency characteristic measurement results display. • By dragging the cursor (point where red lines intersect), specified frequency detailed information (measured frequency points, gain, and phase) will display ② • Pres...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 95 8. Commands The controller has a monitor output (analog output) terminal for monitoring the RS-232C command operation status and an external signal input terminal for controller operation. 8.1. List of Commands ID Command Name ...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 101 Command ID 15 Command Name Error Read Data - Return Value Error (16 bits) Explanation Each status can be checked by each bit after conversion into 16-bit display. For details about errors, see 9.2, “Errors.” Bit Abbreviation M...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 108 9. Parameters 9.1. List of Parameters ID Parameter Name 0 CW Limit 1 CCW Limit 2 Max Velocity 3 In-position Range 4 Settling Check Time 5 In-position Overtime 6 LQ Control Gain 7 Torque Constant 8 Total Inertia 9 Motor Current...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 125 Parameter ID 68 Parameter Name High Speed Serial Data LSB Position Data High Speed Serial Data LSB Position (Unit: bit) Range = 0 ~ 4 Return Value 0: Parameter setting successful 1: Parameter setting unsuccessful Explanation T...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 126 9.3. Modifying Parameters This section explains how to modify parameters. Control Software ・ Select the All Parameter tab. ① ・ Select an axis for parameter settings. ② ・ The current parameter values are displayed. ③ ・ Modify t...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 129 10. Safety Functions This system has various safety functions to ensure safe use. 10.1. Safety Functions The safety functions can be classified into hardware monitoring and software monitoring. Hardware monitoring ・ Power supp...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 130 10.2. Errors Priority: High Error Hex Monitor Item Error Condition Setting Change Possible /Impossible (Parameter) System status after error Digital Output Recovery Method Stroke over 0x0001 Encoder pulse count The encoder cou...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 132 11. Appendix 11.1. Firmware Update The GC-201 controller is equipped with two DSP’s (Digital Signal Processor) for Axis 1 and for Axis 2, and the same firmware is written in each DSP. When firmware is upgraded for the addition...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 133 11.1.1. Writing Procedure Carry out operations according to the following procedure. It will be necessary to operate DIP switches and jumper switches on the controller. Please follow this procedure. 1. Preparation - Turn off p...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 137 11.2. Parameter Changes from the Number of Encoder Divisions As explained in 2.8.1 Number of Encoder Pulses, the scanner motor encoder signal is divided into 8,192 divisions generating encoder pulses within the GC-201 controll...
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 139 NOTE
CANON Digital Galvano Scanner System GM-1000 Series Users Manual 1.20 140 Canon Inc. Canon Marketing Japan Inc. 2-16-2, Konan, Minato-ku, Tokyo 108-8011 CB Sales Department Tel. 03-3740-3336 ・ The contents of this document are subject to change without notice. ・ If you find any question, error, or o...
Canon Manuals
-
Canon 6130280
User Manual
-
Canon imageCLASS MF284dw
User Manual
-
Canon imageCLASS MF289dw
User Manual
-
Canon imageCLASS LBP172dw
User Manual
-
Canon 248
User Manual
-
Canon 323
User Manual
-
Canon 323
Installation Manual
-
Canon 323
Manual
-
Canon 250
User Manual
-
Canon 251
User Manual
-
Canon 251
Manual
-
Canon 251
Troubleshooting Guide
-
Canon 6710C002
User Manual
-
Canon K10605
User Manual
-
Canon K10613
User Manual
-
Canon K10608
User Manual
-
Canon K10609
User Manual
-
Canon imageRUNNER C3326i
User Manual
-
Canon imageCLASS MF465dw
User Manual
-
Canon K10617
User Manual