Canon G 2000- Manuals
Canon G 2000– User Manual, Manual in PDF format online.
Manuals:
User Manual Canon G 2000
Summary
CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA 1 CHAPTER 1 INTRODUCTION Overview Scope of the manual This manual is intended to provide information on the installation,characteristics and operat...
3 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA Safety features Overheat thermistor A thermistor in the bath senses any over-temperature fault condition. Ifsuch a condition occurs, all power is...
CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA 5 CHAPTER 2 UNPACKING AND ASSEMBLY This chapter of the manual provides assistance in unpacking and assem-bling the CT-2000 Constant Temperature Bat...
6 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA Assembly procedure 1. Unpack the bath unit housing and move it to its permanentlocation on a stable labora-tory bench or table. 2. Remove all eig...
9 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA PREHEAT cable to PREHEAT socket CONTROL HEATER cable to CONTROL HEATER socket FAN cable to FAN socket MOTOR STIRRER cable to MOTOR socket...
10 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA Thermometer immersion Proper thermometer immersion is critical for viscosity measurements.Even a calibrated thermometer will read incorrectly if...
11 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA Draining the Bath If it becomes necessary to drain the liquid from the bath: Obtain a suitable container to hold all of the liquid drained from ...
CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA 13 CHAPTER BATH OPERATION NOTE Different thermometers have different installation requirements. Refer tothe information included with the thermomet...
14 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA TEMPERATURE Actual Target 20.003 C 100.000 C HEATING To Cold Start the CT-2000, toggle the power BATH switch up. The POWER lamp should light whe...
16 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA If the self-test sequence is accomplished successfully, the CT-2000 willcommence normal operations. If any component of the self-test fails, the...
17 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA The front panel of the CT-2000 provides a Liquid Crystal Display (LCD)screen and a simple keypad interface (see Figure 12 ). 1 2 ) . Figure 12: ...
18 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA MENU allows user to change temperature scale (°F-°C), reset calibration offsets and change other system settings (See Menu options ). Setting ...
20 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA MENU options The MENU selection from the CT-2000 keypad permits the user to access three functions: Change to (C/F) Changes screen display to ...
21 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA General Bath Offset The General Bath Offset is a protected function of the CT-2000. Thisoption is a global adjustment which is made at the facto...
CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA 29 CHAPTER A APPENDIX A — MODEL CT- 2000 PROBLEM ANALYSIS A successful CT-2000 self-test is an indicator that there are no detectableerrors and che...
CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA 31 CHAPTER B APPENDIX B — CORRECTING SHAFT & IMPELLER MISALIGNMENT Motor-stirrer units supplied by CANNON ® Instrument Company are checked afte...
CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA 33 CHAPTER C APPENDIX C — CHOOSING A TEMPERATURE BATH LIQUID The ideal bath liquid would possess low viscosity, high heat capacity, andlow vapor pr...
CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA 35 CHAPTER D APPENDIX D — CT-2000 SPARE PARTS LIST Following is a list of parts for the CT-2000 which may be ordered from CANNON ® Instrument Compa...
CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA 37 CHAPTER E APPENDIX E — WARRANTY/ RETURN INFORMATION Products limited warranty In addition to other manufacturers’ warrantees, CANNON ® Instrumen...
38 CANNON ® CT-2000 Constant Temperature Bath Revision 1.0g—February, 2012; CANNON ® Instrument Company 2139 High Tech Road • State College, PA 16803 • USA Returning a product to CANNON ® Procedure Before returning a CANNON ® product for repair or service, make every attempt to identify the problem....
Manual Canon G 2000
Canon Manuals
-
Canon 6130280
User Manual
-
Canon imageCLASS MF284dw
User Manual
-
Canon imageCLASS MF289dw
User Manual
-
Canon imageCLASS LBP172dw
User Manual
-
Canon 248
User Manual
-
Canon 323
User Manual
-
Canon 323
Installation Manual
-
Canon 323
Manual
-
Canon 250
User Manual
-
Canon 251
User Manual
-
Canon 251
Manual
-
Canon 251
Troubleshooting Guide
-
Canon 6710C002
User Manual
-
Canon K10605
User Manual
-
Canon K10613
User Manual
-
Canon K10608
User Manual
-
Canon K10609
User Manual
-
Canon imageRUNNER C3326i
User Manual
-
Canon imageCLASS MF465dw
User Manual
-
Canon K10617
User Manual