Page 2 - Installation and Operation; Page 2; Table of Contents
Avaya Inc. Installation and Operation Model EA401 Page 2 Table of Contents Package Contents .............................................................................................2 Overview ...........................................................................................................
Page 3 - Page 3; Overview
Avaya Inc. Installation and Operation Model EA401 Page 3 Overview Model EA401 Explosive Atmosphere Telephone This Explosive Atmosphere telephone provides safe and reliable communication in hazardous locations, up to and including Class I Division 1. Only standard wiring and fittings are required to ...
Page 4 - Page 4
Avaya Inc. Installation and Operation Model EA401 Page 4 Figure 1 - Features Figure 2 - Dimensions WARNING FIELD REPAIR NOT POSSIBLE. FOR SERVICE RETURN TO FACTORY. TO PREVENT IGNITION OF HAZARDOUS ATMOSPHERE, DISCONNECT FROM THE SUPPLY CIRCUIT BEFORE OPENING OR REPLACING FUSE. KEEP TIGHTLY CLOSED W...
Page 5 - Page 5; Warnings; acetylene may be present in the atmosphere.; General Requirements
Avaya Inc. Installation and Operation Model EA401 Page 5 Warnings • In no case should this telephone apparatus or wiring be installed in a location where acetylene may be present in the atmosphere. • Two back cover retaining bolts on the model EA401 are factory sealed. Damage to the seals voids the ...
Page 6 - Page 6; Installing the EA401
Avaya Inc. Installation and Operation Model EA401 Page 6 Installing the EA401 • Declassify the hazardous location before proceeding with any installation or electrical wiring. Caution: Installation or electrical wiring in a hazardous location could result in serious injury to personnel or damage to ...
Page 7 - Page 7
Avaya Inc. Installation and Operation Model EA401 Page 7 Figure 3 - Typical Installation 18.0" [457mm] MAX. TIP/RING/GND FROM CO OR PBX UNION FITTING EXPLOSION PROOF FITTING SEALING ATMOSPHERE TELEPHONE EA401: EXPLOSIVE HEIGHT: 1.4m (4.6') SUGGESTED MOUNTING WARNING FIELD REPAIR NOT PO SSIBLE. F...
Page 8 - After mounting the telephone follow these steps.; not; be connected to the local exchange until; Figure 4 - Lower Junction Box Wiring
Avaya Inc. Installation and Operation Model EA401 Page 8 Wiring For Tip & Ring • After mounting the telephone follow these steps. • Run tip, ring and ground wires from the local exchange into the lower junction box. The tip and ring wires must not be connected to the local exchange until install...
Page 9 - Page 9; Fuse Replacement; central office before attempting to replace the fuse.; NOTES; Figure 5 - Fuse Replacement
Avaya Inc. Installation and Operation Model EA401 Page 9 Fuse Replacement • Disconnect the telephone from tip and ring power supplied by the PABX or central office before attempting to replace the fuse. See: Figure 5 - Fuse Replacement • Remove the 1/2” NPT close up plug (item A) with a 1/4” Allen k...
Page 10 - MUST; Figure 6 - Handset Replacement; HANDSET PLUG
Avaya Inc. Installation and Operation Model EA401 Page 10 Replacement Of EA10H Telephone Handset Assembly Note: The handset cord is a 3.0 m (10 ft) long coiled cable designed specifically for use with the EA401 telephone. If damaged, the assembly may be replaced in the field. Only an EA10H handset a...
Page 11 - Remove handset from cradle.
Avaya Inc. Installation and Operation Model EA401 Page 11 Operating Instructions • Remove handset from cradle. See: Figure 1 - Features • Listen for a dial tone and then dial the appropriate digits for the feature desired. • Upon completing a call hang up by returning the handset to the cradle. • Ca...
Page 12 - Engineering Specifications; Electrical Performance
Avaya Inc. Installation and Operation Model EA401 Page 12 Engineering Specifications Electrical Performance A UDIBLE R ANGE F REQUENCY R ESPONSE 300 – 3400 H Z D IALING M ETHOD IEEE DTMF OR 40/60 P ULSE , 10 PPS T RANSMIT O BJECTIVE L OUDNESS R ATING (TOLR) -38 +/- 4 dB R ECEIVE O BJECTIVE L OUDNESS...
Page 13 - NPT; Compliances; III; LISTED
Avaya Inc. Installation and Operation Model EA401 Page 13 R ECEIVER H EARING A ID C OMPATIBLE D IAL P AD O VERSIZED A LUMINUM B UTTONS ON 1.125” G RID S TANDARD M OUNTING V ERTICAL W ALL C ONNECTION F ITTINGS ½” NPT C ONDUIT E NTRY Compliances I NDUSTRY C ANADA 1012 4339 A FCC HQHCAN-65560-TE-E CSA ...
Page 14 - Government Certification; Industry Canada
Avaya Inc. Installation and Operation Model EA401 Page 14 Government Certification Attached to the telephone are labels for Industry Canada and the United States Federal Communications Commission. These identify equipment certifications indicating the 60 and 70 series telephones meet certain telecom...
Page 15 - or if; Disclaimer; Avaya’s Model EA401 Explosive Atmosphere telephone must; NOT; be opened by the user, doing so; voids; Service Telephone Number; please call the toll-free telephone number
Avaya Inc. Installation and Operation Model EA401 Page 15 Warranty Avaya warrants your product to be free of defects in material and workmanship for a period of one year. Avaya will repair or replace any defective unit that is under warranty free of charge. This warranty is null and void if any non-...
Page 16 - Avaya Product Return; Step III - Factory Authorized Service
Avaya Inc. Installation and Operation Model EA401 Page 16 Avaya Product Return Avaya products have been quality tested and are in full working order when shipped from the factory, given the rugged nature of these products, shipping is not expected to damage a unit. In the unlikely event of a malfunc...
Page 18 - APPENDIX A; APPENDIX B - Applications
Avaya Inc. Installation and Operation Model EA401 Page 18 APPENDIX A (cont.) CLASS II, DIVISION 1 & 2, GROUP E Atmospheres containing combustible metal dusts regardless of resistivity, or other combustible dusts of similarly hazardous characteristics having resistivity of less than 105 ohm-centi...
Page 19 - Model
Avaya Inc. Installation and Operation Model EA401 Page 19 Notes: Model No. Part No. Serial No. Date of Purchase