Summary
Issue 3 January 2008 3 Chapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 How to use this documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Downloading this boo...
Contents 4 Installing and Connecting the MDF and Telephones Site locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Station circuit distribution from equipment room . . . . . . . . . . . . . . . . . 44 4-pair station circuits . . . . . . . . . . . . . . . . . . . . ....
Contents Issue 3 January 2008 5 Dual wiring of 2-wire and 4-wire endpoints . . . . . . . . . . . . . . . . . . . 87 Installing the attendant console . . . . . . . . . . . . . . . . . . . . . . . . . 87 Installing the 26B1 Selector Console . . . . . . . . . . . . . . . . . . . . . . 88 Connecting ext...
Contents 6 Installing and Connecting the MDF and Telephones Connecting cables to telephones and other end devices . . . . . . . . . . 122 1152B Mid-Span Power Distribution Units . . . . . . . . . . . . . . . . . . . . . . 123 Important 1152B PDU Safety Instructions . . . . . . . . . . . . . . . . . ...
Contents Issue 3 January 2008 7 LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Telephone console LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 Attendant console LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . 148Terminal a...
Issue 3 January 2008 9 Chapter 1: Introduction This documentation, Installing and Connecting the MDF and Telephones provides procedures for installing Main Distribution Frames (MDF) and telephones. The procedures explain how you connect media gateways to the MDF and how to connect the MDF to the pub...
Introduction 10 Installing and Connecting the MDF and Telephones Connect the necessary telephone, trunking, and peripheral equipment using the information in Installing and wiring telephones and trunks on page 69 and Installing and wiring telephone power supplies on page 109. Complete the installati...
Related resources Issue 3 January 2008 11 Sending us comments Avaya welcomes your comments about this book. To reach us by: ● Mail, send your comments to: Avaya Inc.Product Documentation GroupRoom B3-H131300 W. 120th Ave.Westminster, CO 80234 USA ● E-mail, send your comments to: [email protected] ●...
Introduction 12 Installing and Connecting the MDF and Telephones ● Maintenance Commands for Avaya Communication Manager 5.0, Media Gateways and Servers, (03-300431). Provides information on how to use command interfaces, command syntax, and output from maintenance-related commands. ● Maintenance Ala...
Issue 3 January 2008 13 Chapter 2: Installing the main distribution frame If the equipment room does not have one, you must build a main distribution frame (MDF) that connects the media gateways to the building phone network and to the public switched telephone network (PSTN). The tasks include the ...
Installing the main distribution frame 14 Installing and Connecting the MDF and Telephones Cable Slack Manager A Cable Slack Manager is 32 inches (81.3 centimeters) wide. Slack managers are commonly used in installations consisting of media gateway stacks, such as the SCC1 Media Gateways. Determine ...
Physical requirements and layout Issue 3 January 2008 15 Sizing 4-pair station cables Use the scale of the floor plan to determine the approximate length of the station cables required per the standard SYSTIMAX wiring concepts. Sizing 25-pair and multiple 25-pair station cables Use the scale of the ...
Installing the main distribution frame 16 Installing and Connecting the MDF and Telephones Main distribution frame cross-connect fields Each main distribution frame (MDF) contains a trunk/auxiliary field and a distribution field. The trunk/auxiliary field contains three cross-connect areas: ● The gr...
Main distribution frame hardware installation Issue 3 January 2008 17 Main distribution frame hardware installation This section provides information on installing a main distribution frame (MDF) in an equipment room. It must be installed before connecting media gateways to it and before connecting ...
Main distribution frame placement Issue 3 January 2008 19 Main distribution frame placement The preferred location of the MDF is directly behind the media gateways. Figure 3: Typical 110A-type terminal blocks (G650 Media Gateway) shows a typical installation using 110A-type terminal blocks. Figure 3...
Installing the main distribution frame 20 Installing and Connecting the MDF and Telephones Main distribution frame labels Figure 4: Label graphic symbols and nomenclature on page 20 shows the graphic symbols used on labels for the media gateways, cross-connections, information outlets, and cables. T...
Mounting 110A- or 110P-type terminal blocks on the wall Issue 3 January 2008 21 Mounting 110A- or 110P-type terminal blocks on the wall The 110A-type terminal blocks can be stacked in almost any arrangement at any height or location on the wall. Figure 5: 110A-type terminal blocks (300-pair) on page...
Installing the main distribution frame 22 Installing and Connecting the MDF and Telephones 11. If installing another distribution field terminal block, partially install the first screw for the terminal block, on the line, 7/8-inch (2.2 centimeter) to the right of the previous screw. Partially insta...
Installing the main distribution frame 24 Installing and Connecting the MDF and Telephones Mounting 110P-type terminal blocks on a frame The 900-pair 110P-type terminal blocks and the associated patch cord troughs can also be mounted on a free-standing, floor-mounted 1110A2 Apparatus Mounting Frame....
Installing Cable Slack Managers Issue 3 January 2008 25 Installing Cable Slack Managers Run excess cables on an upper cable ladder (if the MDF connectors are on top) or route them through a cable slack manager that is placed next to the MDF. To install cable slack managers: 1. Place the Z113A Cable ...
Installing the main distribution frame 26 Installing and Connecting the MDF and Telephones Cable clamps are required in installations with cable slack managers. At the rear of the media gateways, install two cable clamps using the screws provided. These clamps hold the 25-pair input/output or MDF ca...
Issue 3 January 2008 29 Chapter 3: Installing the patch panel Installing patch panels This chapter is for installations using a patch panel rather than a main distribution frame for connections to the building phone network and the public switched telephone network (PSTN). Patch panels are arrays of...
Installing the patch panel 30 Installing and Connecting the MDF and Telephones Figure 10: Typical RMC patch panel installation Figure notes: 1. Circuit pack amphenol connectors and B25A cables 2. IP server interface adapter and green CAT5 cable 3. 24-port patch panels4. 8-port patch panel5. To netwo...
Cross-connecting the media gateway to the patch panels Issue 3 January 2008 31 Figure 11: Sample cross-connect field patch panel connections widfccf2 EWS 102798 4 11 0 1 9 41 3 2 2 21 1 2 0 51 4 2 3 31 2 2 1 61 5 2 4 91 8 71 6 2 5 81 7 Port T ie T runk Port MET Line 4 4 Port T ie T runk w/ E&M S...
Issue 3 January 2008 33 Chapter 4: Media gateway connections to the MDF Once the main distribution frame (MDF) is installed and wired, you must connect the media gateways to the MDF. Run excess cables on an upper cable ladder (if the MDF connectors are on top) or route them through a cable slack man...
Media gateway connections to the MDF 34 Installing and Connecting the MDF and Telephones Figure 12: Equipment room cabling labels The top blue/yellow building and floor labels are for cables connecting from the equipment room to a site/satellite location on another floor or in another building. The ...
Equipment room cabling labels Issue 3 January 2008 35 Figure 12: Equipment room cabling labels on page 34 details the label name and range of each label. Table 3: Cable/connector/building label ordering information provides label ordering information. Figure 13: Self-stick label on 25-pair cable con...
Media gateway connections to the MDF 36 Installing and Connecting the MDF and Telephones Cable routing guidelines Figure 14: Cable routing to top terminal blocks and Figure 15: Cable routing to bottom terminal blocks on page 37 show typical cable routing from the media gateway to the top and bottom ...
Cable routing guidelines Issue 3 January 2008 37 Figure 15: Cable routing to bottom terminal blocks Use these guidelines when routing cables from the media gateway to the MDF. Following these guidelines will maximize use of the cable slack managers and make future cabling additions and changes easie...
Media gateway connections to the MDF 38 Installing and Connecting the MDF and Telephones ● Coil the cable around the columns in the cable slack manager to store cable slack. The first run should always go across the full length of the 5 columns in the cable slack manager. ● Connect the cable to the ...
Installing connector cables between auxiliary cabinet and MDF Issue 3 January 2008 39 Installing connector cables between auxiliary cabinet and MDF Auxiliary equipment that connects to the MDF can be mounted inside the auxiliary cabinet. The equipment connects to an ED-1E1443-10 (Group 1) intraconne...
Issue 3 January 2008 41 Chapter 5: MDF connections to stations and the public switched telephone network Once the main distribution frame (MDF) is completed and the media gateways are connected to the MDF, you must connect the MDF to stations (telephones) and the public switched telephone network (P...
MDF connections to stations and the public switched telephone network 42 Installing and Connecting the MDF and Telephones Station cables For clarity a station cable is either a 25-pair cable, multiple 25-pair cable, or 4-pair D-inside wire (DIW) run from the equipment room, site/satellite location, ...
Closets Issue 3 January 2008 43 4-pair station cable — Use this cable when 4-pair station cables are to be field-terminated on the 110-type terminal blocks in the equipment room or satellite closet and the information outlets require push-on connections. Figure 17: Example of extending 4-pair statio...
MDF connections to stations and the public switched telephone network 44 Installing and Connecting the MDF and Telephones Satellite locations using 110-type hardware Each terminal block has a 3-pair (white field) and a 4-pair (blue field) located on the same terminal block. The 110A-type terminal bl...
Station circuit distribution from equipment room Issue 3 January 2008 45 If most of the telephones/voice terminals that require remote powering are within 250 feet (76.2 meters) of the equipment room, 4-pair station circuits are run from the equipment room to the information outlets. If this is not ...
MDF connections to stations and the public switched telephone network 46 Installing and Connecting the MDF and Telephones Figure 18: 4-pair circuit distribution and connectivity Figure notes: 1. Part of Main Distribution Frame (MDF) 2. 3-Pair Connecting Blocks3. 4-Pair Connecting Blocks4. Purple Fie...
Station circuit distribution from equipment room Issue 3 January 2008 49 Figure 22: 3-pair to 4-pair circuit distribution and connectivity Figure notes: 1. Part of Main Distribution Frame (MDF)2. 3-Pair Connecting Blocks3. Purple Field4. Blue Field5. Patch Cord or Cross-Connect Jumpers6. To Media Ga...
MDF connections to stations and the public switched telephone network 50 Installing and Connecting the MDF and Telephones Connected cable station adapters Station adapters are used to provide modular connectivity either directly to a telephone or to an information outlet. See Figure 23: 258A and BR2...
Connected cable station adapters Issue 3 January 2008 51 Figure 24: 356A Adapter Figure notes: 1. 356A Adapter 2. 4-Pair Modular Jacks (6 pins each, connected to 25-pair ribbon connector) Table 4: Adapter ordering information Description Comcode 258A Adapter 102605136 BR2580A Adapter 403384720 356A ...
MDF connections to stations and the public switched telephone network 52 Installing and Connecting the MDF and Telephones Completing a provisioning plan A provisioning plan should be completed before an installation. The plan determines an appropriate available port circuit on the media gateway for ...
MDF connections to stations and the public switched telephone network 54 Installing and Connecting the MDF and Telephones Installing sneak current and off premise protection Protection from hazardous voltages and currents is required for all off-premises (out of building) trunks, lines, and terminal...
Installing sneak current and off premise protection Issue 3 January 2008 55 Figure 26: Model 507B sneak fuse panel Connector cables (B25A male to female) connect the network interface to the sneak fuse panel. Also, 157B connecting blocks equipped with SCP-110 protectors can be used for sneak current...
MDF connections to stations and the public switched telephone network 56 Installing and Connecting the MDF and Telephones The 507B includes 52 sneak fuses and two cables and can be ordered using PEC code 63210. Use the SCP-110 protectors with 110-type hardware and on the 507B sneak fuse panel. The S...
Installing sneak current and off premise protection Issue 3 January 2008 57 Installing sneak fuse panels For general information, see Installing sneak current and off premise protection on page 54. Figure 26: Model 507B sneak fuse panel on page 55, or equivalent, is recommended for sneak current pro...
MDF connections to stations and the public switched telephone network 58 Installing and Connecting the MDF and Telephones Installing the coupled bonding conductor The coupled bonding conductor (CBC) provides a path to ground for transient energy (for instance, lightning) by virtue of mutual inductan...
MDF connections to stations and the public switched telephone network 60 Installing and Connecting the MDF and Telephones To provide the coupled bonding protection: 1. Cut a 10 AWG (#25) (2.5 mm 2 ) wire long enough to reach from the equipment room single-point ground block (or DC power Ground Disch...
Installing the coupled bonding conductor Issue 3 January 2008 61 Figure 28: Coupled Bonding Conductor Figure notes: 1. 25-Pair Tip & Ring Cables to Media Gateways 2. Coupled Bonding Conductor (CBC) Terminal Block 3. Tie Wraps4. Cable Shield or Six Spare Pairs5. Ground on Carbon Block Protector o...
MDF connections to stations and the public switched telephone network 62 Installing and Connecting the MDF and Telephones Installing and administering the patch cord/jumper Before starting the patch cord installation, obtain a copy of the Port Assignment Record forms from the customer or marketing r...
Installing and administering the patch cord/jumper Issue 3 January 2008 63 Figure 29: Example 3-pair labeling to information outlet Figure notes: 1. Equipment Room2. Satellite Location3. Work Location4. White Row on 110 Terminal Block5. Purple Row on 110 Terminal Block6. Blue Row on 110 Terminal Blo...
MDF connections to stations and the public switched telephone network 64 Installing and Connecting the MDF and Telephones Figure 30: Example 4-pair labeling to information outlet Labeling expansion control carrier cable(MCC1 Media Gateway only) To label the expansion control carrier cable: 1. Place ...
Installing and administering the patch cord/jumper Issue 3 January 2008 65 Connecting expansion control carrier outputs cable (MCC1 Media Gateway only) To connect the expansion control carrier outputs cable: 1. Plug the connector cable in the AUX connector on the rear of the expansion control carrie...
Installing and administering the patch cord/jumper Issue 3 January 2008 67 Connecting trunk pairs to media gatewayusing jumper wires to establish 3-pair modularity Figure 32: 3-pair modularity for trunk pairs for 1-pair trunks on page 67 and Figure 33: 3-pair modularity for trunk pairs for 3-pair Ti...
Issue 3 January 2008 69 Chapter 6: Installing and wiring telephones and trunks The wiring procedures are the same for most Avaya telephones and other equipment.This task list provides wiring examples of similar installation procedures. These are examples only; actual wiring procedures may vary at ea...
Installing and wiring telephones and trunks 70 Installing and Connecting the MDF and Telephones ● Connecting external alarm indicators and auxiliary power on page 88 ● Installing off-premises station wiring on page 90 ● Off-premises or out-of-building stations on page 91 ● Off-premises connections o...
Connecting telephones Issue 3 January 2008 73 Connecting a typical telephone The 302D Enhanced Attendant Console is used to describe a telephone connection typically used with the 84xx (4-wire) telephones.The 302D does not require auxiliary power unless it has a 26C1 DXS console or Vacuum Fluorescen...
Installing and wiring telephones and trunks 74 Installing and Connecting the MDF and Telephones Figure 34: 302D to 4-wire DCP wiring Connecting adjunct power The 400B2 adapter is convenient for connecting local -48 VDC power to a modular plug. See Figure 35: 400B2 Adapter connecting to a modular plu...
Connecting telephones Issue 3 January 2008 75 Figure 35: 400B2 Adapter connecting to a modular plug Connecting an analog station or 2-wire digital station This example is typical of the 2-wire digital stations (2420, 64xx, 302D), 2-wire analog stations (2500), analog central office (CO) trunks, dire...
Installing and wiring telephones and trunks 76 Installing and Connecting the MDF and Telephones Figure 36: 2500-type analog telephone wiring Analog tie trunk example This example shows how to connect analog tie trunk wiring from one IP Connect or Multi-Connect configuration to another one or any oth...
Connecting telephones Issue 3 January 2008 77 4. Figure 37: Analog Tie Trunk wiring on page 77 shows a media gateway tie trunk connected to another media gateway tie trunk. Names of the tie trunk leads must be determined from the manufacturer or supplier of the external trunk circuit. 5. Administer ...
Installing and wiring telephones and trunks 78 Installing and Connecting the MDF and Telephones Figure 38: Digital Tie Trunk wiring DS1 tie trunk example Digital Signal Level 1 (DS1) tie trunks provide a 1.544 Mbps (T1) or 2.048 Mbps (E1) digital data service between two collocated configurations or...
Connecting telephones Issue 3 January 2008 79 DS1 interface trunks using T1 channel service unit The T1 channel service unit (CSU) interfaces the DS1 interface trunks with the 1.544 megabits per second digital facility.Connect the DS1 interface trunk to a T1 CSU. See Figure 39: Typical connections t...
Installing and wiring telephones and trunks 80 Installing and Connecting the MDF and Telephones Table 9: DS1 cables Connector cable Description and usage C6C connector cable 50-feet (15 meters) shielded cable equipped with a 50-pin male connector on one end and a 15-pin male connector on the other e...
Auxiliary connector outputs (MCC1 and SCC1 Media Gateways only) Issue 3 January 2008 81 Auxiliary connector outputs (MCC1 and SCC1Media Gateways only) Connect a 25-pair cable from the AUX connector on the back of the expansion control carrier to a connecting block on the trunk/auxiliary field. Table...
Installing and wiring telephones and trunks 82 Installing and Connecting the MDF and Telephones R-O O-R 32 7 GRD R-G G-R 33 8 Not Connected R-BR BR-R 34 9 Not Connected R-S S-R 35 10 Not Connected BK-BL BL-BK 36 11 -48 GND Emergency Transfer Relay Power BK-O O-BK 37 12 -48 GND BK-G G-BK 38 13 -48 GN...
Auxiliary connector outputs (MCC1 and SCC1 Media Gateways only) Issue 3 January 2008 83 Table 12: Station pinout chart provides the station printout chart. V-BR BR-V 49 24 Not Connected V-S S-V 50 25 INADS Tip INADS Ring *. Color designation is the main wire color and the color of the stripe on the ...
Installing and wiring telephones and trunks 84 Installing and Connecting the MDF and Telephones Three-pair and four-pair modularity Figure 40: 3-pair and 4-pair modularity on page 84 is from the port circuit pack to the voice or data terminal.Most terminals connect to an information outlet (modular ...
Adjunct power connection locations Issue 3 January 2008 85 Adjunct power connection locations Figure 41: Example adjunct power connections on page 85 shows typical connection locations for adjunct power. Adjunct power for station equipment may be supplied from the equipment room, satellite location,...
Installing and wiring telephones and trunks 86 Installing and Connecting the MDF and Telephones Attendant console example Perform these tasks to install an attendant console ● Installing the attendant console on page 87 ● Installing the 26B1 Selector Console on page 88 Attendant console cabling dist...
Attendant console example Issue 3 January 2008 87 An attendant console can also derive auxiliary power from: ● Individual 1151B1 or 1151B2 power supply ● 258A-type adapters ● Bulk power supplies such as the 1145B2 A console’s maximum distance from its auxiliary power source is: ● 800 feet (244 meter...
Installing and wiring telephones and trunks 88 Installing and Connecting the MDF and Telephones Installing the 26B1 Selector Console To install the 26B1 Selector Console: 1. Connect the supplied 3-foot (1 meter) D8AC cable to the modular jack on the bottom of the 26B1 Selector Console. 2. Route the ...
Connecting external alarm indicators and auxiliary power Issue 3 January 2008 89 Figure 43: Sample Issue 1 IPSI-2 alarm cable connectivity To connect the external alarm indicators and the auxiliary power: 1. Connect 1 major (Brown-White and White-Brown) and 1 minor (Orange-White and White-Orange) al...
Installing and wiring telephones and trunks 90 Installing and Connecting the MDF and Telephones 4. Connect emergency transfer power (Blue-White and White-Blue)) as shown in Table 14: Alarm Inputs at TN2312BP Adapter DB9 Alarm Connector . Installing off-premises station wiring The local telephone com...
Off-premises or out-of-building stations Issue 3 January 2008 91 3. Connect an A25D cable between the sneak fuse panel and the terminal block connector associated with the green row in the previous step. 4. Install a green label on the terminal block to identify the remote location. 5. Administer pe...
Off-premises connections Issue 3 January 2008 93 Figure 45: Connections to 24 out-of-building telephones Off-premises protection requirements Both building entrances require carbon block or equivalent protection and sneak current protection. Protection can be provided by: ● a 4-type protector, which...
Installing and wiring telephones and trunks 94 Installing and Connecting the MDF and Telephones The 4-type protector is the preferred device. For installations not using primary protection, 4-type protectors should always be used. When the 3-type protector is already installed, a separate sneak curr...
Off-premises connections Issue 3 January 2008 95 The 4C3S-75 may be used only with TN754B Digital Line circuit packs. Table 16: Digital Voice Circuit Protectors lists the approved protectors. When possible, all new and reused wiring installations should use blocks that accept the standard 5-pin plug...
Installing and wiring telephones and trunks 96 Installing and Connecting the MDF and Telephones See Figure 41: Example adjunct power connections on page 85 and Figure 46: Connections at trunk/auxiliary field on page 96. Figure 46: Connections at trunk/auxiliary field Emergency transfer units and ass...
808A Emergency Transfer Panel and telephone installation examples Issue 3 January 2008 97 Should power be restored to the relays while a call connected through the 808A is in progress, the 808A maintains the connection until the user goes on-hook. Each 808A can handle up to five CO trunks. 808A Emer...
808A Emergency Transfer Panel and telephone installation examples Issue 3 January 2008 99 Figure 48: 808A Emergency Transfer Panel mounting Installing the 808A Emergency Transfer Panel Note: Note: The 808A must be installed in a location that can be accessed only by authorized personnel. The locatio...
Installing and wiring telephones and trunks 100 Installing and Connecting the MDF and Telephones 4. Connect a 25-pair cable between the male RJ21 25-pair connector on the Emergency Transfer Panel and the yellow field of the MDF. Table 18: Pin assignments for 25-pair connector on page 101 shows the p...
Installing and wiring telephones and trunks 106 Installing and Connecting the MDF and Telephones Installing external ringing Connections for external ringing are at an information outlet. The media gateway side of the MDF is connected to a TN2183 (or equivalent) Analog Line circuit pack. The circuit...
Installing the queue warning indicator Issue 3 January 2008 107 Installing the queue warning indicator The connections for the queue warning indicator are the same as external ringing. An AC indicator (lamp) such as a 21C49 can be used in a uniform call distribution/direct departmental calling (UCD/...
Issue 3 January 2008 109 Chapter 7: Installing and wiring telephone power supplies This section provides information and wiring examples of installation procedures for various telephone and console power supplies. These are examples only and actual wiring procedures may vary at each site. Note: Note...
Installing and wiring telephone power supplies 110 Installing and Connecting the MDF and Telephones 4. Installing the battery mounting/wiring on page 115 5. Installing the expanded power distribution unit on page 115 6. Powering up and testing the power supply on page 116 7. Wiring the 1146B2 Power ...
1145B2 power supply Issue 3 January 2008 111 ● Power down the power unit (see label on power unit on how to do this) and refer servicing under the following conditions: ● If liquid has been spilled into any of the products ● If any of the products have been exposed to water ● If any of the products ...
Installing and wiring telephone power supplies 114 Installing and Connecting the MDF and Telephones Installing the wall-mounting plates The top plate is used for mounting the back-up battery. The bottom plate is used to mount the power supply and distribution units. The plates can be rack-mounted us...
1145B2 power supply Issue 3 January 2008 115 Installing the battery mounting/wiring Three types of back-up batteries are used. See Table 19: Back-up battery rating on page 115 for the battery type and rating. To install the battery mounting and wiring: 1. Insert two #10-32 x 1/2-inch shoulder screws...
Installing and wiring telephone power supplies 116 Installing and Connecting the MDF and Telephones See Figure 53: Expanded power distribution unit on page 113 while installing the power distribution unit. To install the expanded power distribution unit: 1. Set the spacer bracket onto the mounting p...
1145B2 power supply Issue 3 January 2008 117 2. Plug the cord into the outlet. This powers up the power supply. 3. Check AC operation of the 1145B2 Power Supply by monitoring the LEDs: PASS : Green and yellow LEDs at the front of the unit should be lit together. See Table 20: Power supply LEDs on pa...
Installing and wiring telephone power supplies 118 Installing and Connecting the MDF and Telephones Figure 54: Typical wiring to a telephone Resetting LEDs on power distribution unit A red LED next to any of the 32 power output connectors indicates a short circuit in the building wiring or the termi...
1152A1 Mid-Span Power Distribution Unit Issue 3 January 2008 119 1152A1 Mid-Span Power Distribution Unit The 1152A1 Mid-Span Power Distribution Unit (PDU) is an Ethernet power supply that provides power to up to 24 46xx-series IP telephones or wireless LAN (WLAN) access points. This unit is used wit...
Installing and wiring telephone power supplies 120 Installing and Connecting the MDF and Telephones ● Do not overload wall outlets and extension cords as this can result in the risk of line or electric shock. ● Disconnect the cords on this product and refer servicing to qualified service personnel u...
1152A1 Mid-Span Power Distribution Unit Issue 3 January 2008 121 To connect the 1152A1 Power Distribution Unit: 1. Plug a power cord into the power socket on the rear of the 1152A1 Power Distribution Unit. 2. Plug the other end of the power cord into the power receptacle. The 1152A1 PDU powers up, a...
Installing and wiring telephone power supplies 122 Installing and Connecting the MDF and Telephones Connecting cables to telephones and other end devices The 1152A1 PDU contains line-sensing capabilities that enable it to send power only to end devices designed to receive power from the LAN. These e...
1152B Mid-Span Power Distribution Units Issue 3 January 2008 123 To connect telephones and other end devices to the 1152A1 PDU: 1. Connect an Ethernet cable to the telephone using an external splitter or directly (if the device is Power over LAN Enabled). 2. Connect the opposite end of the same cabl...
Installing and wiring telephone power supplies 124 Installing and Connecting the MDF and Telephones The 1152B PDU complies with the Underwriters Laboratories Inc. (UL) standard UL 60950-1, 1 st Edition. Important 1152B PDU Safety Instructions Please read the following helpful tips. Retain these tips...
1152B Mid-Span Power Distribution Units Issue 3 January 2008 125 - Dropped or the housing has been damaged - Exhibits a distinct change in performance - Operates abnormally when following the operating instructions Using the 1152B PDUs The 1152B PDUs are used to power the 46xx series and 96xx series...
Installing and wiring telephone power supplies 126 Installing and Connecting the MDF and Telephones Figure 57: Connecting telephones and other end devices to the 1152B PDU For Data-In ports connect the Ethernet cable leading from the Ethernet Switch/Hub to the Data port. For Data & Power Out por...
1152B Mid-Span Power Distribution Units Issue 3 January 2008 127 Figure 58: Connecting an IP telephone with an external splitter Before connecting telephones or other end devices to the 1152B PDU, determine if the device: ● Is Power over LAN Enabled or not. If not, you may safely connect the telepho...
Installing and wiring telephone power supplies 128 Installing and Connecting the MDF and Telephones C360 converged stackable switches The Avaya C360 series of converged stackable switches include four main products: The C360 converged stackable switches comply with the Underwriters Laboratories Inc....
C360 converged stackable switches Issue 3 January 2008 129 ● Do not allow anything to rest on the power cord. Do not locate this product where the cord will be abused by persons walking on it. ● Do not overload wall outlets and extension cords as this can result in the risk of line or electric shock...
Installing and wiring telephone power supplies 130 Installing and Connecting the MDF and Telephones Connecting the C360 stackable switches Powering up—AC input To connect the AC input: 1. Insert the power cord into the power inlet on the rear of the unit. 2. Insert the other end of the power cord in...
1151B1 and 1151B2 Power Supplies Issue 3 January 2008 131 Connecting the cables To connect IP telephones, PCs, servers, routers, workstations, and hubs. 1. Connect the Ethernet connection cable (not supplied) to a 10/100 megabits per second port on the front panel of the Avaya C360 series switch. No...
Issue 3 January 2008 135 Chapter 8: Testing the complete configuration This section provides tests for the complete configuration, including the control and signaling networks and the telephones and consoles. This section provides tests to: ● review the status of the configuration. ● test the duplic...
Testing the complete configuration 136 Installing and Connecting the MDF and Telephones Testing port network equipment These tests verify that the time division multiplexing (TDM) cables and terminators work. If a FAIL Result code is seen, check these cables. If problems persist, see the maintenance...
Testing port network equipment Issue 3 January 2008 137 Figure 60: Sample port network status screen for Cabinet 1—Avaya S8500 Checking circuit pack configuration The list configuration report provides a list of circuit packs connected to the configuration and recognized by the software. To check ci...
Testing the complete configuration 138 Installing and Connecting the MDF and Telephones Figure 61: Sample system configuration screen — Page 4, Avaya S8700 Multi-Connect Testing the TN2312BP Internet ProtocolServer Interface circuit pack To test the TN2312BP Internet Protocol Server Interface circui...
Testing port network equipment Issue 3 January 2008 139 Figure 62: Sample IPSI 01A test results screen — Page 1, Avaya S8700 Multi-Connect Testing Expansion Interface circuit packs, if used To check each Expansion Interface (EI) circuit pack in the media gateway: 1. Type test board UUCSS where UUCSS...
Testing the complete configuration 140 Installing and Connecting the MDF and Telephones Figure 63: Sample test results for Expansion Interface Board 2A01 Testing time division multiplexing bus for each port network To check each TDM bus for each port network (PN) in the configuration. 1. Type test t...
Testing port network equipment Issue 3 January 2008 141 Testing expansion interface exchange, if used, for each port network If the configuration is critical reliability, test the expansion interface exchange for each PN: 1. Type status port-network number < 1-64 > and press Enter . This displ...
Testing the complete configuration 142 Installing and Connecting the MDF and Telephones Figure 66: Sample of port network status after expansion link is set Saving translations, if required ● Type save translations and press Enter to save the translations to the hard drive. Testing telephones and ot...
Testing telephones and other equipment Issue 3 January 2008 143 ● Testing external ringing on page 144 ● Testing queue warning indicator on page 144 ● Testing integrated announcement on page 144 ● Testing music-on-hold on page 145 ● Testing emergency transfer (Avaya S8700 Multi-Connect only) on page...
Testing the complete configuration 144 Installing and Connecting the MDF and Telephones Testing selector console To check that all selector console lamps are operational and make a call to a telephone in the configuration: 1. Simultaneously press and hold Ringer Volume up and POS BUSY on the attenda...
Testing telephones and other equipment Issue 3 January 2008 145 Record an announcement To record an announcement: 1. Select a test telephone with console permissions enabled. 2. Dial the access code followed by the integrated announcement extension number. 3. When you hear a dial tone, press 1 . Whe...
Testing the complete configuration 146 Installing and Connecting the MDF and Telephones Testing terminating trunk transmission The terminating trunk transmission test provides for extension number access to 3 tone sequences that can be used for trunk transmission testing from the distant end of the ...
LED indicators Issue 3 January 2008 147 Testing connectivity to the LAN To test the external IP connections for the C-LAN, IP Media Processor, and VAL circuit packs, you must ping the circuit pack and ping a known computer connected to your network. If everything is configured correctly, the Result ...
Testing the complete configuration 148 Installing and Connecting the MDF and Telephones Telephone console LEDs Telephones and attendant consoles have some alarm LEDs that must be checked out. Attendant console LEDs The console has two red LED s, labeled “ALM” and “ACK”. The ALM LED lights steadily w...
LED indicators Issue 3 January 2008 149 Figure 67: TN1654 DS1 Converter circuit pack LEDs The yellow LED indicates the state of the fiber interface, the fiber channel, the control channel, and the communications link to the SPE in the following manner and order of priority. See Table 23: DS1 Convert...
Testing the complete configuration 150 Installing and Connecting the MDF and Telephones SPAN LEDs The four SPAN LEDs indicate the status of the four T1/E1 facilities. A SPAN LED is in one of the following states: ● Solid on yellow: Facility is operational and alarm free. ● Blinking yellow for 2 seco...
Issue 3 January 2008 151 Index Index Numerical 110A-type terminal blocks (G650) . . . . . . . . . . 19 110P-type terminal blocks, frame-mounting . . . . . 24 110-type hardware . . . . . . . . . . . . . . . . . 17 110-type hardware, SCP-110 sneak current protection 54 110-type terminal blocks . . . ....
Avaya Manuals
-
Avaya 16-601433
Manual
-
Avaya 4600
Manual
-
Avaya 1603
Manual
-
Avaya 555-245-703
Manual
-
Avaya Gigabit Ethernet Adapter
Manual
-
Avaya 4606
Manual
-
Avaya 585-215-871
Manual
-
Avaya 4412D+
Manual
-
Avaya S8400
Manual
-
Avaya 10-Watt
Manual
-
Avaya 9600
Manual
-
Avaya R3.0
Manual
-
Avaya 1120E
Manual
-
Avaya 555-245-600
Manual
-
Avaya 16xx
Manual
-
Avaya Desk
Manual
-
Avaya B149
Manual
-
Avaya 2402
Manual
- Avaya AP-5 Manual
-
Avaya IPM515
Manual