Page 2 - System Manager/Zone Coordinator User’s Manual; TABLE OF CONTENTS; System Manager/Zone Coordinator; User’s Manual
2 System Manager/Zone Coordinator User’s Manual TABLE OF CONTENTS Document Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 6 - Document Introduction; See; Related Documentation; Table 1: System Manager/Zone Coordinator User’s Guide Related; For Information On
System Manager/Zone Coordinator User’s Manual 6 428516-YUM-B-0908 System Manager/Zone Coordinator User’s Manual Document Introduction This document describes how to operate the System Manager (YK-SMU2x0-0) and Zone Coordinator (YK-ZCU2x0-0 and YK-ZCU4x0-0) with display. These products are user inter...
Page 7 - System Manager/Zone Coordinator on the Network
System Manager/Zone Coordinator User’s Manual 7 428516-YUM-B-0908 System Manager/Zone Coordinator on the Network The System Manager and Zone Coordinator provide User Interfaces (UIs) to the devices in the YCCS network. The display units typically install in a main equipment or control room, and conn...
Page 8 - System Configuration; System Startup
System Manager/Zone Coordinator User’s Manual 8 428516-YUM-B-0908 System Configuration Components of the YCCS self configure as they come online. The system requires no database commissioning or programming – the System Manager detects all Coordina-tors on the network and displays them to the user. ...
Page 9 - System Manager/Coordinator Menu Structure; Figure 2: Local Controller Display Menu Structure
System Manager/Zone Coordinator User’s Manual 9 428516-YUM-B-0908 System Manager/Coordinator Menu Structure Figure 2 is a top level flowchart of the menu structure for the System Manager/Coordi-nator. The menu selections are described in the following sections. See the referenced figure numbers for ...
Page 10 - Screen Layout; Main Selection Bar; Table 2: Icons on Main Selection Bar; Button; Home icon - returns the display to the Home screen.; Figure 3: System Manager Basic Screen Layout
System Manager/Zone Coordinator User’s Manual 10 428516-YUM-B-0908 Screen Layout The screens that you access from the System Manager/Coordinator’s Home Screen share a common layout and theme. Each screen has a main selection bar, title area, main display area, help text/paging information area, and ...
Page 11 - Title Area; Page x of y; appears in this area.; Navigation Area
System Manager/Zone Coordinator User’s Manual 11 428516-YUM-B-0908 Title Area The title area shows the name of the display or edit screen and the name of the item (for example, ZC6) that is being displayed or edited. Main Display Area This area contains the main content for the particular screen. Th...
Page 12 - Enter Password Screen; Table 3: Three User Password Levels; Level; Default; Figure 4: Operator Password Entry Screen; Enter Operator password
System Manager/Zone Coordinator User’s Manual 12 428516-YUM-B-0908 Enter Password Screen The Password screen may appear when you attempt to change a value, request an addi-tion, or make a deletion. The password requires 4 digits. Once the system authenticates your password entry, the screen that you...
Page 13 - Default Passwords Provided; Home Screens; Table 4: List of Default Passwords; User Name; Guest; Table 5: Contents of Home Screen Display; Type of Information; Outdoor Air Temperature; Figure 5: Home Screens - System Manager and Zone Coordinator
System Manager/Zone Coordinator User’s Manual 13 428516-YUM-B-0908 Default Passwords Provided Several default passwords are defined from the factory. Each is listed as follows: Home Screens The Home screen appears when you first activate the System Manager or Zone Coor-dinator by touching its screen...
Page 14 - Display and Navigation Screens; Table 6: Buttons Available on Navigation Screens; Option button - changes the display to reflect this option.; Figure 6: Example of a Navigation Screen (System Manager Setup)
System Manager/Zone Coordinator User’s Manual 14 428516-YUM-B-0908 Display and Navigation Screens Display and Navigation screens allow you to navigate through the system. By pressing the appropriate button, you find the information or reach the data input screen you need. Figure 6 is an example of a...
Page 15 - Data Entry Screens; Back button - returns the display to the previous screen.; Figure 7: Example of a Data Entry Screen (Occupancy Time 1 Screen)
System Manager/Zone Coordinator User’s Manual 15 428516-YUM-B-0908 Data Entry Screens Data Entry screens on the System Manager/Coordinator enable you to perform opera-tions such as entering setup parameters, selecting from a list of options, and specifying time schedules. Figure 7 is an example of a...
Page 16 - Remote User Interface; You can disable remote system access see; Figure 8: Specifying User Name and Password in Browser
System Manager/Zone Coordinator User’s Manual 16 428516-YUM-B-0908 Remote User Interface The System Manager/Coordinator includes a remote user interface option allowing you to access the device remotely using Microsoft® Internet Explorer® Web browser on your computer. You simply enter the IP address...
Page 17 - Alarms and Alarm Priorities; Types of Alarms
System Manager/Zone Coordinator User’s Manual 17 428516-YUM-B-0908 Note: The user name and password screen in Figure 8 may also appear whenever you are logged on to the System Manager/Coordinator and access an operation, which requires user authentication such as changing your password. After you en...
Page 18 - Buffer Limitation; Alarm Destinations; Pagers
System Manager/Zone Coordinator User’s Manual 18 428516-YUM-B-0908 Buffer Limitation The Zone Coordinator holds the last 50 alarms in memory, whereas the System Man-ager keeps the last 150 alarms. When the buffer limit is reached, the newest alarm replaces the oldest alarm. All alarms kept at the Co...
Page 19 - Text Messages; Event Scheduling; Temporary Occupancy Override
System Manager/Zone Coordinator User’s Manual 19 428516-YUM-B-0908 over the active Internet connection to the Simple Mail Transfer Protocol (SMTP) server using the configured e-mail destination parameters. The SMTP server passes the message into the e-mail account specified. The time required for th...
Page 20 - All Schedules - Temporary Occupancy; Global and Instant Shutdown; Zone temperature
System Manager/Zone Coordinator User’s Manual 20 428516-YUM-B-0908 You can also force a single schedule, or all schedules, into the temporary occupancy state from the UI. This action places all members of the schedule into temporary occu-pancy. Members of the schedule can be a Group of zones or one ...
Page 21 - Time and Date; Display Units; Selecting Display Units; Table 8: Display Units on User Interface; Type; ppm
System Manager/Zone Coordinator User’s Manual 21 428516-YUM-B-0908 The System Manager and Coordinator also collect samples for the last 10 changes of the following outputs: • RTU fan status (On/Off) • Cool1 to Cool4 (On/Off) • Heat1 to Heat3 (On/Off) You can view this data in tabular format sorted b...
Page 22 - Maintenance Procedures
System Manager/Zone Coordinator User’s Manual 22 428516-YUM-B-0908 Maintenance Procedures The System Manager/Zone Coordinator includes the following maintenance proce-dures available to the operator: • Backup/Restore Configuration - copies the existing configuration (or restores a backed up configur...
Page 23 - Detailed Procedures; Basic Procedures; Waking up the Display; To enter your password:; Figure 9: Operator Password Entry Screen
System Manager/Zone Coordinator User’s Manual 23 428516-YUM-B-0908 Detailed Procedures Basic Procedures Basic procedures include waking up the display, entering your password, and logging on/logging off the remote user interface. Waking up the Display To wake up the System Manager/Coordinator when i...
Page 24 - Logging On the Remote User Interface; To log on the remote user interface:; Logging Off the Remote User Interface; Figure 10: Specifying User Name and Password in Browser
System Manager/Zone Coordinator User’s Manual 24 428516-YUM-B-0908 Logging On the Remote User Interface To log on the remote user interface: 1. Open your Internet browser and type the IP address of the System Manager/ Coordinator in the address bar. Example: http://192.254.12.3 2. Press Enter. A dia...
Page 25 - Setup Procedures; Figure 11: Setup Options - Menu Structure
System Manager/Zone Coordinator User’s Manual 25 428516-YUM-B-0908 Setup Procedures Setup procedures include: • Setting date and time parameters • Changing the administrator or operator password • Enabling/disabling the password requirement and remote user interface • Setting up the modem • Specifyi...
Page 26 - Setting Date and Time Parameters; To set date and time parameters:; Table 9: Time Management Parameters; Parameter; Current Date; Enabled or Disabled; Time Display; Figure 12: Time Management Screen; Time Management
System Manager/Zone Coordinator User’s Manual 26 428516-YUM-B-0908 Setting Date and Time Parameters To set date and time parameters: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. For a System Manager, press the System Manag...
Page 27 - Changing the Administrator or Operator Password; Change Operator Password; Figure 13: Password Definition Screen
System Manager/Zone Coordinator User’s Manual 27 428516-YUM-B-0908 5. Make the time parameter changes and press OK. The Time Management screen returns, reflecting the changes you made. Changing the Administrator or Operator Password To change the administrator or operator password: 1. From the Home ...
Page 28 - Enabling (or Disabling) Password Security; Coordinator Setup and Status screen appears.
System Manager/Zone Coordinator User’s Manual 28 428516-YUM-B-0908 5. Use the number keypad to specify a new password. Use any combination of 4 digits. Press the Clear button if you need to erase the digits and start over. As you enter the password, asterisks appear in the New Password field. 6. To ...
Page 29 - Enabling (or Disabling) the Remote User Interface; Figure 15: Remote User Interface Screen
System Manager/Zone Coordinator User’s Manual 29 428516-YUM-B-0908 5. To disable password security when the password requirement is currently enabled, press OK. To enable password security when the password requirement is currently disabled, press OK. The Security/Password Setup screen returns, indi...
Page 30 - Setting up a Modem; Modem Setup; Figure 16: Modem Setup Screen
System Manager/Zone Coordinator User’s Manual 30 428516-YUM-B-0908 5. To disable the remote user interface when the interface is currently enabled, press OK. To enable the remote user interface when the interface is currently disabled, press OK. The Security/Password Setup screen returns, indicating...
Page 31 - returns, reflecting the changes you made.; Specifying Ethernet Settings; To specify Ethernet settings:; Table 10: Modem Parameters; Allow Incoming Connections; Baud Rate; True or False; Extra Initialization Commands
System Manager/Zone Coordinator User’s Manual 31 428516-YUM-B-0908 4. Press the button for the modem parameter you want to change. The button label describes the current setting. When you press the button, the appropriate screen appears, allowing you to change the value. Table 10 lists these paramet...
Page 32 - Setup screen returns, reflecting the changes you made.; Table 11: Ethernet Parameters; Figure 17: Ethernet Setup Screen; Ethernet Setup
System Manager/Zone Coordinator User’s Manual 32 428516-YUM-B-0908 4. Press the Change Values button to enable editing of the parameters. The screen updates by displaying buttons that indicate the values you can change. 5. Press the button for the Ethernet parameter you want to change. The button la...
Page 33 - Figure 18: Display Units Setup Screen
System Manager/Zone Coordinator User’s Manual 33 428516-YUM-B-0908 Selecting Display Units To select Display units: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. For a System Manager, press the System Manager button. The Sy...
Page 34 - For a System Manager, press the System Manager button. The System; Figure 19: Calibrate Screen
System Manager/Zone Coordinator User’s Manual 34 428516-YUM-B-0908 2. For a System Manager, press the System Manager button. The System Manager Setup screen appears. For a Coordinator, press the Coordinator button. The Coordinator Setup screen appears. 3. Press the Display Setup button. The Display ...
Page 35 - Specifying System Manager/Zone Coordinator Name; System Manager Name; Figure 20: System Manager Name Entry Screen
System Manager/Zone Coordinator User’s Manual 35 428516-YUM-B-0908 Specifying System Manager/Zone Coordinator Name To specify the System Manager or Zone Coordinator name: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. For a ...
Page 36 - Entering Job Name; Figure 21: Job Name Entry Screen; Job Name
System Manager/Zone Coordinator User’s Manual 36 428516-YUM-B-0908 Entering Job Name To enter a job name: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. For a System Manager, press the System Manager button. The System Manag...
Page 37 - Scheduling Procedures
System Manager/Zone Coordinator User’s Manual 37 428516-YUM-B-0908 Scheduling Procedures Scheduling procedures include: • Adding a schedule • Deleting a schedule • Adding a member to a schedule • Deleting a member from a schedule • Configuring temporary occupancy • Beginning temporary occupancy • En...
Page 38 - Figure 22: Schedule Options - Menu Structures
System Manager/Zone Coordinator User’s Manual 38 428516-YUM-B-0908 Figure 22 is a flowchart of the Schedule menu structure for the System Manager. These menu selections are described in the sections that follow. A schedule option is also offered under the Setup menu. Figure 22: Schedule Options - Me...
Page 39 - Adding a Schedule; Schedules screen appears.; Email Setup; Figure 23: Daily Schedules Screen
System Manager/Zone Coordinator User’s Manual 39 428516-YUM-B-0908 Adding a Schedule To add a schedule: 1. From the Home screen of the System Manager, press the Schedule icon. The Schedules screen appears. 2. Press the Add Schedule button. The Daily Schedules screen appears. A weekday schedule is pr...
Page 40 - configuration screen for this schedule day appears.; Figure 24: Example Schedules Screen for Monday
System Manager/Zone Coordinator User’s Manual 40 428516-YUM-B-0908 3. Press the day of week button to define its occupied and unoccupied times. The configuration screen for this schedule day appears. 4. Enter up to two pairs of occupied/unoccupied times for this day of the week. 5. Once you have def...
Page 41 - Deleting a Schedule; To delete a schedule:; Figure 25: Delete Schedule Screen
System Manager/Zone Coordinator User’s Manual 41 428516-YUM-B-0908 Deleting a Schedule To delete a schedule: 1. From the Home screen of the System Manager, press the Schedule icon. The Schedules screen appears. 2. Select the Schedule you wish to delete; that schedule’s Daily Schedule appears. 3. Pre...
Page 42 - Adding a Member to a Schedule; To add a member to a schedule:; Figure 26: Select New Member Screen
System Manager/Zone Coordinator User’s Manual 42 428516-YUM-B-0908 Adding a Member to a Schedule To add a member to a schedule: 1. From the Home screen of the System Manager, press the Schedule icon. The Schedules screen appears. 2. Select the schedule to which you want to add members; that schedule...
Page 43 - Deleting a Member from a Schedule; To delete a member from a schedule:; Figure 27: Delete Member Screen
System Manager/Zone Coordinator User’s Manual 43 428516-YUM-B-0908 Deleting a Member from a Schedule To delete a member from a schedule: 1. From the Home screen of the System Manager, press the Schedule icon. The Schedules screen appears. 2. Select the schedule from which you want to delete a member...
Page 44 - Adding an Exception Schedule; To add an exception schedule:; Figure 28: Properties for Exception Screen
System Manager/Zone Coordinator User’s Manual 44 428516-YUM-B-0908 Adding an Exception Schedule To add an exception schedule: 1. From the Home screen of the System Manager, press the Schedule icon. The Schedules screen appears. 2. Select the schedule to which you want to add an exception. The Daily ...
Page 45 - after; Setting up Temporary Occupancy Time; Figure 29: Properties for Exception Definition Screen
System Manager/Zone Coordinator User’s Manual 45 428516-YUM-B-0908 5. Press Yes to create this exception and have it reoccur annually. Or click Continue to create the exception as a one-time event. The Properties for Exception definition screen appears. 6. Press on the Begin Date and End Date button...
Page 46 - Setup screen appears.; Beginning Temporary Occupancy of a Schedule; To begin temporary occupancy of a schedule:; Figure 30: Temporary Occupancy Setup Screen; Temporary Occupancy Time
System Manager/Zone Coordinator User’s Manual 46 428516-YUM-B-0908 3. Press the Temporary Occupancy Setup button. The Temporary Occupancy Setup screen appears. 4. Press the Temporary Occupancy Time button. The Temporary Occupancy Time screen appears. 5. Use the numeric keypad to enter a new temporar...
Page 47 - Ending Temporary Occupancy of a Schedule; To end temporary occupancy of a schedule:; Beginning or Ending Temporary Occupancy to All Schedules; To begin or end temporary occupancy for all schedules:
System Manager/Zone Coordinator User’s Manual 47 428516-YUM-B-0908 Ending Temporary Occupancy of a Schedule To end temporary occupancy of a schedule: 1. From the Home screen, press the Schedule icon. The Schedules screen appears. 2. Select the schedule to end temporary occupancy. The Daily Schedules...
Page 48 - Alarm Procedures; Figure 31: Alarm Options - Menu Structure
System Manager/Zone Coordinator User’s Manual 48 428516-YUM-B-0908 Alarm Procedures Alarm procedures include: • Configuring a pager alarm destination • Configuring an e-mail alarm destination • Configuring a text message alarm destination • Configuring alarm indicators • Viewing an alarm summary • D...
Page 49 - Configuring Pager as Alarm Destination; To configure a pager as an alarm destination:; Pager Phone Number; Pager Service Access Number; Enter a value up to 24 characters; Alarm Priority Required to Send Message to Pager; Service, Service Priority and Critical; Max Text Characters; Figure 32: Pager Setup Screen; Pager Setup
System Manager/Zone Coordinator User’s Manual 49 428516-YUM-B-0908 Configuring Pager as Alarm Destination To configure a pager as an alarm destination: 1. From the Home screen of the System Manager or Zone Coordinator, press the Alarm Summary icon. The Alarm Summary screen appears. 2. Press the Alar...
Page 50 - Configuring E-mail Account as Alarm Destination; To configure an e-mail account as an alarm destination:; Databits
System Manager/Zone Coordinator User’s Manual 50 428516-YUM-B-0908 5. Make the pager destination changes and press OK. The Pager Setup screen returns, reflecting the changes you made. Configuring E-mail Account as Alarm Destination To configure an e-mail account as an alarm destination: 1. From the ...
Page 51 - Configuring Text Message as Alarm Destination; To configure a text message as an alarm destination:; Table 13: E-mail Destination Setup Parameters; SMTP Server Host
System Manager/Zone Coordinator User’s Manual 51 428516-YUM-B-0908 4. Press the button for the e-mail parameter you want to change. The button label describes the current setting. When you press the button, the appropriate screen appears, allowing you to change the value. Table 13 lists these parame...
Page 52 - Phone Number; Enter domain up to 30 characters; Figure 34: Text Message Setup Screen; Text Message Setup
System Manager/Zone Coordinator User’s Manual 52 428516-YUM-B-0908 3. Press the Text Message Destination button. The Text Message Setup screen appears. 4. Press the button for the text message parameter you want to change. The button label describes the current setting. When you press the button, th...
Page 53 - Setting Alarm Indicators; To set alarm indicators:; SMTP Port; Yes or No; SMTP User Name; Enter SMTP User Name up to 24 characters; SMTP Password; This parameter appears only if Authentication Needed = Yes.
System Manager/Zone Coordinator User’s Manual 53 428516-YUM-B-0908 5. Make the text message destination changes and press OK. The Text Message Setup screen returns, reflecting the changes you made. Setting Alarm Indicators To set alarm indicators: 1. From the Home screen of the System Manager or Zon...
Page 54 - The Alarm Priority screen appears.; Alarm Priorities that Activate Alarm Indicators
System Manager/Zone Coordinator User’s Manual 54 428516-YUM-B-0908 4. Press the button for the Alarm Priority required to activate alarm indicators. The Alarm Priority screen appears. 5. Select from one of these options: • Service, Service Priority, and Critical • Service Priority and Critical • Cri...
Page 55 - Viewing an Alarm Summary; To view an alarm summary:; Figure 36: Alarm Summary Screen
System Manager/Zone Coordinator User’s Manual 55 428516-YUM-B-0908 Viewing an Alarm Summary To view an alarm summary: 1. From the Home screen of the System Manager, press the Alarm Summary icon. The Alarm Summary screen appears. The Alarms Summary lists the alarms that have been generated and not de...
Page 56 - Deleting One or All Alarms; To delete one or all alarms:; Figure 37: Alarms Detail Screen
System Manager/Zone Coordinator User’s Manual 56 428516-YUM-B-0908 Deleting One or All Alarms To delete one or all alarms: 1. From the Home screen of the System Manager, press the Alarm Summary icon. The Alarm Summary screen appears. 2. To delete all alarms shown in the Alarm Summary, press the Dele...
Page 57 - Summary Procedures; Summary procedures include:; Figure 38: Summary Options - Menu Structure
System Manager/Zone Coordinator User’s Manual 57 428516-YUM-B-0908 Summary Procedures Summary procedures include: • Viewing system summaries • Viewing trend data Summaries shown at the System Manager include all Zone Coordinators and CV RTUs. Summaries shown at the Zone Coordinator include its zones...
Page 58 - Viewing System Summaries; To view system summaries:; Figure 39: System Summary Screen
System Manager/Zone Coordinator User’s Manual 58 428516-YUM-B-0908 Viewing System Summaries To view system summaries: 1. From the Home screen, press the Summary icon. The System Manager Summary or Summary of Zone Controllers screen appears. 2. For a System Manager, select a Zone Coordinator by press...
Page 59 - Viewing Trend Data; From the Home screen, press the Summary icon. The System Manager; Figure 40: Trend Summary Screen; ZC6 - Zone Temperature Trend
System Manager/Zone Coordinator User’s Manual 59 428516-YUM-B-0908 Viewing Trend Data To view trend data: 1. From the Home screen, press the Summary icon. The System Manager Summary or Summary of Zone Controllers screen appears. 2. For a System Manager, select a Zone Coordinator by pressing its butt...
Page 60 - Zone Setup Procedures; Figure 41: Zone Setup Options - Menu Structure
System Manager/Zone Coordinator User’s Manual 60 428516-YUM-B-0908 Zone Setup Procedures Zone setup procedures include: • Setting up a zone • Editing zone name • Viewing zone status • Copying zone setup to all zones • Requesting global shutdown of all zones • Viewing device diagnostics for a zone Fi...
Page 61 - Setting Up a Changeover Bypass Zone; To set up a changeover bypass zone:; Figure 42: Zone Setup Screen
System Manager/Zone Coordinator User’s Manual 61 428516-YUM-B-0908 Setting Up a Changeover Bypass Zone To set up a changeover bypass zone: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. For a System Manager, press the System...
Page 62 - Setting Up a CV RTU Zone; To set up a CV RTU zone:; Table 15: Zone Setup Parameters
System Manager/Zone Coordinator User’s Manual 62 428516-YUM-B-0908 6. Press the button for the zone parameter you want to change. The button label describes the current setting. When you press the button, the appropriate screen appears, allowing you to change the value. Table 15 lists these paramete...
Page 63 - Press the Setup button. The CV RTU Zone Setup screen appears.; Table 16: CV RTU Zone Setup Parameters; Figure 43: CV RTU Zone Setup Screen; CV RTU 24 - Zone Setup
System Manager/Zone Coordinator User’s Manual 63 428516-YUM-B-0908 3. Press the Setup button. The CV RTU Zone Setup screen appears. 4. Press the button for the zone parameter you want to change. The button label describes the current setting. When you press the button, the appropriate screen appears...
Page 64 - Setting up a VAV RTU Zone; To set up a VAV RTU zone:; Figure 44: VAV RTU Zone Setup Screen
System Manager/Zone Coordinator User’s Manual 64 428516-YUM-B-0908 Setting up a VAV RTU Zone To set up a VAV RTU zone: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. For a System Manager, press the Systems button, then selec...
Page 65 - Table 17: VAV RTU Zone Setup Parameters
System Manager/Zone Coordinator User’s Manual 65 428516-YUM-B-0908 6. Press the button for the zone parameter you want to change. The button label describes the current setting. When you press the button, the appropriate screen appears allowing you to change the value. Table 17 lists these parameter...
Page 66 - Editing a Zone Name; Figure 45: Edit Zone Name Screen; Zone Name
System Manager/Zone Coordinator User’s Manual 66 428516-YUM-B-0908 Editing a Zone Name To edit a zone name: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. For a System Manager, press the Systems button, then select the coord...
Page 67 - Viewing Zone Status; Figure 46: Zone Status Screen
System Manager/Zone Coordinator User’s Manual 67 428516-YUM-B-0908 Viewing Zone Status To view zone status: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. For the System Manager, press the Systems button, select the coordina...
Page 68 - Copying Zone Setup to All Zones; To copy a zone setup to all zones:; Figure 47: Zone Setup Screen
System Manager/Zone Coordinator User’s Manual 68 428516-YUM-B-0908 Copying Zone Setup to All Zones To copy a zone setup to all zones: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. For the System Manager, press the Systems b...
Page 69 - Requesting Global Shutdown of all Zones in all Systems; To request a global shutdown of all zones in all systems:; Figure 48: Global Shutdown Screen; Instant Shutdown of All Systems
System Manager/Zone Coordinator User’s Manual 69 428516-YUM-B-0908 Requesting Global Shutdown of all Zones in all Systems To request a global shutdown of all zones in all systems: 1. From the Home screen of the System Manager, press the Setup icon. The Setup screen appears. 2. Press the Systems butt...
Page 70 - Viewing Device Diagnostics; To view device diagnostics:; Figure 49: Device Diagnostic Screen Example - CV RTU1; CV RTU1 - Diagnostic
System Manager/Zone Coordinator User’s Manual 70 428516-YUM-B-0908 Viewing Device Diagnostics To view device diagnostics: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. If you are at a System Manager, press the Systems butto...
Page 71 - Zoning System Setup Procedures; Zoning system setup procedures include:; Figure 50: Zoning System Setup Options - Menu Structure
System Manager/Zone Coordinator User’s Manual 71 428516-YUM-B-0908 Zoning System Setup Procedures Zoning system setup procedures include: • Setting up a zoning system • Viewing zoning system status • Requesting instant shutdown of a zoning system • Balancing a zoning system Figure 50 is a flowchart ...
Page 72 - Setting Up a Zoning System; To set up a zoning system:; Figure 51: Zoning System Setup Screen for CV/COB RTU
System Manager/Zone Coordinator User’s Manual 72 428516-YUM-B-0908 Setting Up a Zoning System To set up a zoning system: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. For a System Manager, press the Systems button, then sel...
Page 73 - Table 18: Zoning System Setup Parameters; Table 19: Zoning System Setup Parameters - VAV RTU
System Manager/Zone Coordinator User’s Manual 73 428516-YUM-B-0908 4. Press the button for the zoning system parameter you want to change. The button label describes the current setting. When you press the button, the appropriate screen appears allowing you to change the value. Table 18 (CV/COB RTU)...
Page 74 - Viewing Zoning System Status; To view zoning system status:; Figure 52: Zoning System Status Screen for CV/COB RTU
System Manager/Zone Coordinator User’s Manual 74 428516-YUM-B-0908 Viewing Zoning System Status To view zoning system status: 1. From the Home screen, press the Setup icon. The System Manager Setup or Coordinator Setup and Status screen appears. 2. For a System Manager, press the Systems button, the...
Page 75 - Requesting Instant Shutdown of a Zoning System; To request an instant shutdown of a zoning system:; Figure 53: Instant Shutdown Screen; Instant Shutdown of CV RTU24
System Manager/Zone Coordinator User’s Manual 75 428516-YUM-B-0908 Requesting Instant Shutdown of a Zoning System To request an instant shutdown of a zoning system: 1. On the System Manager or Coordinator, go to the Zoning System Setup screen (Figure 51). For steps, see Setting Up a Zoning System . ...
Page 76 - Balancing a Zoning System; To balance a zoning system:; Figure 54: Balance Mode Screen; Balance Mode
System Manager/Zone Coordinator User’s Manual 76 428516-YUM-B-0908 Balancing a Zoning System To balance a zoning system: 1. On the System Manager or Coordinator, go to the Zoning System Setup screen (Figure 51). For steps, see Setting Up a Zoning System . 2. Press the Balance System button. The Bala...
Page 77 - Auxiliary Points Setup Procedures; Auxiliary points setup procedures include:; Figure 55: Auxiliary Points Setup Options - Menu Structure
System Manager/Zone Coordinator User’s Manual 77 428516-YUM-B-0908 Auxiliary Points Setup Procedures Auxiliary points setup procedures include: • Setting up auxiliary points • Editing IOM Controller name • Viewing auxiliary point status • Viewing IOM Controller point trend data Figure 50 is a flowch...
Page 78 - Setting up Auxiliary Points; To set up auxiliary points:; IOM-1 Auxiliary Points Selection; Figure 56: IOM Auxiliary Points Selection Screen
System Manager/Zone Coordinator User’s Manual 78 428516-YUM-B-0908 Setting up Auxiliary Points To set up auxiliary points: 1. From the Home screen of the System Manager, press the Setup icon. The System Manager Setup screen appears. 2. Press the Auxiliary Points button. The Auxiliary Points Setup an...
Page 79 - The Instant Shutdown switch is reserved for BI1 on IOM address 4.
System Manager/Zone Coordinator User’s Manual 79 428516-YUM-B-0908 6. Enable the point by pressing the Not Used button. Click OK, then edit the point’s definition. If you want to change the Open and Closed text for a binary point, use the on-screen keyboard to enter a name, then click OK to save. Al...
Page 80 - Editing an IOM Controller Name; To edit an IOM Controller name:; Figure 57: Edit IOM Name Screen; IOM Name
System Manager/Zone Coordinator User’s Manual 80 428516-YUM-B-0908 Editing an IOM Controller Name To edit an IOM Controller name: 1. From the Home screen of the System Manager, press the Setup icon. The System Manager Setup screen appears. 2. Press the Auxiliary Points button. The Auxiliary Points S...
Page 81 - Viewing Auxiliary Points Status; To view auxiliary points status:; Figure 58: IOM Auxiliary Points Details Screen
System Manager/Zone Coordinator User’s Manual 81 428516-YUM-B-0908 Viewing Auxiliary Points Status To view auxiliary points status: 1. From the Home screen of the System Manager, press the Setup icon. The System Manager Setup screen appears. 2. Press the Auxiliary Points button. The Auxiliary Points...
Page 82 - Viewing IOM Controller Point Trend Data; Figure 59: IOM Trend Summary Screen; AI1 Trend
System Manager/Zone Coordinator User’s Manual 82 428516-YUM-B-0908 Viewing IOM Controller Point Trend Data To view IOM Controller point trend data: 1. From the Home screen of the System Manager, press the Setup icon. The System Manager Setup screen appears. 2. Press the Auxiliary Points button. The ...
Page 83 - Dial-up Communication Procedures; Dial-up communication procedures include:; Creating a Dial-up Connection; Log on the computer and go to Control Panel > Network Connections.; Figure 60: New Connection Type Window
System Manager/Zone Coordinator User’s Manual 83 428516-YUM-B-0908 Dial-up Communication Procedures Dial-up communication procedures include: • Creating a dial-up connection • Dialing up the System Manager or Coordinator These procedures apply to System Manager and Coordinator models with an interna...
Page 84 - Connect to the Internet; option and click Next. The Getting Ready; Set up my connection manually; option and click Next. The; Figure 61: Getting Ready Window
System Manager/Zone Coordinator User’s Manual 84 428516-YUM-B-0908 3. Select the Connect to the Internet option and click Next. The Getting Ready window appears. 4. Select the Set up my connection manually option and click Next. The Internet Connection window appears. Figure 61: Getting Ready Window...
Page 85 - Connection using a dial-up modem; Figure 63: Connection Name Window
System Manager/Zone Coordinator User’s Manual 85 428516-YUM-B-0908 5. Select the Connection using a dial-up modem option and click Next. The Connection Name window appears. 6. Specify a name that identifies this connection. This name does not need to match your Internet Service Provider (ISP) name. ...
Page 86 - Figure 65: Connection Availability Window
System Manager/Zone Coordinator User’s Manual 86 428516-YUM-B-0908 7. Specify the phone number for calling the modem at the System Manager or Coordinator. Click Next. The Connection Availability window appears. 8. Select either option and click Next. The Internet Account Information window appears. ...
Page 87 - Operator; for the user name. Specify the password. Deselect the two; Figure 67: Completing the New Connection Wizard
System Manager/Zone Coordinator User’s Manual 87 428516-YUM-B-0908 9. Enter Operator for the user name. Specify the password. Deselect the two options under the Confirm Password entry. Click Next. The Completing the New Connection Wizard window appears. Figure 67: Completing the New Connection Wizar...
Page 88 - Finish. The window for the new connection you defined appears.; Figure 68: New Connection Window
System Manager/Zone Coordinator User’s Manual 88 428516-YUM-B-0908 10. If you want a shortcut added to your desktop, click that option. Then click Finish. The window for the new connection you defined appears. 11. To test this new connection, click Dial. To complete this procedure, click Cancel. The...
Page 89 - Dialing up a System Manager or Coordinator; To dial-up a System Manager or Coordinator:; Figure 69: Connection Window
System Manager/Zone Coordinator User’s Manual 89 428516-YUM-B-0908 Dialing up a System Manager or Coordinator To dial-up a System Manager or Coordinator: 1. Using your computer, double-click the new connection you defined in Creating a Dial-up Connection . The Connection window appears. 2. Click Dia...
Page 90 - Maintenance procedures include:; Figure 70: Maintenance Options - Menu Structure
System Manager/Zone Coordinator User’s Manual 90 428516-YUM-B-0908 Maintenance Procedures Maintenance procedures include: • Backing up and restoring the current configuration • Restoring factory settings • Relearning connected devices • Restarting the System Manager/Zone Coordinator Figure 70 is a f...
Page 91 - Backing up Current Configuration; To back up the current configuration:; Backup in Progress - Please
System Manager/Zone Coordinator User’s Manual 91 428516-YUM-B-0908 Backing up Current Configuration To back up the current configuration: 1. From the Home screen, press the Setup icon. The Setup screen appears. 2. If you are at the System Manager, press the System Manager button. The System Manager ...
Page 92 - drive and store it in a safe location.; Restoring Configuration Information; To restore configuration information:; Figure 72: Restore from USB Flash Drive Screen (System Manager)
System Manager/Zone Coordinator User’s Manual 92 428516-YUM-B-0908 8. Press the OK button to return to the Backup/Restore screen. Remove the flash drive and store it in a safe location. Restoring Configuration Information To restore configuration information: 1. From the Home screen, press the Setup...
Page 93 - No USB Drive OR a backup for this
System Manager/Zone Coordinator User’s Manual 93 428516-YUM-B-0908 If you are restoring a Zone Coordinator, go to the location of the coordinator. (You cannot restore a coordinator from the System Manager’s USB flash drive.) Connect the USB flash drive with the backed up configuration to the coordin...
Page 94 - Restoring Factory Settings; To restore factory settings:; Restore of factory defaults is in progress.; appears. The process takes no longer than
System Manager/Zone Coordinator User’s Manual 94 428516-YUM-B-0908 Restoring Factory Settings To restore factory settings: 1. From the Home screen, press the Setup icon. The Setup screen appears. 2. If you are at the System Manager, press the System Manager button. The System Manager Setup screen ap...
Page 95 - Relearning Connected Devices; To relearn connected devices:; Relearn has been completed; appears after the
System Manager/Zone Coordinator User’s Manual 95 428516-YUM-B-0908 After the restore has completed successfully, the device restarts and the Home screen appears in a few moments. If the restore failed, a message appears to describe what you can do. Relearning Connected Devices To relearn connected d...
Page 96 - Copyright; Johnson Controls Unitary Products; Restarting the System Manager/Zone Coordinator; To restart the System Manager/Zone Coordinator:; Do you want to restart the device?; The restart process takes a few moments to complete.
Subject to change without notice. Printed in U.S.A. 428516-YUM-B-0908 Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: 428516-YUM-A-0808 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 Restarting the System Manager/Zone Coordinator To restart the System ...