York YHJF18 - Manual

York YHJF18

York YHJF18 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
Page: / 26

Table of Contents:

  • Page 2 – Johnson Controls Unitary Products; Physical and Electrical Data
  • Page 3 – System Charge for Various Matched Systems; Outdoor Unit
  • Page 4 – COOLING CAPACITY - With Air Handler Coils
  • Page 5 – COOLING CAPACITY - With High Efficiency Motor Furnaces
  • Page 6 – COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)
  • Page 7 – HEATING PERFORMANCE - With Air Handler
  • Page 8 – HEATING CAPACITY - With High Efficiency Motor Furnaces
  • Page 9 – HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
  • Page 10 – ACCESSORIES; Blower Time Delay
  • Page 11 – TYPICAL INSTALLATION; Size
  • Page 12 – COOLING PERFORMANCE DATA; CONDENSING UNIT MODEL NO. YHJF18S41S1
  • Page 13 – CONDENSING UNIT MODEL NO. YHJF24S41S1
  • Page 15 – CONDENSING UNIT MODEL NO. YHJF36S41S1
  • Page 16 – CONDENSING UNIT MODEL NO. YHJF42S41S1
  • Page 17 – CONDENSING UNIT MODEL NO. YHJF48S41S1
  • Page 18 – LOW CFM; COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION; CONDENSING UNIT MODEL NO. YHJF60S41S1
  • Page 19 – HIGH CFM; COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
  • Page 20 – HEATING PERFORMANCE DATA; CONDENSING UNIT MODEL NO
Loading the manual

TECHNICAL GUIDE

SPLIT-SYSTEM
HEAT PUMPS

14.5 SEER – R-410A

MODELS:
YHJF18 THRU 60
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at www.york.com

Additional rating information can be found at

www.ahridirectory.org

LISTED

ISO 9001

Certified Quality

Management System

510667-YTG-A-0409

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

The heat pump condensing unit is the outdoor part of a versatile
system of heating and air conditioning. It is designed to be cus-
tom-matched with one of UPG’s complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal appli-
cations to provide a complete system. Electric Heaters are
available, if required. Add-on coils are available for use with
upflow, downflow, or horizontal furnaces and air handlers. Many
matches meet Federal Tax Rebate program.

WARRANTY

Single Phase Units:
5-year limited parts warranty.

10-

year limited compressor warranty.

FEATURES

QUALITY CONDENSER COILS -

The coil is constructed of

copper tubing and enhanced aluminum fins for increased
efficiency and corrosion protection.

PROTECTED COMPRESSOR -

The complete scroll com-

pressor line is internally protected against high pressure,
temperature, and externally by a factory installed high pres-
sure switch. This is accomplished by the simultaneous oper-
ation of high pressure relief valve and a temperature sensor
which protects the compressor if undesirable operating con-
ditions occur. A liquid line filter-drier further protects the com-
pressor.

DURABLE FINISH -

The cabinet is made of pre-painted

steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.

LOWER INSTALLED COST -

Installation time and costs are

reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.

TOP DISCHARGE -

The warm air from the top mounted fan

is blown up away from the structure and any landscaping.
This allows compact location on multi-unit applications.

SWEPT FAN BLADE SOUND JACKET -

The upward air

flow carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and compres-
sor operating sounds. The swept wing fan blade and com-
pressor sound jacket futher reduce noise levels.

LOW MAINTENANCE -

Long life permanently lubricated

motor-bearings need no annual servicing.

EASY SERVICE ACCESS -

Fully exposed refrigerant con-

nections, and a single panel covering the electrical controls
make for easy servicing of the unit.

SECURED SERVICE VALVES -

Secured re-usable service

valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging.

U.L. and C.U.L. listed -

approved for outdoor application.

Agency Listed

-

U.L. and C.U.L. listed - approved for out-

door application. The unit is certified in accordance with the
Unitary Small Equipment cerification program, which is
based on ARI Standard 210/240.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Johnson Controls Unitary Products; Physical and Electrical Data

510667-YTG-A-0409 2 Johnson Controls Unitary Products All dimensions are in inches. They are subject to change with-out notice. Certified dimensions will be provided upon request. Physical and Electrical Data MODEL YHJF18 S41S1 YHJF24 S41S1 YHJF30 S41S1 YHJF36 S41S1 YHJF42 S41S1 YHJF48 S41S1 YHJF60 ...

Page 3 - System Charge for Various Matched Systems; Outdoor Unit

510667-YTG-A-0409 Johnson Controls Unitary Products 3 PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tubing. 2. Verify the TXV and additional charge required for specific evaporator c...

Page 4 - COOLING CAPACITY - With Air Handler Coils

510667-YTG-A-0409 4 Johnson Controls Unitary Products — = Not applicable. COOLING CAPACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 STAGE COOLING MODEL W RATED CFM NET MBH SEER EER TOTAL SENS. 14.5 SEER HP WITH MV - VARIABLE SPEED YHJF18S41S1 MV12B 17 FC/MC35B – 600 18.0 13.0 15....

Other York Models

All York Other