York H1CE150 - Manual

York H1CE150

York H1CE150 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – FIGURES; Description; TABLE OF CONTENTS
  • Page 3 – Use the following guidelines to select a suitable loca-; RIGGING AND HANDLING; MUST; INSTALLATION; TABLE 1; - UNIT APPLICATION DATA
  • Page 4 – TABLE 2
  • Page 5 – TABLE 3; - TYPICAL FIELD WIRING WITH KES/KEU AIR HANDLER; ISOLATION RELAY; TERMINALS; - TYPICAL WIRING WITH PUC FURNACE
  • Page 6 – - UNIT DIMENSIONS AND CLEARANCES; CLEARANCES
  • Page 7 – REFRIGERANT PIPING; LINE SIZING
  • Page 8 – TABLE 4; NOTE: Maximum line length for HCE150 is 150 feet.; TABLE 5
  • Page 9 – - COOLING CAPACITIES AND POWER REQUIREMENTS
  • Page 10 – EVACUATION AND CHARGING
  • Page 11 – EXTENDING THE SERVICE PORTS
  • Page 12 – - CHARGING CURVE HCE090
  • Page 13 – - CHARGING CURVE HCE150
  • Page 14 – CRANKCASE HEATER; OPERATION; temperature settings within the limitations of the system.
Loading the manual

GENERAL

These condensing units are designed for outdoor installation

on a roof or at ground level. Every unit is completely piped and

wired at the factory and is shipped ready for immediate installa-

tion. Only the liquid and suction lines to the evaporator coil, the

control wiring and the main power wiring are required to com-

plete the installation. Each unit is dehydrated, evacuated, leak

tested and pressure tested at 450 psig before being pressur-

ized with a holding charge of refrigerant-22 for shipment and/or

storage.
All controls are located in the front of the unit and are readily ac-

cessible for maintenance, adjustment and service. All wiring

(power and control) can be made through the front of the unit.
Refer to Table 7 for condenser cooling capacities and power re-

quirements.

REFERENCE

This instruction covers the installation and operation of the ba-

sic condensing unit. For information on the installation and op-

eration of the evaporator blower units, please refer to the

matching air handler installation manual.

Additional information on the design, installation, op-

eration and service of this equipment is available in the

following reference form.

550.23-N1.1V- Low Ambient Accessory

Replacement Parts:

Refer to Parts Manual for complete listing of replacement

parts on this equipment.

All forms may be ordered from:

Standard Register

Toll Free Telephone: 877-318-9675

Toll Free Fax: 877-379-7920

INSPECTION

As soon as a unit is received, it should be inspected for possible

damage during transit. If damage is evident, the extent of the

damage should be noted on the carrier's freight bill. A separate

request for inspection by the carrier's agent should be made in

writing. See Form 50.15-NM for more information.

Installer should pay particular attention to the words:

NOTE, CAUTION

and

WARNING

. Notes are intended to clarify or make the

installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that personal injury

and/or equipment damage may result if installation procedure is not handled properly.

MODELS H5CE090, H3CE120 & H1CE150

8.9 - 9.5 EER

®

INSTALLATION MANUAL

SUNLINE 2000

SPLIT-SYSTEM

CONDENSING UNITS

(AIR COOLED)

Supersedes: 035-15407-002-A-0304

035-15407-002-B-0404

CAUTION

THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE

WITH THE ENCLOSED INSTALLATION INSTRUCTIONS AND

ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES

INCLUDING, BUT NOT LIMITED TO, BUILDING, ELECTRICAL,

AND MECHANICAL CODES.

WARNING

INCORRECT INSTALLATION MAY CREATE A CONDITION

WHERE THE OPERATION OF THE PRODUCT COULD CAUSE

PERSONAL INJURY OR PROPERTY DAMAGE.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FIGURES; Description; TABLE OF CONTENTS

035-15407-002-B-0404 2 Unitary Products Group General................................................................................1Reference ............................................................................1Inspection .......................................................................

Page 3 - Use the following guidelines to select a suitable loca-; RIGGING AND HANDLING; MUST; INSTALLATION; TABLE 1; - UNIT APPLICATION DATA

LIMITATIONS These units must be installed in accordance with all national and local safety codes. If no local codes apply, installation must conform with the appropriate national codes. See Table 1 for Unit Application Data. Units are designed to meet National Safety Code Standards. If components ar...

Page 4 - TABLE 2

CLEARANCES All units require certain minimum clearances for proper opera- tion and service. Refer to Figure 4 for these clearances. WARNING: Do not permit overhanging structures or shrubs to obstruct condenser air discharge. Additional height may be required for snow clearance if winter operation is...

Other York Models

All York Other