Table of Contents:

  • Page 2 – Unitary Products Group; COOLING CAPACITY - Coil Only; Coil Only; AIR
  • Page 3 – COOLING CAPACITY - COIL ONLY
  • Page 4 – APPLICATION LIMITATIONS; Air flow must be within the minimum and maximum limits; UNCASED UPFLOW; ENTERING AIR TEMPERATURE LIMITS
  • Page 6 – PHYSICAL DATA; HORIZONTAL - DUCT TYPE
  • Page 7 – HORIZONTAL CASED TYPE
  • Page 8 – DIMENSIONS
  • Page 9 – G1UA UPFLOW CASED COIL
  • Page 10 – G1HD HORIZONTAL DUCT COIL
  • Page 11 – G2FD MULTI-POSITION “A” COIL
  • Page 12 – G1NA COIL
Loading the manual

TECHNICAL GUIDE

ADD - ON COILS

FOR USE WITH SPLIT-SYSTEM

COOLING & HEAT PUMPS

MODELS: GHD, GFD, GFA, GNA,

GUA & GHA

600 - 2000 CFM 2 - 5 TON COILS

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at www.york.com for the most
up-to-date technical information.

Additional rating information can be found at

www.ariprimenet.org.

HORIZONTAL

G1HD

FULL CASED

MULTI-POSITION

G2FD

UPFLOW UNCASED

G1NA

UPFLOW CASED

G1FA

HORIZONTAL CASED

G1HA

UPFLOW

G1UA

036-21145-003 Rev. A (0403)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

Heating

Air Conditioning

R

DESCRIPTION

These cooling and heat pump coils are designed to be
installed with UPG furnaces and to be matched with UPG
cooling and heat pump outdoor units. All coils are available
as sweat-connect models for your convenience and ease of
matching.

Upflow Coils -

Available in high-capacity models to match

any system and upflow furnace. Models available with factory
installed TXV or orifice metering system.

Multi-Position Coils -

Available in high-capacity models to

match any system and any multi-position furnace and air
handler. Models available with factory installed TXV or orifice
metering system.

Horizontal Duct Coils -

Available to match any cooling or

heat pump system and horizontal furnace. Field transition
may be required.

Dedicated Horizontal Cased Coils -

Available to match

most cooling or heat pump systems and any horizontal gas
furnace or modular air handler. For horizontal application
only. Models available with factory installed TXV or orifice
metering system.

FEATURES

Insulated Cabinet -

All evaporator coil cabinets are thermally

insulated to prevent sweating.

Internally Clean -

All evaporator coils are factory leak-

tested, dehydrated, sealed and shipped with a holding
charge.

Durable Finish -

Coil casings are made of pre-painted steel.

The pre-treated flat galvanized steel provides a better paint to
steel bond, which resists corrosion and rust creep.

Optimum Heat Transfer -

Using the latest in heat transfer

technology, staggered rows of rifled copper tubes are
mechanically expanded into aluminum fins to provide opti-
mum air to surface contact for ample moisture removal as
well as high performance ratings.

Optional Factory Installed Thermal Expansion Valve -

Provides flexibility to match high efficiency applications at a
lower installed cost.

Yorkmate Refrigerant Control -

Provides optimum system

performance and the flexibility to match coils with any effi-
ciency level cooling or heat pump system.

ACCESSORIES

Refer to Price Manual for specific model numbers.

TXV Kits

- Thermal expansion valve kits are available for

indoor coils to obtain specific system performance.

Horizontal Drain Pan Kits

- A field installed horizontal drain

pan kit (1HP0623BK or 1HP0628BK) is available for horizon-
tal applications on the multi-position coil. The full cased multi-
position coil is also available with a factory installed horizon-
tal drain pan option.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Unitary Products Group; COOLING CAPACITY - Coil Only; Coil Only; AIR

036-21145-003 Rev. A (0403) 2 Unitary Products Group COOLING CAPACITY - Coil Only * MODEL RATED CFM ENTERING AIR ° F (WET BULB) MBH @ EVAPORATOR TEMPERATURE AND CORRESPONDING PRESSURE °F / PSIG 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 UPFLOW "A" TYPE G1FA024S14(T) G1UA024S14 675 72 35.6 32.5 ...

Page 3 - COOLING CAPACITY - COIL ONLY

036-21145-003 Rev. A (0403) Unitary Products Group 3 Notes:• G2FD coils available with a factory installed horizontal drain pan option (H). • G2FD061H24 is only available with a factory mounted horizontal pan. (T) indicates models with factory installed thermal expansion valve. COOLING CAPACITY - CO...

Page 4 - APPLICATION LIMITATIONS; Air flow must be within the minimum and maximum limits; UNCASED UPFLOW; ENTERING AIR TEMPERATURE LIMITS

036-21145-003 Rev. A (0403) 4 Unitary Products Group NOTE: Do not exceed minimum/maximum CFM limits shown under Air Flow Data. APPLICATION LIMITATIONS These units must be installed in accordance with all nationaland local safety codes. Air flow must be within the minimum and maximum limits approved ...

Other York Models

All York Other