York F*FP - Manual

York F*FP

York F*FP – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – Unitary Products Group; DIMENSIONS; BOTTOM VIEW
  • Page 3 – COIL TECHNICAL DATA; Sweat; COOLING CAPACITY; Air
  • Page 4 – ACCESSORIES; Refer to Price Manual for specific model numbers.; VERTICAL SUSPENSION KIT; - The suspension kit is; BOLT-ON THERMAL EXPANSION VALVE; LIMITATIONS; Entering Air Temperature Limits; EXTENDED AIRFLOW DATA; Models
  • Page 5 – EXTENDED AIR FLOW DATA; APPLICATION FACTORS-RELATED CFM VS. ACTUAL CFM; Capacity Factor
  • Page 6 – EXTENDED AIR FLOW DATA - F4FV VARIABLE SPEED MODELS; ELECTRIC HEAT CFM; Normal
  • Page 7 – Physical and Electrical Data
  • Page 8 – KW & MBH CONVERSIONS - FOR TOTAL POWER INPUT REQUIREMENT
  • Page 11 – FIELD WIRING CONNECTION - COOLING ONLY
  • Page 12 – FIELD WIRING CONNECTIONS - SINGLE STAGE HEAT PUMP; for SEER enhancement.; Air Handler Control Wiring; on F4FV model
  • Page 13 – TYPICAL INSTALLATION; TYPICAL APPLICATIONS; (Must comply with water heater installation instructions)
  • Page 14 – NOTES
  • Page 16 – Copyright
Loading the manual

TECHNICAL GUIDE

SINGLE PIECE AIR HANDLERS

FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS

HEAT PUMP MODELS:

F*FP

VARIABLE SPEED MODEL:

F*FV

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at www.york.com

Additional rating information can be found at
www.ari.org/aridirectory.

ISO 9001

Certified Quality

Management System

295421-YTG-B-0707

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

This fan coil unit provides the flexibility for installation in any
upflow or horizontal application. These versatile models may
be used for split-system cooling or heat pump operation.
Compact cabinets along with return air options in both the
upflow and horizontal positions allow this unit to fit into tight
spaces such as attics, crawl spaces, and closets.

NOTE:

For matching condensing units and performance

data, refer to condenser technical guides.

FEATURES

CABINET

-The compact and sturdy cabinet is protected with

a durable, attractive finish to prevent rust. The cabinet is also
insulated to prevent cabinet sweating. F*FP and F*FV mod-
els have 3/4 inch insulation.

BLOWERS

- Blowers are sized to circulate air both quietly

and efficiently. The direct-drive, multi-speed motors provide a
selection of air volume to match any application. Motor
speeds may be selected via quick connect terminal at the
motor. Slide-out blower/motor assemblies provide for easy
servicing.

COILS

- Using the latest in heat transfer technology, the rifled

tube coil/aluminum fin coils produce high performance ratings
and provide long lasting quality. The coils are capable of bot-
tom return air in the upflow position, and right or left end
return air in the horizontal position.

FACTORY INSTALLED TXV -

Air handler models F*FP and

F*FV have factory installed TXV metering device.

ELECTRIC HEATERS

- Models providing up to 25kw of heat

are available as field installed accessories. Electric heaters
are available in both single and three phase.

EASY INSTALLATION

- These fan coil units are designed to

provide the lowest total installation cost. Accessible color
coded control wiring, top and side power wiring knockouts,
easy to install drain connections and electric heaters all com-
bine to minimize installed cost on every job.

CONTROL BOARD

- The control board is equipped with low

voltage terminal strips for easy installation. The control board
is also equipped with plug-in receptacles for the auxiliary
heaters.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Unitary Products Group; DIMENSIONS; BOTTOM VIEW

295421-YTG-B-0707 2 Unitary Products Group DIMENSIONS Model Dimensions Wiring K.O.s 1 1. Actual conduit size is shown in parenthesis.2. All models only available with factory installed horizontal drain pan. Refrigerant Connections Line Size A B C D E F J K Liquid Vapor Height Width Depth Power Contr...

Page 3 - COIL TECHNICAL DATA; Sweat; COOLING CAPACITY; Air

295421-YTG-B-0707 Unitary Products Group 3 COIL TECHNICAL DATA Models Application Refrigerant Connection Type Face Area (Sq. Ft.) Deep Rows Fins Per Inch Coil Slab Size Tube Geometry Tube Dia. Fin. Type Metering Device H W F4FP024H06T2A A/C & HP Sweat 3.40 2 14 14 17.5 1 x .886 3/8 Enhanced TXV-...

Page 4 - ACCESSORIES; Refer to Price Manual for specific model numbers.; VERTICAL SUSPENSION KIT; - The suspension kit is; BOLT-ON THERMAL EXPANSION VALVE; LIMITATIONS; Entering Air Temperature Limits; EXTENDED AIRFLOW DATA; Models

295421-YTG-B-0707 4 Unitary Products Group ACCESSORIES Refer to Price Manual for specific model numbers. VERTICAL SUSPENSION KIT - The suspension kit is designed to be used with all sizes of fan coil units wheneverthe application requires vertical suspension of the unit. ELECTRIC HEATERS - Models sh...

Other York Models