  • Page 2 – Unitary Products Group; Physical and Electrical Data; MODEL
  • Page 3 – Outdoor Unit; Indoor Coil; For Notes See Page 4.
  • Page 4 – * This loose coil match does not achieve 13 SEER.
  • Page 5 – Physical and Electrical Data - 3 Phase; DIMENSIONS; Unit
  • Page 7 – COOLING CAPACITY - With Air Handler Coils; For Notes See Page 8
  • Page 10 – COOLING CAPACITY - With Variable Speed Furnaces; For Notes See Page 11
  • Page 12 – HEATING PERFORMANCE - With Air Handler
  • Page 14 – HEATING PERFORMANCE - Upflow Furnace Coils; UNIT; no supplemental electric heat operation.
  • Page 15 – HEATING CAPACITY - With Variable Speed Furnaces; For Notes See Page 16.
  • Page 17 – ACCESSORIES; Blower Time Delay; SOUND POWER RATINGS; UNIT MODEL; Cooling; NOTE: ALL OUTDOOR WIRING
  • Page 18 – COOLING PERFORMANCE DATA; CONDENSER; ID CFM
  • Page 25 – HEATING PERFORMANCE DATA; ENTERING
  • Page 32 – Copyright; NOTES
Loading the manual

246819-BTG-H-0208

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

SPLIT-SYSTEM HEAT PUMPS

13 SEER – R-22

MODELS:
E*BD-F018 THRU 060
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)

E*BD-(T,W)036 THRU 060
(2.5 THRU 5 NOMINAL TONS, 3 PHASE)

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at www.york.com

Additional rating information can be found at
www.ahridirectory.org

LISTED

ISO 9001

Certified Quality

Management System

TECHNICAL
GUIDE

TECHNICAL
GUIDE

DESCRIPTION

The 13 SEER series heat pumps are designed for use with a
variety of UPG evaporator sections to suit any application
need. A full line of matching Add-On Coils are available for
use with upflow, downflow or horizontal furnaces. Matching
Air Handlers are also available for upflow, downflow or hori-
zontal installation to provide a complete system. Electric heat
may be installed in air handlers. All units are factory charged
to assure easy installation.

WARRANTY

Single Phase Units:

5-year limited parts warranty.

5-

year limited compressor warranty.

Three Phase Units:

1-year limited parts warranty.

5-

year limited compressor warranty.

FEATURES

DURABLE CONSTRUCTION -

The outdoor unit is con-

structed of pre-painted steel that offers tough protection
against corrosion and resists fading when exposed to sun-
light. Drain holes are incorporated into the base pan to per-
mit free drainage of moisture.

QUALITY COILS -

The coil is constructed of enhanced

copper tube and aluminum fins.

COIL PROTECTION -

Coils are protected from damage by

a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.

PROTECTED COMPRESSOR -

The hermetic compressor

is internally protected against high pressure and tempera-
ture by the simultaneous operation of a high pressure relief
valve and temperature sensors which stop the compressor
if operating temperatures go too high. Both protectors
reset automatically. A discharge line solid core filter drier
further protects the compressor.

Complete System Control –

These heat pumps utilize

the unique microprocessor defrost control system to pro-
vide optimal comfort and to monitor the overall system for
reliable operation. The defrost control system continuously
monitors the space environment to maintain optimum effi-
ciency. It initiates defrost only when necessary to further
reduce heating costs and improve reliability. In the event
improper operating conditions occur, the control will auto-
matically shut the system down to extend the life of the
heat pump. Rapid cycling is prevented by use of an inter-
nal anti-recycle timer.

LOW OPERATING SOUND LEVEL -

The compressor is

mounted on rubber isolators to reduce operating sounds.
The slow moving condenser fan keeps air turbulence and
sound to a low level.

EASY ACCESS -

Removable panel affords accessibility to

the electrical box.

FULLY CHARGED AND FACTORY WIRED -

to simply

installation and reduce labor costs. Only power supply and
control wiring and refrigerant lines must be connected. All
models are sweat connect with reusable service valves.

Factory tested

- to verify system operation and control

functioning before shipment.

U.L. and C.U.L.

listed - approved for outdoor application.

Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Unitary Products Group; Physical and Electrical Data; MODEL

246819-BTG-H-0208 2 Unitary Products Group All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. Physical and Electrical Data - 1 Phase MODEL EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060S Unit Suppl...

Page 3 - Outdoor Unit; Indoor Coil; For Notes See Page 4.

246819-BTG-H-0208 Unitary Products Group 3 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060S Required TXV 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1 Factory Charge, lbs-oz...

Page 4 - * This loose coil match does not achieve 13 SEER.

246819-BTG-H-0208 4 Unitary Products Group * This loose coil match does not achieve 13 SEER. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of inter- connecting line tubing. 2. Verify the orifice size and th...

Other York Models

All York Other