York DNP042 - Manual
York DNP042 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS; LIST OF FIGURES; 0 SIDE SUPPLY AIR BLOWER PERFORMANCE -; FIGURE 1 - PRODUCT NOMENCLATURE
- Page 3 – STANDARD FEATURES/BENEFITS
- Page 4 – FIELD-INSTALLED ACCESSORIES
- Page 6 – FIGURE 2 - UNIT COMPONENT LOCATION
- Page 8 – TABLE 3: DNP024 COOLING CAPACITIES - 2 TON; ALL SENSIBLE CAPACITY
- Page 11 – TABLE 5: DNP036 COOLING CAPACITIES - 3 TON
- Page 13 – TABLE 7: DNP048 COOLING CAPACITIES - 4 TON
- Page 14 – TABLE 8: DNP060 COOLING CAPACITIES - 5 TON
- Page 15 – TABLE 9: TWO TON AIR PERFORMANCE; SIDE SUPPLY AIR PERFORMANCE - 208 VOLT
- Page 17 – TABLE 11: BOTTOM SUPPLY AIR BLOWER PERFORMANCE - 208/230 VOLTS
- Page 18 – FIGURE 3 - FIELD WIRING DIAGRAM CONTROL WIRING; PROGRAMMABLE; THERMOSTAT
- Page 19 – FIGURE 4 - POWER WIRING FIELD DIAGRAM
- Page 20 – TABLE 15: UNIT DIMENSIONS FRONT
- Page 22 – FIGURE 8 - TYPICAL SLAB ON GROUND INSTALLATION
- Page 23 – FIGURE 10 - TYPICAL DUCT APPLICATIONS
- Page 24 – FIGURE 12 - ROOF CURB DIMENSIONS
- Page 26 – COOLING UNIT WITH GAS HEAT
- Page 32 – TYPICAL WIRING DIAGRAM NOTES; Motors are inherently protected.; FIGURE 21 - TYPICAL WIRING DIAGRAM LEGEND; Open all disconnects before servicing this unit.
- Page 33 – MECHANICAL SPECIFICATIONS; GENERAL; UNIT CABINET; Refrigerant Circuit and Refrigerant Safety Components:
- Page 34 – UNIT OPERATING CHARACTERISTICS
036-21366-007-A-1205
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
TECHNICAL GUIDE
AFFINITY™ SERIES
SINGLE PACKAGE GAS/ELECTRIC
AIR COOLED AIR CONDITIONERS
2 THRU 5 NOMINAL TON
DNP024, 030, 036, 042, 048 AND 060
13 SEER
®
DESCRIPTION
York
®
Affinity™ Series packaged cooling/heating air condi-
tioners are designed for outdoor installation. Only utility and
duct connections are required at the point of installation.
The gas-fired heaters have aluminized steel tubular heat
exchangers and hot surface to pilot ignition. They are avail-
able in natural gas with field conversion to propane.
FEATURING
•
FACTORY MOUNTED TXV
•
COOLING/GAS HEATING UNITS (NATURAL GAS OR
PROPANE)
•
LOW PROFILE
•
QUIET OPERATION
•
COMMON FOOTPRINT
•
OPTIONAL SLIDE IN MOTORIZED DAMPERS
•
OPTIONAL SLIDE IN ECONOMIZERS
•
OPTIONAL PROPANE CONVERSION KIT
•
OPTIONAL HIGH ALTITUDE CONVERSION KIT
(NATURAL GAS/PROPANE)
•
OPTIONAL LOW NOx KIT
•
FULL PERIMETER BASE RAILS
•
BOTTOM AND SIDE UTILITY CONNECTIONS
•
1” OR 2” CLEANABLE FILTERS STANDARD ON ALL
3 PHASE MODELS. OPTIONAL ON 1 PHASE MODELS
•
WARRANTY - 1 PHASE
•
10 year compressor
•
20 year heat exchanger
•
5 year other parts
•
WARRANTY - 3 PHASE
•
5 year compressor
•
10 year heat exchanger
•
1 year other parts
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
036-21366-007-A-1205 2 Unitary Products Group TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1STANDARD FEATURES/BENEFITS . . . . . . . . . . . . 3FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . . 4TYPICAL WIRING DIAGRAM NOTES . . . . . . . . . . 32MECHANICA...
036-21366-007-A-1205 Unitary Products Group 3 STANDARD FEATURES/BENEFITS OPERATING EFFICIENCY - All units provide high operating efficiencies and have a minimum AFUE of 80% and SEER of 13.0. All efficiencies exceed legislated minimum levels. ON SITE FLEXIBILITY - All model sizes share a common, comp...
036-21366-007-A-1205 4 Unitary Products Group FAN SYSTEM - All 2-1/2, 3, 3-1/2 and 4 ton models operate over a wide range of design conditions with a constant CFM, electrically commutated (ECM) fan motor. These units easily match all types of applications and provide greater on site flexibility to m...