York YCJF24 - Manual
York YCJF24 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Johnson Controls Unitary Products; Physical and Electrical Data
- Page 3 – Outdoor Unit; For notes see Page 4.
- Page 4 – the listed TXV
- Page 5 – COOLING CAPACITY - With Air Handler Coils; COIL
- Page 7 – COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
- Page 8 – With Variable Speed Furnaces; For notes see Page 9.
- Page 10 – For notes see Page 12.
- Page 12 – For notes see Page 14.
- Page 15 – For notes see Page 16.
- Page 17 – For notes see Page 18.
- Page 19 – ACCESSORIES; Refer to Price Manual for specific model numbers.; OFF CYCLE TIMER DELAY; prevent rapid recycling of the compressor.; ROOM THERMOSTATS; TYPICAL INSTALLATION; UNIT MODEL
- Page 20 – COOLING PERFORMANCE DATA
- Page 21 – Coil
TECHNICAL GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
14.5 SEER – R-410A
MODELS:
YCJF24 THRU 60
(2 THRU 5 NOMINAL TONS, 1 PHASE)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
ISO 9001
Certified Quality
Management System
LISTED
413437-YTG-C-0908
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 14.5 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be custom-
matched with one of UPG’s complete line of evaporator sec-
tions, with each serving a specific function. Matching Air Han-
dlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters are
available, if required. Add-on coils are available for use with
upflow, downflow, or horizontal furnaces and air handlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
10-
year limited compressor warranty.
FEATURES
•
QUALITY CONDENSER COILS -
The coil is constructed of
aluminum microchannel tubing and enhanced aluminum fins
for increased efficiency and corrosion protection.
•
PROTECTED COMPRESSOR -
The compressor is inter-
nally protected against high pressure and temperature and
externally by a factory installed high pressure switch. This
protects the compressor if undesirable operating conditions
occur. A liquid line filter-drier further protects the compressor.
•
DURABLE FINISH -
The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
•
LOWER INSTALLED COST -
Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
•
TOP DISCHARGE -
The warm air from the top mounted fan
is blown up away from the structure and any landscaping.
This allows compact location on multi-unit applications.
•
LOW OPERATING SOUND LEVEL -
The upward air flow
carries the normal operating noise away from the living area.
The rigid top panel effectively isolates any motor sound. Iso-
lated compressor mounts minimize compressor operating
sounds. Additional sound attenuation is provided by a swept-
wing fan blade and compressor blanket.
•
LOW MAINTENANCE -
Long life permanently lubricated
motor-bearings need no annual servicing.
•
EASY SERVICE ACCESS -
Fully exposed refrigerant con-
nections, and a single panel covering the electrical controls
make for easy servicing of the unit.
•
SECURED SERVICE VALVES -
Secured re-usable service
valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging.
•
U.L. and C.U.L. listed -
approved for outdoor application.
•
Agency Listed
-
U.L. and C.U.L. listed - approved for out-
door application. The unit is certified in accordance with the
Unitary Small Equipment cerification program, which is
based on ARI Standard 210/240.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
413437-YTG-C-0908 2 Johnson Controls Unitary Products All dimensions are in inches. They are subject to change with-out notice. Certified dimensions will be provided upon request. Physical and Electrical Data MODEL YCJF24S41S1 YCJF30S41S1 YCJF36S41S1 YCJF42S41S1 YCJF48S41S1 YCJF60S41S1 Unit Supply V...
413437-YTG-C-0908 Johnson Controls Unitary Products 3 Additional R-410A Charge / Orifice Size for Various Matched Systems Outdoor Unit YCJF24S41S1 YCJF30S41S1 YCJF36S41S1 YCJF42S41S1 YCJF48S41S1 YCJF60S41S1 Required Orifice or TXV 1 1TVM(902/4F1) 1TVM(903/4G1) 1TVM(903/4G1) 1TVM(903/4G1) 1TVM(905/4J...
413437-YTG-C-0908 4 Johnson Controls Unitary Products PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of intercon- necting line tubing. 2. Verify the TXV or orifice and additional charge required for specific...