York D2EG 048 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Unitary Products Group; INSTALLATION; E G; MAINTENANCE & TROUBLESHOOTING; FIGURES; No. Description Page; TABLE OF CONTENTS
- Page 3 – - UNIT APPLICATION DATA
- Page 5 – NOTE: There may be a local gas utility requirement specifying; - TYPICAL FIELD WIRING; Length in Feet; TABLE 3
- Page 6 – - EXTERNAL SUPPLY CONNECTION
- Page 7 – VENT AND COMBUSTION AIR HOODS; CAUTION: All three screws in the vent hood must be properly; OPTIONAL ECONOMIZER RAIN HOOD; NOTE: Sensor must be positioned so that the sensing ports; - VENT AND COMBUSTION AIR HOODS
- Page 8 – - ENTHALPY SET POINT ADJUSTMENT; TABLE 4
- Page 9 – TABLE 6
- Page 10 – TABLE 7
- Page 11 – TABLE 8
- Page 12 – REAR VIEW; DETAIL “A”; AIR FLOW LEGEND
- Page 13 – ton only) must be energized at least 10 hours before; COOLING SEQUENCE OF OPERATION; OPERATION; GAS MAIN
- Page 14 – HEAT ANTICIPATOR SETPOINTS; - LIMIT CONTROL SETTING; OPERATING INSTRUCTIONS; CONTROL; GAS VALVES
- Page 15 – - PROPER FLAME ADJUSTMENT; TURNS; CAUTION
- Page 16 – CHECKING GAS INPUT; - PRESSURE DROP ACROSS A DRY
- Page 17 – MAINTENANCE
- Page 18 – TROUBLESHOOTING
GENERAL
YORK Model DEG units are single package air conditioners with
gas heat designed for outdoor installation on a rooftop or a slab.
The units are completely assembled on rigid, permanently
attached base rails. All piping, refrigerant charge, and
electrical wiring is factory-installed and tested. The units
require only electric power, gas piping and duct connections
at the point of installation.
The gas-fired heaters have aluminized steel tubular heat
exchangers and spark ignition with intermittent pilot.
This appliance is not to be used for temporary heating of
buildings or structures under construction.
INSPECTION
As soon as a unit is received, it should be inspected for possible
damage during transit. If damage is evident, the extent of the
damage should be noted on the carrier's freight bill. A separate
request for inspection by the carrier's agent should be made in
writing. Refer to Form 50.15-NM for additional information.
REFERENCE
Additional information on the design, installation, operation
and service of this equipment is available in the following
reference forms:
•
55.70-N1
-General Installation
•
55.70-N2
-Pre-start & Post-start Check List
•
530.18-N1.2V
-Economizer Accessory
•
530.18-N1.13V -Man. Outdoor Air Damper Accy 0-35%
•
530.18-N1.14V -Man. Outdoor Air Damper Accy 0-100%
•
530.18-N1.12V -Motorized Outdoor Air Damper Accy.
•
530.18-N1.8V
-Coil Guard
•
530.18-N2.11V -Low NOx Accessory
•
530.18-N8.2V
-High Altitude Accy. (Natural Gas)
•
530.18-N8.3V
-High Altitude Accy. (Propane)
•
530.18-N8.4V
-Gas Piping Accessory
•
530.18-N8.12V -Propane Conversion Accessory
•
690.15-N25V
-Low Ambient Accessory
Renewal Parts:
•
Refer to Parts Manual for complete listing of replacement
parts on this equipment.
All forms referenced in this instruction may be ordered from:
Standard Register
Toll Free Tel.: 877-318-9675
Fax: 877-379-7920
APPROVALS
Design certified by CGA and UL listed as follows:
1. For use as a forced air furnace with cooling unit.
2. For outdoor installation only.
3. For installation directly on combustible flooring or, in the U.S.A.,
on wood flooring or Class A, B, or C roof covering material.
4. For use with natural gas and/or propane (LP) gas.
Not suitable for use with conventional venting systems.
SUNLINE PLUS
™
GAS / ELECTRIC
SINGLE PACKAGE AIR CONDITIONERS
INSTALLATION INSTRUCTION
Supersedes: 035-14832-002-A-0302
035-14832-003-A-0204
MODELS D2EG 048 & 060 and D3EG 036
(11 SEER)
Installer should pay particular attention to the words:
NOTE, CAUTION
and
WARNING
. Notes are intended to clarify or make
the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that personal in-
jury and/or equipment damage may result if installation procedure is not handled properly.
FOR YOUR SAFETY
Do not store or use gasoline or
other flammable vapors or liquids
in the vicinity of this or any other
appliance
.
If you smell gas:
1. Open windows
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
CAUTION
THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH THE ENCLOSED INSTALLATION INSTRUC-
TIONS AND ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED TO, BUILDING,
ELECTRICAL, AND MECHANICAL CODES
WARNING
INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD
CAUSE PERSONAL INJURY, PROPERTY DAMAGE AND/OR DEATH.
WARNING
DE-ENERGIZE THE ELECTRICAL POWER AND TURN OFF THE GAS SUPPLY TO THE UNIT BEFORE ATTEMPTING TO
INSPECT, REPAIR OR PERFORM MAINTENANCE TO THE UNIT.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
035-14832-003-A-0204 2 Unitary Products Group General................................................................................1 Inspection ............................................................................1 Reference .....................................................................
LIMITATIONS These units must be installed in accordance with the current edition of the following national and local safety codes:In the U.S.A.:1. National Electrical Code ANSI/NFPA No. 70.2. National Fuel Gas Code Z223.1.3. Gas-Fired Central Furnace Standard ANSI Z21.47-1993.4. Local gas utility re...
DISCONNECT SWITCH BRACKET FOR UNITS WITH OPTIONAL BELT-DRIVE BRACKET A special bracket for mounting a field-supplied disconnect switch is provided in each unit ordered with an optional belt- drive supply air blower. The bracket is shipped inside the blower compartment taped to the top of the blower ...