York D2CG 072 - Manual

York D2CG 072

York D2CG 072 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – FIGURES; No. Description Page; TABLE OF CONTENTS
  • Page 3 – INSTALLATION; UNIT SIZE; Unitary Products Group
  • Page 5 – GAS PIPING; CAUTION: Label all wires prior to disconnection when servic-; TYPICAL POWER WIRING; TABLE 3 - PIPE SIZING
  • Page 8 – TABLE 4 - STATIC RESISTANCES
  • Page 9 – FIG 8 - CENTER OF GRAVITY; TABLE 5 - PHYSICAL DATA; - Side Duct Connections
  • Page 10 – TABLE 8
  • Page 11 – TABLE 9
  • Page 12 – TABLE 12 - SUPERHEAT CHARGING TABLE FOR MODEL 036
  • Page 14 – REAR VIEW; CLEARANCES; AIR FLOW LEGEND; UTILITIES ENTRY DATA
  • Page 15 – A Suction Line Freezestat to protect against low evaporator; HEATING SEQUENCE OF OPERATION; The control circuit includes the following safety controls:; GAS MAIN; OPERATION
  • Page 17 – TURNS
  • Page 18 – CHECKING GAS INPUT; SECURE OWNER’S APPROVAL; FIG. 15 PRESSURE DROP vs SUPPLY AIR CFM; Seconds; TABLE 18 - GAS RATE - CUBIC FEET PER HOUR
  • Page 19 – NORMAL MAINTENANCE; MAINTENANCE
Loading the manual

GENERAL

YORK Model DCG units are single package air conditioners
with gas heat designed for outdoor installation on a roof top or
a slab.

The units are completely assembled on rigid, permanently
attached base rails. All piping, refrigerant charge, and electrical
wiring is factory-installed and tested. The units require only electric
power, gas piping and duct connections at the point of installation.

The gas-fired heaters have aluminized steel tubular heat
exchangers and spark ignition with intermittent pilot.

This appliance is not to be used for temporary heating of
buildings or structures under construction.

INSPECTION

As soon as a unit is received, it should be inspected for possible
damage during transit. If damage is evident, the extent of the
damage should be noted on the carrier’s freight bill. A separate
request for inspection by the carrier’s agent should be made in
writing. Refer to Form 50.15-NM for additional information.

REFERENCE

Additional information on the design, installation, operation and
service of this equipment is available in the following reference forms:

55.70-N1 -General Installation

55.70-N2 -Pre-start & Post-start Check List

530.18-N1.2V -Economizer Accessory

530.18-N1.13V -Man. Outdoor Air Damper Accy 0-35%

530.18-N1.14V -Man. Outdoor Air Damper Accy 0-100%

530.18-N1.12V -Motorized Outdoor Air Damper Accy.

530.18-N1.8V -Coil Guard

530.18-N2.11V -Low NOx Accessory

530.18-N8.2V -High Altitude Accy. (Natural Gas)

530.18-N8.3V -High Altitude Accy. (Propane)

530.18-N8.4V -Gas Piping Accessory

530.18-N8.12V -Propane Conversion Accessor

690.15-N25V -Low Ambient Accessory

Renewal Parts:

Refer to Parts Manual for complete listing of replacement
parts on this equipment.

All forms referenced in this instruction may be ordered from:

Publications Distribution Center
Unitary Products Group
P.O. Box 1592, York, PA 17405

APPROVALS

Design certified by CGA and UL listed as follows:

1. For use as a forced air furnace with cooling unit.
2. For outdoor installation only.
3. For installation directly on combustible flooring or, in the U.S.A.,
on wood flooring or Class A, B, or C roof covering material.
4. For use with natural gas and/or propane (LP) gas.

Not suitable for use with conventional venting systems.

®

SUNLINE 2000

GAS / ELECTRIC

SINGLE PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTION

Supersedes: 530.18-N8Y (295)

530.18-N8Y (1096)

035-14838

CAUTION

SCROLL COMPRESSORS
OPERATE IN ONLY ONE
DIRECTION.

If the compressor is
experiencing:

- low amperage draw

- similar discharge and
suction pressure

- increased noise level

It is operating in reverse.
Switch two line voltage
connections to correct.

Installer should pay particular attention to the words:

NOTE, CAUTION and WARNING. Notes are intended to clarify or make

the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that personal injury
and/or equipment damage may result if installation procedure is not handled properly.

CAUTION

THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH THE ENCLOSED INSTALLATION INSTRUCTIONS
AND ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED TO, BUILDING, ELECTRI-
CAL, AND MECHANICAL CODES

WARNING

INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD CAUSE
PERSONAL INJURY, PROPERTY DAMAGE AND/OR DEATH.

WARNING

DE-ENERGIZE THE ELECTRICAL POWER AND TURN OFF THE GAS SUPPLY TO THE UNIT BEFORE ATTEMPTING TO
INSPECT, REPAIR OR PERFORM MAINTENANCE TO THE UNIT.

MODELS D7CG 036, 048 & 060 (10 SEER)

MODEL D2CG 072 (9 EER)

(STYLE A & Belt Drive Option)

FOR YOUR SAFETY

Do not store or use gasoline or
other flammable vapors or liquids
in the vicinity of this or any other
appliance
.
If you smell gas:
1. Open windows
2. Don’t touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FIGURES; No. Description Page; TABLE OF CONTENTS

General ................................................................................ 1Inspection............................................................................. 1Reference ............................................................................ 1Approvals ..........................

Page 3 - INSTALLATION; UNIT SIZE; Unitary Products Group

LIMITATIONS These units must be installed in accordance with the currenteditions of the following national and local safety codes:In the U.S.A.: 1. National Electrical Code ANSI/NFPA No. 70. 2. National Fuel Gas Code Z223.1. 3. Gas-Fired Central Furnace Standard ANSI Z21.47-1993. 4. Local gas utilit...

Page 5 - GAS PIPING; CAUTION: Label all wires prior to disconnection when servic-; TYPICAL POWER WIRING; TABLE 3 - PIPE SIZING

DISCONNECT SWITCH BRACKET FOR UNITSWITH OPTIONAL BELT-DRIVE BLOWER A special bracket for mounting a field-supplied disconnectswitch is provided in each unit ordered with an optionalbelt-drive supply air blower. The bracket is shipped inside theblower compartment taped to the top of the blower housin...