York B1HH018 - Manual
York B1HH018 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; TABLE 1 - UNIT APPLICATION DATA; TABLE 2 - UNITS WEIGHTS
- Page 3 – Unitary Products Group
- Page 4 – PHYSICAL DATA; POWER WIRING; UNIT TERMINAL STRIP; CONTROL WIRING
- Page 12 – - SIDE AND BOTTOM SUPPLY AIR BLOWER PERFORMANCE
- Page 13 – ADDITIONAL STATIC PRESSURE RESISTANCE
- Page 14 – BACK; UNIT SIZE; FRONT
- Page 15 – SEQUENCE OF OPERATION
- Page 16 – When the demand for cooling has been satisfied, the 24; HEATING OPERATION; When the fan switch on the thermostat is in the “ON” posi-; SECURE OWNER'S APPROVAL
- Page 17 – NORMAL MAINTENANCE; WARNING: Prior to any of the following maintenance proce-; MAINTENANCE
- Page 18 – TROUBLESHOOTING; WARNING: Troubleshooting of components necessarily re-; ELEMENTARY DIAGRAM
- Page 19 – TYPICAL WIRING DIAGRAM LEGEND (See page 18); CAUTION - OPEN ALL DISCONNECTS
- Page 21 – TYPICAL WIRING DIAGRAM LEGEND (See page 20); C A U T I O N - O P E N A L L D I S C O N N E C T S
- Page 23 – TYPICAL WIRING DIAGRAM NOTES (See page 22)
- Page 26 – E L E M E N T A R Y D I A G R A M
GENERAL
YORK Model B1HH units are factory assembled heat pumps
designed for outdoor installation on a roof top or a slab. Field-
installed electric heater accessories are available to provide
supplemental electric heat combined with electric cooling and
heating.
The units are completely assembled on rigid, removable
base rails. All piping, refrigerant charge, and electrical wiring
is factory installed and tested. The units require only electric
power and duct connections at the point of installation.
The electric heaters have nickel-chrome resistance wire ele-
ments and utilize single point power connection.
INSPECTION
As soon as a unit is received, it should be inspected for possi-
ble damage during transit. If damage is evident, the extent of
the damage should be noted on the carrier's freight bill. A
separate request for inspection by the carrier's agent should
be made in writing. Refer to Form 50.15-NM for additional in-
formation.
REFERENCE
Additional information on the design, installation, operation
and service of this equipment is available in the following refer-
ence forms:
•
55.70-N1 — General Installation
•
55.70-N2 — Pre-start & Post-start Check List
•
511.26-N1.1V — Electric Heater Accessory
REPLACEMENT PARTS
•
Refer to Replacement Parts Manual for complete listing of
replacement parts on this equipment.
Installer should pay particular attention to the words: NOTE, CAUTION and WARNING. Notes are intended to clarify or make the
installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that personal injury
and/or equipment damage may result if installation procedure is not handled properly.
CAUTION
THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH THE ENCLOSED INSTALLATION INSTRUCTIONS
AND ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED TO, BUILDING, ELEC-
TRICAL, AND MECHANICAL CODES
WARNING
INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD CAUSE
PERSONAL INJURY, PROPERTY DAMAGE AND/OR DEATH.
WARNING
DE-ENERGIZE THE ELECTRICAL POWER TO THE UNIT BEFORE ATTEMPTING TO INSPECT, REPAIR OR PERFORM
MAINTENANCE TO THE UNIT.
CHAMPION
®
SERIES
SINGLE PACKAGE HEAT PUMPS
Supersedes: 66297-YIM-B-1004
66297-YIM-C-0205
INSTALLATION INSTRUCTION
®
MODELS B1HH018 THRU 060
1.5 THRU 5 TON
(12 SEER)
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
LIMITATIONS These units must be installed in accordance with the followingnational and local safety codes. 1. National Electrical Code ANSI/NFPS No. 70 or Canadian Electrical Code Part 1, C22.1 (latest editions). 2. Local plumbing and waste water codes and other applica- ble local codes. Refer to Ta...
CLEARANCES All units require certain clearances for proper operation andservice. Refer to Figure 3 for the clearances required for com-bustion, construction, servicing and proper unit operation. WARNING: Do not permit overhanging structures or shrubs to obstruct the condenser air discharge outlet. D...
66297-YIM-C-0205 4 Unitary Products Group TABLE 3 - PHYSICAL DATA MODELS BHH 018 024 030 036 042 048 060 INDOOR BLOWER CENTRIFUGAL BLOWER (Dia. x Wd. in.) 9 X 6 10 X 8 10 X 8 10 x 8 11 x 10 11 x 10 11 x 10 FAN MOTOR HP (Three Speed) ! " ! " ! " 1 INDOOR COIL ROWS DEEP 2 2 3 3 3 3 3 FINS ...