White Rodgers 36J27-554 - Manual
White Rodgers 36J27-554 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – MOUNTING POSITIONS
- Page 3 – CAUTION; PRECAUTIONS; Failure to turn off electric or main gas supply; WARNING
- Page 4 – INSTALLATION; . Turn off electrical power to the system at the; that; compound to the first two threads (see figure; SYSTEM WIRING; NOTE; – Typical Gas Valve Piping
- Page 6 – LIGHTING INSTRUCTIONS
- Page 7 – NOTES
- Page 10 – REMARQUES
- Page 11 – Si vous ne pouvez pas joindre le fourni; de le réparer appelez un technicien qualifié.; DIRECTIVES D’ ALLUMA
- Page 12 – INSTALLA
- Page 13 – CÂBLAGE; – Tuy
- Page 14 – PRÉCAUTIONS; POSITIONS DE MONTAGE
- Page 15 – 0 degrés de la position debout
- Page 16 – Vanne modulatrice à gaz; Vanne modulatrice à gaz combinée à ADE et à; DIRECTIVES D’INSTALLA; DESCRIPTION; PIÈCE N; Chute de pr
The
36J27
combination gas valve is designed for
direct spark ignition (DSI) and hot surface ignition
(HSI) system applications. This control is equipped
with redundant and main solenoid valves that control
gas flow to the main burners, a pressure regulator
and a two-position on/off switch for regulation
and electrical shut-off of the solenoid valves. Upon
signal from an integrated furnace control, the valve
modulates outlet pressure.
Fig.
1 – 36J27
Modulating Gas Valve
CONTROL LABEL
36
J
27-554
DSI and HSI Modulating Combination Gas Valve
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
SPECIFICATIONS
www.white-rodgers.com
www.emersonclimate.com
PART NO.
37-7004D
Replaces 37-7004C
1345
Pressure Regulator Adjustment Range ( inches W.C.)
Pipe Sizes
CSA Std. Gas
.64
Sp. Gr.
(
1000
BTU/CU. FT.)
LP Gas
1.53
Sp. Gr.
(
2500
BTU/CU. FT.)
Adjustment
Range
(NAT., IN. W.C.)
Adjustment
Range
(LP., IN. W.C.)
1/2” x 1/2”
NPT
20,000 – 210,000
BTU/HR
32,600 – 340,000
BTU/HR
0.40 – 4.0
1.3 – 11.5
For L.P. Gas Use Conversion Kit
F92-1021
1.0"
Pressure Drop Capacity
Pipe Sizes (NPT)
CSA Std. Gas
.64
Sp. Gr.
(
1000
BTU/CU. FT.)
LP Gas
1.53
Sp. Gr.
(
2500
BTU/CU. FT.)
1/2” x 1/2”
(Vertical or Upright)
140,000 BTU/HR
226,800 BTU/HR
CONTENTS
Description ................................................
1
Specifications
.............................................
1
Mounting Positions
......................................... 2
Precautions ................................................
3
Installation .................................................
4
System Wiring
Adjustment ................................................
5
Pressure Regulator Adjustment
Lighting Instructions....................................
6
Ambient Temperature
....
-40°
to
175°F
Pressure Rating
..............
14”
W.C. (
1⁄2
PSI) max.
Voltage
...........................
24
VAC
Frequency
.......................
60
Hz
Total Current
..................
1.0A
Pulse Width Modulation (PWM):
Low level:
0 – .03
volts
High level:
3 – 5.5
volts
Modulation
.....................
35% – 100%
opening
with
1%
increments
Regulator Vent Outlet
.... accepts
5/16"
I.D. hose
Rotary dip switch for pressure regulation adjustment
Precalibrated for LP – simplifies conversion
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 MOUNTING POSITIONS UPRIGHT, OR 0° TO 90° FROM UPRIGHT 3.000 MAX. SWING RADIUS Swing Radius Fig. 3 – Dimensions Length .................................. 4.75" Width ................................... 2.38" Height .................................. 4.58" Swing Radius .....................
3 CAUTION ! Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring can cause equipment damage, property damage, and/or personal injury.This control is not intended for use in locations where it may come in direct contact with water. Suitable protection must be ...
4 INSTALLATION 1 . Turn off electrical power to the system at the fuse box or circuit breaker. Also turn off the main gas supply. 2. If replacing an existing valve, disconnect all plumbing and electrical connections from the old control. 3. The control may be installed upright, + or – 90˚ from uprig...