White Rodgers 1F86-344 - Manual

White Rodgers 1F86-344

A user manual for the White-Rodgers 1F86-344 non-programmable digital thermostat covers its installation, operation, and safety requirements. The document includes essential topics like electrical specifications, wiring diagrams for HVAC systems (heat-only, heat/cool, or heat pump), and detailed instructions on adjusting settings such as heating/cooling modes, temperature units, and filter reminders. Safety warnings about voltage limits, mercury handling, and proper system configuration are also addressed to ensure safe use.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
Page: / 5

Table of Contents:

  • Page 1 – Installation and Safety Specifications
  • Page 2 – Thermostat Installation Procedures
  • Page 3 – HVAC Wiring Diagrams and Operational Instructions
  • Page 4 – Thermostat Operation and Configuration
  • Page 5 – Advanced Settings and Troubleshooting
Loading the manual
Page 1

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

Thermostat installation and all components of the
system shall conform to Class II circuits per the NEC
code.

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

Your new White-Rodgers Digital Thermostat uses the technol-
ogy of a solid-state microcomputer to provide precise tempera-
ture control.

Features:

• Simultaneous heat and cool setpoint storage
• Pre-set temperature control
• Backlit display
• LCD continuously displays setpoint and room temperature

• °F/°C convertibility
• Temperature range 45° to 90°F
• RC, RH, C, W, Y, G , O and B terminals
• Optional C terminal (Dual Power option)
• B and O terminals for single stage heat pumps (no auxiliary

heat) or damper operation

• Setpoint storage in case of power loss
• 2 "AA" Energizer

®

alkaline batteries included

SPECIFICATIONS

ELECTRICAL DATA

Electrical Rating:

8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA

Setpoint Temperature Range:

45°F to 90°F (7°C to 32°C)

Operating Ambient Temperature Range:

32°F to 105°F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-4°F to 150°F

APPLICATIONS

For use with:

Standard heat/cool or heat only systems

Electric heat systems

Gas or oil fired systems

Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers

Hydronic (hot water or steam) systems

Single-stage heat pump systems (no auxiliary heat)

Millivolt systems

DO NOT USE WITH:

Multi-stage systems

Systems exceeding 30 VAC and 1.5 amps

3-wire zoned hydronic heating systems

1F86-344

Non-Programmable Electronic Digital Thermostat

PART NO. 37-6585A

0515

INSTALLATION AND

OPERATION INSTRUCTIONS

PRECAUTIONS

CAUTION

!

This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.

WARNING

!

Operator: Save these instructions for future use!

White-Rodgers is a division

of Emerson Electric Co.

www.white-rodgers.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
White Rodgers
Model
1F86-344
Document type
Manual
Language(s)
English
Pages
5
File size
139.4 KB
Format
PDF

Summary

Page 1 - Installation and Safety Specifications

Instructions for installing the thermostat, detailing electrical and thermal specifications, safe wiring precautions, voltage limits, and approved applications.

Page 2 - Thermostat Installation Procedures

Steps for removing and installing the unit, handling batteries, configuring the device for electric heat/single-stage or hydronic heating systems, and safety warnings regarding mercury.

Page 3 - HVAC Wiring Diagrams and Operational Instructions

Wiring diagrams for various HVAC configurations including heat-only, heat/cool, and heat pump systems, along with operational instructions and safety cautions for system adjustment.

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.