  • Page 2 – INSTALLATION; REMOVE OLD THERMOSTAT; the labels enclosed with the new thermostat.; ATTACH THERMOSTAT BASE TO WALL; Figure 1. Back of thermostat base; Figure 2. Thermostat base
  • Page 3 – Relay contacts shown are thermostatically operated.; Figure 3. Typical wiring diagram for single transformer systems; CUT AND; NOTE
  • Page 4 – O/B TERMINAL SWITCH SELECTION; Fan Operation; while testing thermostat operation, simply press; CAUTION
  • Page 5 – OPERATION; THE THERMOSTAT BASE; The Thermostat Buttons and Switches; OPERATING FEATURES; C CONVERTIBILITY — Press SET TIME/SET TEMP
  • Page 6 – PROGRAMMING YOUR THERMOSTAT; ENTERING YOUR PROGRAM; Set Current Time and Day; Select Heating Temperatures; Heat Temperatures Cool Temperatures
  • Page 7 – Heating/Cooling Schedule Plan; SAMPLE
  • Page 8 – If the outside temperature is below 50; CHECK YOUR PROGRAMMING
Loading the manual

To prevent electrical shock and/or equipment damage
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

Printed in U.S.A.

WHITE-RODGERS

1F84-51

Programmable Electronic Digital

Heat Pump Thermostat

INSTALLATION AND

OPERATION INSTRUCTIONS

PART NO. 37-5739A

Replaces 37-5613C

9637

SPECIFICATIONS

PRECAUTIONS

DESCRIPTION

Your new White-Rodgers 7-Day Digital Heat Pump Thermostat
uses the technology of a solid-state microcomputer to provide
precise time/temperature control. This thermostat offers you the
flexibility to design heating and cooling programs that fit your
needs.

Features:

• Separate program for each day of the week

• Simultaneous heat and cool program storage

• Preprogrammed temperature control

• Four separate time/temperature settings per 24 hour period

• LCD continuously displays set point, and alternately dis-

plays time and room temperature

• Temperature override until next program period

• Manual program override (HOLD temperature)

°

F/

°

C convertibility

• Temperature range 45

°

to 90

°

F

• Eight terminals for single or two-transformer systems

• O/B terminal for heat pump systems

• Armchair Programming Capability

This thermostat is intended for use with a 24 volt system; do not
use this thermostat with a millivolt or line voltage system. If in
doubt about whether your wiring is millivolt, line, or low voltage,
have it inspected by a qualified heating and air conditioning
contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

CAUTION

!

ELECTRICAL DATA
Electrical Rating:

20 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA
Setpoint Temperature Range:

45

°

F to 90

°

F (7

°

C to 32

°

C)

Operating Ambient Temperature Range:

32

°

F to 105

°

F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-40

°

F to 150

°

F

APPLICATIONS
For use with:

• Heat pump systems with up to two stages heat, one stage

cool

DO NOT USE WITH:

• Millivolt systems
• Systems exceeding 30 VAC and 1.5 amps
• 3-wire zoned hydronic heating systems

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Operator: Save these instructions for future use!

WARNING

!

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; REMOVE OLD THERMOSTAT; the labels enclosed with the new thermostat.; ATTACH THERMOSTAT BASE TO WALL; Figure 1. Back of thermostat base; Figure 2. Thermostat base

2 INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the oldthermostat has a wall...

Page 3 - Relay contacts shown are thermostatically operated.; Figure 3. Typical wiring diagram for single transformer systems; CUT AND; NOTE

3 NOTE NOTE Relay contacts shown are thermostatically operated. The following wiring diagrams show typical terminal identifica-tion and wiring. For proper installation, refer to the originalmanufacturer's instructions. L R E 24 VAC 120 VAC Hot MALF FAN ON EMERGENCY SYSTEM MONITOR SWITCH FAN AUTO Hea...

Page 4 - O/B TERMINAL SWITCH SELECTION; Fan Operation; while testing thermostat operation, simply press; CAUTION

4 Heating System 1. Move SYSTEM switch to HEAT position. If the auxiliary heating system has a standing pilot, be sure to light it. 2. Press to adjust thermostat setting to 90 ° and hold for five seconds. Both stages of the heating system should begin tooperate. However, if the word HEAT is flashing...

Other White Rodgers Models