White Rodgers 1F80-51 - Manual

White Rodgers 1F80-51

White Rodgers 1F80-51 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – INSTALLATION; REMOVE OLD THERMOSTAT; labels enclosed with the new thermostat.; ELECTRIC HEAT OR SINGLE-STAGE; ATTACH THERMOSTAT BASE TO WALL; BATTERY LOCATION; NOTE; Figure 1. Back of thermostat base
  • Page 3 – Figure 7. Typical wiring diagram for; Figure 10. Typical wiring diagram for; CHECK THERMOSTAT OPERATION; Fan Operation
  • Page 4 – Cooling System; CAUTION; THE THERMOSTAT BASE; The Thermostat Buttons and Switches; OPERATION
  • Page 5 – OPERATING FEATURES; C CONVERTIBILITY — Press and hold SET TIME and; PROGRAMMING YOUR THERMOSTAT
  • Page 6 – Entering Your Program; Set Current Time and Day; Enter Heating Program; Enter Cooling Program; If the outside temperature is below 50; CHECK YOUR PROGRAMMING
Loading the manual

To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

Your new White-Rodgers 5-Day/2-Day Digital Thermostat uses
the technology of a solid-state microcomputer to provide pre-
cise time/temperature control. This thermostat offers you the
flexibility to design heating and cooling programs that fit your
needs.

Features:

• Battery powered (3 “AA” Energizer

®

alkaline batteries in-

cluded).

• Separate 5-day (weekday) and 2-day (weekend) programming

• Simultaneous heat and cool program storage

• Preprogrammed temperature control

• Four separate time/temperature settings per 24-hour period

• LCD continuously displays set point, and alternately dis-

plays time and room temperature

• Temperature override until next program period

• Manual program override (HOLD temperature)

• User may select either 12- or 24-hour clock display

°

F/

°

C convertibility

• Temperature range 45

°

to 90

°

F

• Standard five terminals for single or two-transformer sys-

tems

• B and O terminals for single stage heat pumps or damper

operation

SPECIFICATIONS

ELECTRICAL DATA

Electrical Rating:

8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA

Setpoint Temperature Range:

45

°

F to 90

°

F (7

°

C to 32

°

C)

Operating Ambient Temperature Range:

32

°

F to 105

°

F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-40

°

F to 150

°

F

APPLICATIONS

For use with:

Standard heat/cool or heat only systems

Electric heat systems

Gas or oil fired systems

Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers

Hydronic (hot water or steam) systems

Single-stage heat pump systems

Millivolt systems

DO NOT USE WITH:

Multi-stage systems

Systems exceeding 30 VAC and 1.5 amps

3-wire zoned hydronic heating systems

1F80-51

Programmable Electronic Digital Thermostat

Printed in U.S.A.

PART NO. 37-5285E

Replaces 37-5285D

0004

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

WHITE-RODGERS

INSTALLATION AND

OPERATION INSTRUCTIONS

PRECAUTIONS

CAUTION

!

This thermostat is intended for use with a low voltage system;
do not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contrac-
tor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes
and ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

WARNING

!

Operator: Save these instructions for future use!

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; REMOVE OLD THERMOSTAT; labels enclosed with the new thermostat.; ELECTRIC HEAT OR SINGLE-STAGE; ATTACH THERMOSTAT BASE TO WALL; BATTERY LOCATION; NOTE; Figure 1. Back of thermostat base

2 INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the oldthermostat has a wall...

Page 3 - Figure 7. Typical wiring diagram for; Figure 10. Typical wiring diagram for; CHECK THERMOSTAT OPERATION; Fan Operation

3 RH Y 24 VAC 120 VAC Hot Neutral THERMOSTAT SYSTEM G W Figure 8. Typical wiring diagram for heat/cool, 5-wire, two-transformer systems HEATING TRANSFORMER Heating System Fan Relay CoolingSystem RC 24 VAC 120 VAC Hot Neutral COOLING TRANSFORMER O B RH Y 24 VAC 120 VAC Hot Neutral THERMOSTAT SYSTEM G...

Page 4 - Cooling System; CAUTION; THE THERMOSTAT BASE; The Thermostat Buttons and Switches; OPERATION

4 Cooling System This thermostat has a built-in short-term (5-minute) time delay.This feature is activated after the compressor shuts down andthe setpoint is changed within the 5-minute period. During this5-minute period, COOL will flash on the display indicating thatthe thermostat has locked out th...

Other White Rodgers Models

All White Rodgers Other