White Rodgers 36H SERIES - Manual
White Rodgers 36H SERIES – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – PRECAUTIONS; WARNING
- Page 3 – INSTALLATION; MAIN PIPING CONNECTIONS; PILOT GAS CONNECTION; Loosen the pilot fitting until it is finger-tight.; NOTE
- Page 4 – PRESSURE REGULATOR ADJUSTMENT; ADJUSTMENT; SYSTEM WIRING
- Page 5 – PILOT FLAME ADJUSTMENT
- Page 6 – LIGHTING INSTRUCTIONS; FOR YOUR SAFETY
- Page 7 – PARA APAGAR EL GAS QUE LLEGA AL ARTEFACTO; PARA SU SEGURIDAD LEA ANTES DE USAR; INSTRUCCIONES DE USO; INSTRUCCIONES DE ENCENDIDO; P ARA
- Page 8 – AJUSTE; AJUSTE DE PRESIÓN DE SALIDA; AJUSTE DE LA LLAMA; Para REDUCIR la presión del piloto; NOTA
- Page 11 – ANTES DE INICIAR LA INST; PRECAUCIONES; ¡ADVER
- Page 12 – DESCRIPCIÓN; Válvula de gas combinada; INSTRUCCIONES P ARA; T emperatura ambiente:; T amaños de tuberías disponibles
PART NO. 37-6632B
Replaces 37-6632A
0927
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE IN-
STALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.
The 36H series combination gas valve is designed with redundant and main solenoid valves that control gas flow to the main
burners, a pressure regulator to maintain a constant outlet pressure, and a two position on/off switch for electrical shutoff.
Model numbers below include features as described:
DESCRIPTION
SPECIFICATIONS
36H SERIES
Combination Gas Valve
INSTALLATION INSTRUCTIONS
CONTENTS
Description ................................................................. 1
Specifications ............................................................. 1
Precautions ................................................................ 2
Installation .................................................................. 3
System Wiring
Adjustment ................................................................. 4
Pressure Regulator Adjustment
Lighting Instructions .................................................... 6
Type of Gas:
Natural Gas
Ambient Temperature:
-40° to 175°F
Pressure Rating:
14” W.C. (
1
⁄
2
PSI) max.
Voltage:
24 VAC
Frequency:
50/60 Hz
Current:
Single Stage - .410A
Two-Stage - .540A
MOUNTING POSITIONS:
Upright, or 0
°
to 90
°
from upright
UPRIGHT
LEFT or RIGHT
INLET BOSS
VERTICAL
Figure 1. Gas valve mounting positions
360˚
Model
No.
# of
Stages
Open
Characteristics
Proven
Pilot
36H22
1
Fast
NO
36H23
1
Slow
NO
36H32
1
Fast
YES
36H33
1
Slow
YES
36H54
2
Fast
NO
36H55
2
Slow
NO
36H64
2
Fast
YES
36H65
2
Slow
YES
Pressure Regulator Setting: (“ W.C.)
Single
Stage
Two Stage
Low
High
Min Diff.
Low to High
Natural Gas 2.5 - 5.0 1.0 - 3.5
2.5 - 5.0
1.5
LP Gas
7.0 - 12.0 4.0 - 9.5 8.0 - 12.0
2.5
PIPE SIZES/CAPACITIES
Pipe Sizes
Available (inches)
Capacity (BTU/hr) at 1”
pressure drop across valve
AGA Std. Nat. Gas
(1,000 btu/cu. ft.)
LP. Gas
(2,500 btu/cu. ft.)
3/4” x 3/4” NPT
300,000
486,000
1/2” x 3/4” NPT
260,000
421,000
1/2” x 1/2” NPT
170,000
275,400
www.white-rodgers.com
www.emerson.com
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
PRECAUTIONS 1. Failure to turn off electric or main gas supply to heating system could cause personal injury and/or property damage by shock, gas suffocation, fire, and/or explosion. 2. Do not use this control on circuits exceeding speci- fied voltage. Higher voltage will damage the control and may ...
INSTALLATION MAIN PIPING CONNECTIONS R e fe r t o w a r n i n g s a n d c a u t i o n s o n p a g e 2 b e fo r e attempting installation. All piping must comply with local codes, ordinances, and/or national fuel gas codes. 1. Turn off electrical power to the system at the fuse box or circuit breaker...
4 PRESSURE REGULATOR ADJUSTMENT These controls are shipped from the factory with the regulator set as specified on the control label. Consult the appliance rat-ing plate to ensure burner manifold pressure is as specified. If another outlet pressure is required, follow these steps. INSTALLATION Natur...