White Rodgers 36C94-303 - Manual
White Rodgers 36C94-303 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – PRECAUTIONS; CAUTION; WARNING; Figure 2. Typical Gas Valve Piping; Upright, 90° from upright or vertical; Figure 1. Mounting positions
- Page 3 – INSTALLATION; Pilot Gas Connection; sion kit installation instructions.; Outlet Pressure Adjustment; Do not force; Replace the barbed hose fitting. Cycle the valve two or; Pilot Gas Adjustment; To REDUCE pilot flame,; Old Terminals; SYSTEM WIRING; NOTE
- Page 4 – OPERATING INSTRUCTIONS; which automatically lights the burner. Do; TO TURN OFF GAS TO APPLIANCE; A. This appliance is equipped with an intermittent; FOR YOUR SAFETY; C. Do not use this appliance if any part has been; LIGHTING INSTRUCTIONS
36C94-303
Delay-Opening Combination Gas Valve
PART NO. 37-7086B
Replaces 37-7086A
1024
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
SPECIFICATIONS
PRECAUTIONS
36C94-303 is a direct replacement for 36C94-302, 36E93-301,
36E93-302, 36E93-303 and 36E93-304. The 36C94-303 com-
bination gas valve is designed for intermittent ignition system
applications. The valve is equipped with a redundant solenoid
Type of Gas: Natural gas
LP gas (use conversion kit)
Pressure Regulator Adjustment Range:
Nat. Gas – 2.5 to 5.0" W.C.
L.P. Gas – 7.0 to 12" W.C.
Pipe Size:
Inlet – 1/2" NPT
Outlet – 3/4" NPT
Capacity @ 1" pressure drop across valve:
230,000 BTU/HR of 0.64 SP GR.
1,000 BTU/CU. FT gas
Ambient Temperature: –40 to +175°F (–40 to 79°C)
Pressure Rating: 14" W.C. (1/2 PSI) max.
Electrical Rating: 24 VAC, 60 Hz, 0.6 A
Parts and Accessories:
F92-0656 - LP to Natural Gas Conversion Kit for use on
Single Stage 36C, D, E, F, G, H, J valves. Regulation range
2.5" to 5.0" W.C.
F92-0659 - Natural to Regulated LP Gas conversion Kit for
use on Single Stage 36C, D, E, F, G, H, J valves. Regulation
range 7.0" to 12.0" W.C.
www.white-rodgers.com
www.emersonclimate.com
valve that controls gas flow to the pilot and main burners, a main
valve that controls gas flow to the main burner, a pressure regula-
tor to maintain a constant outlet pressure, integral gas pressure
switch and a two position on/off switch for electrical shutoff.
WARNING
!
If you do not follow these instructions exactly, a fire or explosion
may
result causing property damage, personal injury or loss of life.
1. Failure to turn off electric or main gas supply to heating system could cause personal injury and/or property
damage by shock, gas suffocation, fire, and/or explosion.
2. Do not use this control on circuits exceeding specified voltage. Higher voltage will damage the control and
may cause shock or fire hazard.
3. NEVER USE FLAME OR ANY KIND OF SPARK TO CHECK FOR GAS LEAKS–COULD CAUSE FIRE AND/OR
EXPLOSION.
4. Do not use a control set for natural gas with LP gas, or a control set for LP gas with natural gas. Personal
injury and/or property damage, gas suffocation, fire, and/or explosion may result.
DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING PRECAUTIONS.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 1. Shut off power to the unit and install Lock-Out tag on all disconnects and breakers. 2. Turn off main gas supply line valve.3. Mark all wires going to the old valve with the terminal description that they are attached to. 4. If replacing an existing valve, disconnect all plumbing and electrical...
3 INSTALLATION Figure 5. Gas Valve, Top Figure 6. Gas Valve, Side Figure 7. Gas Valve, Outlet Side 1/4” X 3/16” TERMINAL ADAPTER PILOT ADJUSTING COVER SCREW .58 4.53 4.00 INLET 1/2"-14 N.P.T. THDS. WITH SCREEN INLET 1/8"-27 N.P.T. PRESSURE TAP 4.00 R SWING RADIUS BARBED HOSE FITTING MUST BE ...
OPERATING INSTRUCTIONS 1. STOP! Read the safety information above on this page. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by han...