Vanguard SDVBN(A) - Manual
Vanguard SDVBN(A) – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – CAST IRON STOVE AND BURNER SYSTEM; WARNING: Any change to; WARNINGS; DANGER: Carbon monoxide; Carbon Monoxide Poisoning:
- Page 3 – OWNER’S MANUAL; LOCAL CODES; OPERATION
- Page 4 – Figure 3 - Clearances for Standard Installation; Corner Installation; Figure 2 - Common Stove Locations; CAUTION: This stove creates
- Page 5 – STOVE BODY ASSEMBLY; Remove plastic bag from stove body.; Figure 7 - Laying Down Stove On Side; Continued
- Page 6 – Figure 12 - Attaching Stove Door; Attach stove door by inserting step bolt; Figure 10 - Attaching Stove Legs
- Page 7 – WARNING: Never touch the; For DA3610T, make sure the
- Page 8 – GENERAL VENTING; INSTALLING REAR COVER; Figure 17 - Installing Rear Cover; Screw
- Page 9 – Figure 18 - Minimum Clearances for Vent Terminations
- Page 10 – WARNING: This stove with; INSTALLATION PLANNING; For Horizontal Termination:; Installing Vent System in a Chase; WARNING: Never run the vent; For Vertical Termination:
- Page 11 – The location; WARNING: Do not recess vent; Figure 19 - Snorkel Termination; Snorkel; Figure 20 - Snorkel Termination with Drainage Pipe
- Page 12 – Vent Opening; Figure 22 - Vent Opening Requirements; Note; Figure 24 - Installing Vinyl Siding Standoff
- Page 13 – Elbow; Horizontal Venting; Venting with Two 90; Elbows
- Page 14 – Flat Ceiling Installation; Figure 30 - Offset with Wall Strap and 45; Elbows with Termination at 90
- Page 15 – Figure 31 - Installing Firestop; If an offset is needed to avoid; Cathedral Ceiling Installation; finished ceiling
- Page 17 – Vertical Venting; RVKBK Kit Shown; Number Description; Number Description
- Page 18 – Figure 39 - Gas Connection; Installation Items Needed; Cap Pipe Nipple Tee Joint; CHECK GAS TYPE
- Page 19 – WARNING: Never use an open; Manual Shutoff Valve; Figure 40 - Flexible Gas Line; Open lower door panel.
- Page 20 – Figure 41 - Manual Shutoff Valve; Open; Figure 42 - Checking Gas Joints for Propane/LP Gas Burner System; Gas Valve; Figure 43 - Checking Gas Joints for Natural Gas Burner System
- Page 21 – WARNING: Installation must; The wire must; Figure 45 - Back View of Thermostat Base; Terminal “W”; Set the temperature adjustment to the
- Page 22 – CAUTION: Do not operate this; Installing Remote Receiver; Figure 48 - Installing Battery in Receiver; Figure 49 - Installing Remote Receiver
- Page 23 – WARNING: Failure to position; WARNING: The glass door
- Page 24 – Figure 58 - Control Valve; Piezo Ignitor
- Page 25 – OPTIONAL REMOTE; Thermostat Control Operation; Lighting; GHRC Series Operation:; Variable Control Knob
- Page 26 – • turn burner system off (see To Turn Off; Figure 61 - Pilot Assembly; If you are using; Thermopile
- Page 27 – GLASS DOOR; ment Parts on page 31.; VENTING SYSTEM
- Page 28 – TROUBLESHOOTING; WARNING: Turn off burner; POSSIBLE CAUSE; nance, page 27) or replace pilot assembly; OBSERVED PROBLEM
- Page 29 – tenance, page 27) or replace burner orifice
- Page 31 – SERVICE HINTS; When Gas Pressure Is Too Low; WIRING DIAGRAM; CAUTION: Label all wires prior; PARTS UNDER WARRANTY; Blower
- Page 32 – SPECIFICATIONS
- Page 33 – ACCESSORIES
- Page 35 – PART NUMBER; PARTS LIST
- Page 37 – KEY; Bottom Door (Porcelain Enamel Teal Green); PARTS AVAILABLE — NOT SHOWN; Touch-up Paint Bottle with Brush (Porcelain Enamel Teal Green)
- Page 38 – For information about this warranty write:; INTERNATIONAL; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
CAST IRON STOVE AND DIRECT-VENT
(FREESTANDING FIREPLACE HEATER)
BURNER SYSTEM
®
OWNER’S OPERATION AND INSTALLATION MANUAL
NATURAL GAS BURNER SYSTEM MODEL SDVBN(A)
PROPANE/LP GAS BURNER SYSTEM MODEL SDVBP(A)
REMOTE READY
Save this manual for future reference.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s in-
structions.
• If you cannot reach your gas supplier, call the
fire department.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For as-
sistance or additional information
consult a qualified installer, ser-
vice agency, or the gas supplier.
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— Installation and service must
be performed by a qualified in-
staller, service agency, or the
gas supplier.
IMPORTANT: This direct-vent burner system must be installed into approved Vanguard cast
iron stove bodies, models SCIVF series and PSCIVF series ONLY. See page 3 of this manual.
This appliance may be installed in an aftermarket* manufactured (mobile) home,
where not prohibited by state or local codes.
— This appliance is only for use
with the type of gas indicated on
the rating plate. This appliance is
not convertible for use with other
gases, unless a certified kit is used.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) SAFETYINFORMATION 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases unless a certified kitis used. 2. For propane/LP burner system, do notpla...
3 105499 OWNER’S MANUAL P IL O T LO HI OFF ON ON OFF AUTO PRODUCTIDENTIFICATION Install and use stove and burner system withcare. Follow all local codes. In the absenceto local codes, use the current National FuelGas Code ANS Z223.1, also known asNFPA 54* (USA) or the current CAN/CGA-B149[.1 or .2] ...
4 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) LOCATION AND SPACEREQUIREMENTS Determine the safest and most efficient loca-tion for your Vanguard cast iron stove. Makesure that rafters and wall studs are not in theway of the venting system. Choose a locationwhere the heat output ...