Page 2 - CAST IRON STOVE AND BURNER SYSTEM; WARNING: Any change to; WARNINGS; DANGER: Carbon monoxide; Carbon Monoxide Poisoning:
2 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) SAFETYINFORMATION 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases unless a certified kitis used. 2. For propane/LP burner system, do notpla...
Page 3 - OWNER’S MANUAL; LOCAL CODES; OPERATION
3 105499 OWNER’S MANUAL P IL O T LO HI OFF ON ON OFF AUTO PRODUCTIDENTIFICATION Install and use stove and burner system withcare. Follow all local codes. In the absenceto local codes, use the current National FuelGas Code ANS Z223.1, also known asNFPA 54* (USA) or the current CAN/CGA-B149[.1 or .2] ...
Page 4 - Figure 3 - Clearances for Standard Installation; Corner Installation; Figure 2 - Common Stove Locations; CAUTION: This stove creates
4 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) LOCATION AND SPACEREQUIREMENTS Determine the safest and most efficient loca-tion for your Vanguard cast iron stove. Makesure that rafters and wall studs are not in theway of the venting system. Choose a locationwhere the heat output ...
Page 5 - STOVE BODY ASSEMBLY; Remove plastic bag from stove body.; Figure 7 - Laying Down Stove On Side; Continued
5 105499 OWNER’S MANUAL PalletWoodBolted toBottom ofStoveBody STOVE BODY ASSEMBLY 1. Lift off corrugated box enclosing stovebody crating. 2. Remove all screws fastening the woodframe enclosure. Spread wood frame openand lift away from plastic-bagged stovebody. The bottom pieces of pallet woodwill re...
Page 6 - Figure 12 - Attaching Stove Door; Attach stove door by inserting step bolt; Figure 10 - Attaching Stove Legs
6 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) CAST IRON STOVEAND DIRECT-VENTBURNER SYSTEMASSEMBLY Continued Figure 12 - Attaching Stove Door StepBolt DoorHinge ThreadedHole StoveDoor Stove Bottom BoltShoulder Adjusting Nut Bolt Stop Catch Bolt Door Claw Door Figure 13 - Catch Bo...
Page 7 - WARNING: Never touch the; For DA3610T, make sure the
7 105499 OWNER’S MANUAL WARNING: Never touch the blower wheel while in operation. 7. Peel off the backing paper and stick thesupplied wiring diagram decal on theinside of rear cover on right side oppo-site control. WARNING: Failure to position the parts in accordance with sup-plied diagrams or failu...
Page 8 - GENERAL VENTING; INSTALLING REAR COVER; Figure 17 - Installing Rear Cover; Screw
8 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) LOCATION OF VENTTERMINATION When locating vent termination, it is impor-tant to observe the minimum clearancesshown in Figure 18, page 9. *Check with local codes or with the currentCAN/CGA B149[.1 or .2] Installation Codesfor Canada ...
Page 9 - Figure 18 - Minimum Clearances for Vent Terminations
9 105499 OWNER’S MANUAL Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA(TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12 inches (...
Page 10 - WARNING: This stove with; INSTALLATION PLANNING; For Horizontal Termination:; Installing Vent System in a Chase; WARNING: Never run the vent; For Vertical Termination:
10 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) WARNING: Read all instruc- tions completely and thoroughlybefore attempting installation.Failure to do so could result inserious injury, property damageor loss of life. Operation of im-properly installed and maintainedventing system...
Page 11 - The location; WARNING: Do not recess vent; Figure 19 - Snorkel Termination; Snorkel; Figure 20 - Snorkel Termination with Drainage Pipe
11 105499 OWNER’S MANUAL INSTALLATION FORHORIZONTAL TERMINATION 1. Determine the route your horizontalventing will take. Note: The location of the horizontal vent termination onthe exterior wall must meet all local andnational building codes and must notbe easily blocked or obstructed. Snorkel termi...
Page 12 - Vent Opening; Figure 22 - Vent Opening Requirements; Note; Figure 24 - Installing Vinyl Siding Standoff
12 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) UP VENTINGINSTALLATION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1 / 2 " (190mm) Vent Opening Combustible Wall Vent Opening Noncombustible Wall Figure 22 - Vent Opening Requirements 3. Attach vent pipe assembl...
Page 13 - Elbow; Horizontal Venting; Venting with Two 90; Elbows
13 105499 OWNER’S MANUAL VENTINGINSTALLATION Continued Figure 26 - Horizontal TerminationConfiguration for Rigid Venting Figure 27 - Horizontal Termination Configuration for Rigid Venting Using One90 ° Elbow Horizontal Venting Vertical (V) Horizontal (H) 37" min. 29" max. (30 ° and 90 ° only...
Page 14 - Flat Ceiling Installation; Figure 30 - Offset with Wall Strap and 45; Elbows with Termination at 90
14 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) Flat Ceiling Installation 1. Cut a 10" square hole in the ceiling us-ing the locating hole as a center point.T h e o p e n i n g s h o u l d b e f r a m e d t o10"x10" (254mm x 254mm) inside di-mensions, as shown in Figu...
Page 15 - Figure 31 - Installing Firestop; If an offset is needed to avoid; Cathedral Ceiling Installation; finished ceiling
15 105499 OWNER’S MANUAL VENTINGINSTALLATION Continued Figure 31 - Installing Firestop If area above is not a room, installfirestop below framed hole. If area above is a room, install firestopabove framed hole. Continued 3. Cut a hole in the roof using the locatinghole as a center point. (Cover any ...
Page 17 - Vertical Venting; RVKBK Kit Shown; Number Description; Number Description
17 105499 OWNER’S MANUAL F i g u r e 3 7 - V e r t i c a l R i g i d V e n t i n gConfiguration With No Horizontal Run VENTINGINSTALLATION Continued Vertical Venting V = 40' max. RVKBK Kit Shown Note: Installrestrictor into 4"collar of burnersystem as shown. HIGH ALTITUDEINSTALLATION Your Vangua...
Page 18 - Figure 39 - Gas Connection; Installation Items Needed; Cap Pipe Nipple Tee Joint; CHECK GAS TYPE
18 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) Figure 39 - Gas Connection * The A.G.A. design-certified manual shutoff valve may be supplied with the appliance oryou can purchase it from your dealer. CAUTION: Use only new, black iron or steel pipe. Inter-nally-tinned copper tubi...
Page 19 - WARNING: Never use an open; Manual Shutoff Valve; Figure 40 - Flexible Gas Line; Open lower door panel.
19 105499 OWNER’S MANUAL Pressure Testing Gas SupplyPiping System Test Pressures In Excess Of 1/2 PSIG(3.5 kPa) 1. D i s c o n n e c t burner system a n d i t sindividual manual shutoff valve fromgas supply piping system. Pressures ine x c e s s o f 1 / 2 p s i g ( 3 . 5 k P a ) w i l ldamage burner...
Page 20 - Figure 41 - Manual Shutoff Valve; Open; Figure 42 - Checking Gas Joints for Propane/LP Gas Burner System; Gas Valve; Figure 43 - Checking Gas Joints for Natural Gas Burner System
20 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) STOVE ANDDIRECT-VENTBURNER SYSTEMINSTALLATION Continued Test Pressures Equal To or Less Than 1/2PSIG (3.5 kPa) 1. Close manual shutoff valve (see Fig-ure 41). 2. Pressurize supply piping system by ei-ther opening propane/LP supply t...
Page 21 - WARNING: Installation must; The wire must; Figure 45 - Back View of Thermostat Base; Terminal “W”; Set the temperature adjustment to the
21 105499 OWNER’S MANUAL STOVE ANDDIRECT-VENTBURNER SYSTEMINSTALLATION Continued INSTALLING OPTIONALWALL MOUNTEDTHERMOSTAT - GWMT1 WARNING: Installation must be done by a qualified installerfamiliar with low voltage wiringprocedures. WARNING: Do not connect this thermostat to any electricalsource! E...
Page 22 - CAUTION: Do not operate this; Installing Remote Receiver; Figure 48 - Installing Battery in Receiver; Figure 49 - Installing Remote Receiver
22 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) REMOVING/REPLACINGGLASS DOOR CAUTION: Do not operate this burner system with a brokenglass door panel or without theglass door panel securely inplace. For replacement part in-f o r m a t i o n s e e R e p l a c e m e n t Parts, page...
Page 23 - WARNING: Failure to position; WARNING: The glass door
23 105499 OWNER’S MANUAL Each log is marked with a number. Thesenumbers will help you identify the log wheninstalling. It is very important to installthese logs exactly as instructed. Do notmodify logs. Only use logs supplied withfreestanding burner system. Do not use ifany log(s) are broken (see Re...
Page 24 - Figure 58 - Control Valve; Piezo Ignitor
24 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) TO TURN OFF GAS TO APPLIANCE 1. Open lower louver panel. 2a. Turn ON/OFF switch to “OFF”. 2b. If Using Optional Hand-Held Re-mote: Set selector switch in the OFF position to prevent draining battery. 3. Turn off all electrical power...
Page 25 - OPTIONAL REMOTE; Thermostat Control Operation; Lighting; GHRC Series Operation:; Variable Control Knob
25 105499 OWNER’S MANUAL 1. After lighting, let pilot flame burn forabout one minute. Turn gas controlknob on the control valve to ON posi-tion. Turn variable control knob any-where between HI and LO. Slide theselector switch to the REMOTE posi-tion. Note: The burners may light if hand-held remote O...
Page 26 - • turn burner system off (see To Turn Off; Figure 61 - Pilot Assembly; If you are using; Thermopile
26 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) INSPECTINGBURNERS Check pilot flame pattern and burner flamepatterns often. PILOT ASSEMBLY The pilot assembly is factory preset for theproper flame height. Alterations may haveoccurred during shipping and handling. Calla qualified s...
Page 27 - GLASS DOOR; ment Parts on page 31.; VENTING SYSTEM
27 105499 OWNER’S MANUAL CLEANING ANDMAINTENANCE WARNING: Turn off burner s y s t e m a n d l e t c o o l b e f o r ecleaning. CAUTION: You must keep control areas, burners, and cir-culating air passageways ofburner system and stove clean.Inspect these areas of burnersystem and stove before eachuse....
Page 28 - TROUBLESHOOTING; WARNING: Turn off burner; POSSIBLE CAUSE; nance, page 27) or replace pilot assembly; OBSERVED PROBLEM
28 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off burner system and let cool before ser-vicing. Only a qualified serviceperson should service and repairburner system or stove. CAUTIO...
Page 29 - tenance, page 27) or replace burner orifice
29 105499 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Burner system produces a whistling noisewhen burner is lit Glass soots Burner system produces a clicking/tickin...
Page 31 - SERVICE HINTS; When Gas Pressure Is Too Low; WIRING DIAGRAM; CAUTION: Label all wires prior; PARTS UNDER WARRANTY; Blower
31 105499 OWNER’S MANUAL SERVICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit • burners will have delayed ignition • burner system will not produce speci- fied heat • propane/LP gas supply might be low (propane/LP units only) When Gas Quality Is Bad • pilot will not stay lit • burner...
Page 32 - SPECIFICATIONS
32 ® CAST IRON STOVE AND BURNER SYSTEM 105499 SDVBN(A) AND SDVBP(A) SPECIFICATIONS SDVBN(A) SDVBP(A) 16,000-22,000 Btu/h 14,000-20,000 Btu/h Gas Type Natural Propane/LP Ignition Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.c. Ther...
Page 33 - ACCESSORIES
33 105499 OWNER’S MANUAL ACCESSORIES Purchase these stove and burner systemaccessories from your local dealer. If theycan not supply these accessories, call DESAInternational’s Sales Department at 1-800-432-2382. for information. You can alsowrite to the address listed on the back pageof this manual...
Page 35 - PART NUMBER; PARTS LIST
35 105499 OWNER’S MANUAL KEYNO. PART NUMBER DESCRIPTION QTY. 1 105478-01BR Firebox Assembly 1 2 M11084-26 Screw, Hex 2 3 105482-01CK Rear Cover 1 4 M11084-39 Screw, Hex 12 5 103587-02CK Switch Plate 1 6 099998-01 On/Off Switch 1 7 103284-04 Wire Harness 1 8 104491-01 Relief Cover 1 9 104518-01 Relie...
Page 37 - KEY; Bottom Door (Porcelain Enamel Teal Green); PARTS AVAILABLE — NOT SHOWN; Touch-up Paint Bottle with Brush (Porcelain Enamel Teal Green)
37 105499 OWNER’S MANUAL PARTS LIST AMITY™SCIVF(*) SERIESPSCIVF(*) SERIES (* Indicates Color Suffix Designation) This list contains replaceable parts used in your stove. When ordering parts, follow the instructionslisted under Replacement Parts on page 31 of this manual. * Included In Hardware Kit K...
Page 38 - For information about this warranty write:; INTERNATIONAL; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
VANGUARD LIMITED WARRANTY DIRECT-VENT BURNER SYSTEM AND AMITY ™ STOVE CHASSIS DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of firstpurchase, provided that the product has been properly installed, operated and maintained...