Table of Contents:

  • Page 2 – B-VENT FREESTANDING FIREPLACE; WARNING: Any change to; WARNINGS; DANGER: Carbon monoxide
  • Page 3 – OWNER’S MANUAL; American National Standards Institute, Inc.; LOCAL CODES; OPERATION
  • Page 4 – Figure 3 - Clearances for Standard Installation
  • Page 5 – STOVE BODY ASSEMBLY; Remove plastic bag from stove body.; Figure 7 - Laying Down Stove On Side; Bolt; Figure 4 - Clearance for Corner Installation; Continued
  • Page 6 – Figure 12 - Attaching Stove Door; Attach stove door by inserting step bolt; Figure 10 - Attaching Stove Legs
  • Page 7 – WARNING: Never touch the; Plug in blower power cord.
  • Page 8 – INSTALLATION PRECAUTIONS; Figure 17 - Installing Rear Cover; Screw; WARNING: This gas fireplace
  • Page 9 – WARNING: Installation should; • Venting instruction contained in this; Figure 21 - Venting Through a Side Wall
  • Page 10 – Figure 22 - Test for Proper Venting; CHIMNEYS
  • Page 11 – • Using a draft meter to determine if; FLUE GAS SPILLAGE
  • Page 12 – Installation Items Needed; CHECK GAS TYPE
  • Page 13 – WARNING: Never use an open; Open lower door panel.; Flare Union; Figure 27 - Attaching Flexible Gas Lines Together; Figure 26 - Gas Connection; Cap Pipe Nipple Tee Joint
  • Page 14 – Close manual shutoff valve (see; Figure 28 - Manual Shutoff Valve; Open
  • Page 15 – WARNING: Installation must; The wire; WARNING: Do not connect; Figure 32 - Back View of Thermostat Base; Set the temperature adjustment to the
  • Page 16 – CAUTION: Do not operate this; Installing Remote Receiver; Figure 35 - Installing Battery in Receiver; Figure 36 - Installing Remote Receiver
  • Page 17 – WARNING: Failure to position; WARNING: The glass door
  • Page 18 – Figure 45 - Control Valve; Piezo Ignitor
  • Page 19 – OPTIONAL REMOTE; Thermostat Control Operation; Lighting; GHRC Series Operation:; Flame Adjustment Knob
  • Page 20 – • turn fireplace off (see To Turn Off Gas to; Figure 49 - Pilot Assembly; Thermopile; If you are
  • Page 21 – GLASS DOOR; ment Parts on page 25.; VENTING SYSTEM
  • Page 22 – TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; nance, page 21) or replace pilot assembly; OBSERVED PROBLEM
  • Page 23 – tenance, page 21) or replace burner orifice
  • Page 25 – SERVICE HINTS; When Gas Pressure is Too Low:; WIRING DIAGRAM; CAUTION: Label all wires prior; Use only original replacement parts.; PARTS UNDER WARRANTY; Blower
  • Page 26 – SPECIFICATIONS
  • Page 27 – ACCESSORIES
  • Page 29 – PART NUMBER; PARTS LIST
  • Page 31 – KEY; Bottom Door (Porcelain Enamel Teal Green); PARTS AVAILABLE — NOT SHOWN; Touch-up Paint Bottle with Brush (Porcelain Enamel Teal Green)
  • Page 32 – For information about this warranty write:; INTERNATIONAL; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
Loading the manual

CAST IRON STOVE

B-VENT FREESTANDING

FIREPLACE HEATER

®

OWNER’S OPERATION AND INSTALLATION MANUAL

®

SBVBN(A), SBVBP(A)

REMOTE READY

Save this manual for future reference.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

WARNING: Improper instal-
lation, adjustment, altera-
tion, service, or maintenance
can cause injury or property
damage. Refer to this manual
for correct installation and
operational procedures. For
assistance or additional in-
formation consult a quali-
f i e d i n s t a l l e r , s e r v i c e
agency, or the gas supplier.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by
state or local codes.
*

Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.

— Installation and service
must be performed by a
qualified installer, service
agency, or the gas supplier.

IMPORTANT: This fireplace must be installed into approved Vanguard cast iron stove bodies,

models SCIVF series and PSCIVF series ONLY. See page 3 of this manual.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - B-VENT FREESTANDING FIREPLACE; WARNING: Any change to; WARNINGS; DANGER: Carbon monoxide

2 ® B-VENT FREESTANDING FIREPLACE 105500 SAFETYINFORMATION 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases unless a certified kitis used. 2. For propane/LP fireplace, do not placepropane/LP supply tank(s) i...

Page 3 - OWNER’S MANUAL; American National Standards Institute, Inc.; LOCAL CODES; OPERATION

3 105500 OWNER’S MANUAL P IL O T LO HI OFF ON ON OFF AUTO PRODUCTIDENTIFICATION Install and use fireplace with care. Followall local codes. In the absence to local codes,use the current National Fuel Gas CodeANS Z223.1, also known as NFPA 54*(USA) or the current CAN/CGA-B149[.1 or.2] Installation Co...

Page 4 - Figure 3 - Clearances for Standard Installation

4 ® B-VENT FREESTANDING FIREPLACE 105500 LOCATION AND SPACEREQUIREMENTS Determine the safest and most efficient loca-tion for your Vanguard B-vent freestandingfireplace. Make sure that rafters and wallstuds are not in the way of the venting system.Choose a location where the heat output isnot affect...

Other Vanguard Models