Vanguard 18" - Manual

Vanguard 18

Vanguard 18" – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
Page: / 26

Table of Contents:

  • Page 2 – UNVENTED PROPANE/LP GAS LOG HEATER; DANGER: Carbon monoxide; WARNINGS; WARNING: Any change to this
  • Page 3 – OWNER’S MANUAL; LOCAL CODES; OPERATION; UNPACKING; CAUTION: Do not remove the; Figure 1 - Product Identification; Golden Oak Logs
  • Page 4 – Unusually Tight Construction; per
  • Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
  • Page 6 – Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings for; Figure 2 - Ventilation Air from Inside Building
  • Page 7 – LOG SIZING REQUIREMENTS; B. Clearances from the top of the fireplace; INSTALLATION; CHECK GAS TYPE
  • Page 8 – If Not Using Mantel; If you cannot meet these; If Using Mantel; Noncombustible material OK.
  • Page 9 – Figure 7 - Minimum Mantel Clearances When Using Hood; Figure 6 - Minimum Mantel Clearances Without Using Hood; MANTEL CLEARANCES; FLOOR CLEARANCES; A. If installing appliance on the floor level,; flue damper open
  • Page 10 – Installation Items Needed; Figure 10 - Attaching Damper Clamp; Masonry Fireplace
  • Page 11 – CAUTION: Never connect; • external regulator (supplied by installer,; WARNING: Never connect; Attach base assembly to fireplace floor; CAUTION: Avoid damage to
  • Page 12 – Figure 15 - Manual Shutoff Valve; WARNING: Never use an open; Correct all leaks at once.; Figure 14 - Gas Connection; Open propane supply tank valve.
  • Page 13 – WARNING: Failure to position; INSTALLING LOGS; Make sure; Figure 17 - Installing Golden Oak One-Piece Log Set; CAUTION: After installation
  • Page 14 – FOR YOUR SAFETY; • If fireplace has glass doors,
  • Page 15 – CAUTION: Do not try to adjust; Shutting Off Heater; Lighting; Do not leave the se-; GHRCT Operation
  • Page 16 – This remote control; Figure 23 - Correct Pilot Flame Pattern; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to; BURNER PRIMARY AIR HOLES; To turn the pilot off,
  • Page 17 – TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in
  • Page 18 – OBSERVED PROBLEM; tenance, page 21) or replace burner orifice
  • Page 19 – WARNING: If you smell gas; IMPORTANT
  • Page 20 – SPECIFICATIONS; Golden Oak; PARTS UNDER WARRANTY; SERVICE HINTS; When Gas Pressure Is Too Low; WIRING DIAGRAM; Note
  • Page 21 – Figure 26 - Pilot Inlet Air Hole; LOGS; • If you remove logs for cleaning, refer to; MAIN BURNER
  • Page 23 – PARTS LIST; KEY
  • Page 24 – ACCESSORIES; FIREPLACE HOOD
  • Page 25 – NOTES
  • Page 26 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; INTERNATIONAL; NOT A UPC
Loading the manual

UNVENTED (VENT-FREE)

PROPANE/LP GAS LOG HEATER

Variable Manually-Controlled Models Also

Design-Certified As Vented Decorative Appliances

®

Save this manual for future reference.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state
or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

®

Patent Pending

PIL

O T

O

F

F

O

N

LO

REMOTE

OFF

HI

FLAME-MAX

®

Golden Oak Log

Design

18", 24", 30", and 36"

Remote Ready Model

OWNER’S OPERATION AND INSTALLATION MANUAL

WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.

— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do
not use any phone in your building.

Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.

If you cannot reach your gas sup-
plier, call the fire department.

— Installation and service must be per-

formed by a qualified installer, ser-
vice agency, or the gas supplier.

WARNING: Improper installation, ad-
justment, alteration, service, or mainte-
nance can cause injury or property dam-
age. Refer to this manual for correct
installation and operational procedures.
For assistance or additional informa-
tion consult a qualified installer, ser-
vice agency, or the gas supplier.

WARNING: This appliance is for in-
stallation only in a solid-fuel burning
masonry or UL127 factory-built fire-
place, or in an approved ventless fire-
box. It is design certified for these
installations in accordance with ANS
Z21.11.2. Exception: Do not install this
appliance in a factory-built fireplace
that includes instructions stating it
has not been tested or should not be
used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to

Air for Combustion and Ventilation section on page 4 of this manual.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - UNVENTED PROPANE/LP GAS LOG HEATER; DANGER: Carbon monoxide; WARNINGS; WARNING: Any change to this

2 104309 UNVENTED PROPANE/LP GAS LOG HEATER VANGUARD FLAME-MAX ® SAFETYINFORMATION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re-semble the flu, with headaches, dizziness,or nausea. If you have these signs, the heatermay n...

Page 3 - OWNER’S MANUAL; LOCAL CODES; OPERATION; UNPACKING; CAUTION: Do not remove the; Figure 1 - Product Identification; Golden Oak Logs

3 104309 OWNER’S MANUAL PRODUCTIDENTIFICATION LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode ANS Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 B...

Page 4 - Unusually Tight Construction; per

4 104309 UNVENTED PROPANE/LP GAS LOG HEATER VANGUARD FLAME-MAX ® PROVIDING ADEQUATEVENTILATION The following are excerpts from NationalFuel Gas Code. NFPA 54/ANS Z223.1, Sec-tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the threefollowing ventilation classificati...

Other Vanguard Models

All Vanguard Other