Vanguard VMH10TNB - Manual
Vanguard VMH10TNB – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – VENT-FREE NATURAL GAS COMPACT FIREPLACE; Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide
- Page 3 – OWNER’S MANUAL; LOCAL CODES; American National Standards Institute, Inc.; Figure 1 - Vent-Free Natural Gas Compact Fireplace; SAFETY PILOT; UNPACKING; The fireplace; Figure 2 - Removing Fireplace Hood
- Page 4 – ASSEMBLY; ASSEMBLING FIREPLACE; • Phillips screwdriver; Installing Log; Lift screen up and pull out to remove.; Figure 3 - Assembling Fireplace; W A R N I N G : A l w a y s h a v e; Assembling Hood; Figure 4 - Assembling Hood
- Page 5 – Unusually Tight Construction; per
- Page 6 – DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION; Determining if You Have a Confined or Unconfined Space
- Page 7 – Ventilation Air From Outdoors; Do not provide openings for
- Page 8 – CAUTION: If you install the; • where there is easy access for operation,; CAUTION: This heater creates; Your Vanguard fireplace is designed; CHECK GAS TYPE; Only use; WARNING: Never install the; INSTALLATION
- Page 9 – Install fireplace near an
- Page 10 – Refer to instructions provided with; Attach wood base to floor with two 1; Figure 13 - Attaching Brass Trim to Fireplace; able height
- Page 11 – Repeat steps 1 through 6 for other corner.; Figure 15 - Assembling Brass Trim; Lift screen off heater.; Removing Valve Cover Shield; Do not remove shoul-; Figure 17 - Removing Valve Cover Shield; Installing Blower Assembly; CAUTION: Label all wires; If you are using a mantel with your
- Page 12 – Figure 18 - Installing Blower Bracket Assembly; When switch is in the
- Page 13 – For Built-In Installation; Reinstall valve cover shield.; Figure 21 - Installing Blower Bracket Assembly; Extension Cord
- Page 14 – Check gas line pressure be-; WARNING: Never connect; Floor anchors and mounting screws; Figure 22 - Folding Anchor; Figure 23 - Gas Connection
- Page 15 – Figure 24 - Removing Log Base Assembly From Fireplace; Installation Items Needed; Figure 25 - Attaching Flexible Gas Lines Together
- Page 16 – Figure 26 - Equipment Shutoff Valve; WARNING: Never use an open; Correct all leaks at once.
- Page 17 – CAUTION: Do not try to adjust; FOR YOUR SAFETY; WARNING: You must operate
- Page 18 – Thermostat Control Operation; The thermostat sensing bulb mea-; Shutting Off Fireplace; Turn control knob clockwise
- Page 19 – BURNER FLAME PATTERN; Figure 33 - Correct Burner Flame Pattern; PILOT FLAME PATTERN; • turn fireplace off (see To Turn Off Gas to
- Page 20 – TROUBLESHOOTING; POSSIBLE CAUSE; All troubleshooting items are listed in
- Page 21 – OBSERVED PROBLEM; nance, page 23) or replace burner orifice
- Page 22 – IMPORTANT
- Page 23 – CABINET; Air Passageways; WARNING: Turn off fireplace; SERVICE HINTS; When Gas Pressure Is Too Low; Figure 36 - Pilot Inlet Air Hole
- Page 25 – PARTS LIST; KEY
- Page 26 – SPECIFICATIONS; PARTS UNDER WARRANTY
- Page 27 – ACCESSORIES
- Page 28 – KEEP THIS WARRANTY; Model; WARRANTY INFORMATION; NOT A UPC
Save this manual for future reference.
VENT-FREE NATURAL GAS
COMPACT CLASSIC HEARTH
®
FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
®
Shown with Optional
Cabinet Mantel/Hearth
Base Accessory
VMH10TNB
10,000 Btu/Hr with
Thermostat
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper instal-
lation, adjustment, alteration,
service, or maintenance can
cause injury or property dam-
age. Refer to this manual for
correct installation and op-
erational procedures. For as-
sistance or additional infor-
mation consult a qualified in-
staller, service agency, or the
gas supplier.
W A R N I N G : T h i s i s a n
unvented gas-fired heater. It
uses air (oxygen) from the
room in which it is installed.
Provisions for adequate com-
bustion and ventilation air
must be provided. Refer to
Air for Combustion and Ven-
tilation section on page 5 of
this manual.
This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 107031 VENT-FREE NATURAL GAS COMPACT FIREPLACE VMH10TNB ® SAFETYINFORMATION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble theflu, with headaches, dizziness, or nausea. Ifyou have these signs, the fireplace may notbe working properly. Get fresh air at once!Have firepl...
3 107031 OWNER’S MANUAL PRODUCTIDENTIFICATION LOCAL CODES Install and use fireplace with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode ANS Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 143...
4 107031 VENT-FREE NATURAL GAS COMPACT FIREPLACE VMH10TNB ® ASSEMBLY ASSEMBLING FIREPLACE Tools Required: • Phillips screwdriver • 5/16" hex wrench • slotted screwdriver • scissors Installing Log 1. Lift screen up and pull out to remove. 2. Cut two plastic straps to remove the logfrom the firebo...