Stanley 2005 Series - Manual
Stanley 2005 Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – , turn the keypad back counterclockwise to stop.; perating; Multi-User Electronic Safe Lock
- Page 3 – This lock is capable of using a; time delay override code; if it; time delay; can be used to open the lock without waiting for; TDO code; only works when your lock uses a time delay.
- Page 5 – Time delay
- Page 7 – user code; master code; anagIng; off; anagIng
- Page 8 – oW
- Page 9 – Figure 1; attery
- Page 10 – Figure 4; —Carefully slide the battery behind the keypad, into the; Figure 5
- Page 12 – WARRANTY
The S&G
©
X
03
D-Drive
™
lock combines ease of operation with
security and flexibility. Its advanced electronic circuit design
makes it easy to open and easy to change codes. Follow these
instructions carefully to get the best possible use from your lock.
I
ntroductIon
• This S&G
©
X
03
D-Drive
™
lock is shipped from the factory in
multi-user mode with a
factory master code
of 1 2 3 4 5 6
#. This code can be used to open the lock and set or change
codes. You should set the lock to your own, unique
master
code
.
• Your lock can be programmed with a
management reset code
that can be used to regain control of the lock in the event the
master code
is lost. The
management reset code
must be
programmed into the lock before the
master code
is changed
for the first time.
• At your discretion, the lock can be set to accept a
supervisor
code
, up to seven different
user codes,
and a
time delay
override code
. The
master code
holder and the
supervisor
code
holder (if a
supervisor code
is set) are responsible
for maintaining the number of active users programmed into
each lock. The
master code
holder and the
supervisor code
holder can create and delete user codes.
• The
master code
is designated as code #0. The
supervisor
code
(if set) is designated as code #1. The
user codes
(if
set) are designated by user position numbers 2, 3, 4, 5, 6, 7,
and 8. The
time delay override code
(if set) is designated as
code #9.
• Each time a button is pressed, the lock acknowledges it
by sounding a “beep,” and the LED on the keypad will light
momentarily as the “beep” sounds. If it does not, check your
battery (or batteries) to make sure it is fresh and connected
properly, then try again.
• All codes must contain six digits or six letters. Any digit or
letter can be used as many times as you wish. For instance,
the following codes (while not recommended) will operate the
lock: 5 5 5 5 5 5 # OR J J J J J J #
• All codes end with #. This signals the
lock that you have finished entering all
digits of the code.
• If you pause more than 10 seconds
between button presses when entering
a code, the lock will assume you do not
want to continue, and it will reset itself
to the original code. To open the lock,
begin the code entry sequence once again from the first step.
• If you realize you have pressed an incorrect button when
entering a code, press
✽
or simply pause ten seconds or more,
then begin entering your code again.
• If five incorrect codes are entered in a row, the S&G
©
X
03
D-
Drive
™
lock will shut down for a period of ten minutes. This
is a security feature. Entering a code during this period will
result in two long error tones (braps). Pressing any buttons
during the lockout period will not affect the penalty timer.
After ten minutes, the lock should operate normally.
The lock can also go into the lockout period during
programming if it interprets an incorrect programming
sequence as five or more consecutive incorrect code entries.
If the lock emits two long error tones (braps) during repeated
programming attempts, it is in lockout mode. Wait ten
minutes, then try again.
• For UL installations, the maximum number of working codes
allowed is one.
• Personal data which can be directly related to a code holder,
such as a birthdate, should not be used in making up a lock
code. Avoid codes which can be easily guessed.
• After the lock is changed to a new code, the lock function
must checked by locking and unlocking it several times with
the container door open. Make sure it functions correctly
before closing the door.
Note: This lock has been Listed by Underwriters Laboratories for use with the following
S&G keypad(s): 6130-2XX and 6130-3XX
© Copyright 2006, Sargent & Greenleaf
Document 630-735
Revised 7/25/06
Sargent & Greenleaf, Inc.
A Wholly Owned Subsidiary of Stanley Security Solutions, Inc.
PO Box 930, Nicholasville, Kentucky 40356 USA
Phone (859) 885-9411
Phone (800) 826-7652
FAX (859) 887-2057
FAX (800) 634-4843
Sargent & Greenleaf S.A.
9, chemin du Croset
1024 Ecublens, Switzerland
Phone +41-21 694 34 00
FAX +41-21 694 34 09
O
perating
i
nstructiOns
S&G
®
Z
03
D-Drive
™
Multi-User Electronic Safe Lock
2005 Series
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
© Copyright 2006, Sargent & Greenleaf Page 2 t o o pen the L ock Make sure the keypad is turned counterclockwise to stop. Press the code digits or letters in order, followed by # . Then, within six seconds, turn the keypad clockwise about 70 degrees, until it comes to a positive stop. Do not put...
o penIng the L ock ➥ W Ith n o t Ime d eLay A valid code is needed to open the lock. This is how to open the lock with the original factory master code of 1 2 3 4 5 6. Make sure the keypad is turned counterclockwise to stop.Enter 1 2 3 4 5 6 # Then, within six seconds, turn the keypad clockwise abou...
➥ d eLetIng an e xIstIng c ode The holder of the master code (position 0) can delete any other code. The master code cannot be deleted under any circumstances. The holder of the supervisor code (position 1) can delete user codes . The supervisor code cannot be used to delete the master code or itsel...