Remington REM-80TBOA-KFA-B - User Manual

Remington REM-80TBOA-KFA-B

Remington REM-80TBOA-KFA-B Heater – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – © 2021 Pinnacle Climate Technologies, Inc.; THE INSTALLATION OF THE EQUIPMENT SHALL BE IN ACCORDANCE WITH THE; tance away from the heater as recommended by these instructions.; DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND; WARNING; SAFETY INFORMATION
  • Page 3 – Minimum Clearance From Combustibles; Headache
  • Page 4 – SPECIFICATIONS; FEATURES; - Remove the heater and all packaging materials; Note: Save the box and packaging materials
  • Page 5 – - Risk of indoor air pollution and Carbon Monoxide; OPERATION; CAUTION
  • Page 6 – Restarting the Heater:
  • Page 7 – BATTERY OPERATION INSTRUCTIONS
  • Page 8 – MAINTENANCE
  • Page 10 – WIRING DIAGRAMS; Wiring Diagram / Diagrama eléctrico; GN; Sensor
  • Page 11 – TROUBLESHOOTING GUIDE; Problem
  • Page 12 – EXPLODED VIEW
  • Page 13 – PARTS LIST
  • Page 14 – LIMITED WARRANTY
  • Page 15 – CONSOMMATEUR : LIRE ET CONSERVER CES INSTRUCTIONS IMPORTANTES; CET APPAREIL DE; Cet aérotherme portable non raccordé utilise l’air (oxygène); DANGER; Guide d’utilisation et mode d’emploi; AÉROTHERME
  • Page 16 – Guide d’utilisation de l’aérotherme au kérosène; CONSIGNES DE SÉCURITÉ; AVERTISSEMENT
  • Page 18 – FICHE TECHNIQUE; CARACTÉRISTIQUES; - Retirer l’appareil et tout le matériel d’emballage; d’emballage pour y ranger ultérieurement
  • Page 19 – - Risque de pollution de l’air intérieur et; MODE D’EMPLOI
  • Page 20 – Le circuit de protection de batterie de; Redémarrage de l’aérotherme :; ATTENTION; batterie branchée; LORSQU’ELLE N’EST PAS UTILISÉE
  • Page 21 – DIRECTIVES POUR UNE UTILISATION AVEC UNE BATTERIE
  • Page 22 – ENTRETIEN; PALES DE VENTILATEUR :
  • Page 24 – SCHÉMAS DE CÂBLAGE
  • Page 25 – GUIDE DE DÉPANNAGE; Anomalie
  • Page 26 – VUE ÉCLATÉE
  • Page 27 – LISTE DES PIÈCES
  • Page 28 – GARANTIE LIMITÉE
Loading the manual

MODEL NUMBERS:

REM-80TBOA-KFA-B

CONSUMER: READ AND SAVE THESE IMPORTANT INSTRUCTIONS

GENERAL HAZARD WARNING: READ AND UNDERSTAND
ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER.
Be sure

to comply with the instructions and warnings provided with this heater. Failure to comply

can result in fire or explosion that can cause property loss, bodily injury, or loss of life. Only

persons who can follow and understand these instructions should operate or service this

heater. If you need heater info; such as an operating manual, labels, etcetera, contact Pinnacle

Climate Technologies at 800-641-6996.

DANGER

NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED

SPACES WITHOUT ADEQUATE VENTILATION. THIS HEATER

IS NOT FOR USE WHERE EXPOSED TO THE WEATHER, AND

INDOOR USE ONLY IN WELL-VENTILATED AREAS. INDOOR USE PERMITTED ONLY FOR:

THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES
UNDER CONSTRUCTION, ALTERATION OR REPAIR.

This is an unvented portable heater

that uses air (Oxygen) from within the area in which it is used. Failure to provide adequate

combustion and ventilation air will result in asphyxiation, carbon monoxide poisoning, bodily

injury or death. Refer to “Ventilation” on Page 5.

FACTORY ID: 500

DANGER

Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996

Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: [email protected]

© 2021 Pinnacle Climate Technologies, Inc.

RBKB-40

9

User’s Manual & Operating Instructions

BATTERY OPERATED

KEROSENE FORCED

AIR HEATER

Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. For Example:
150812779. Have your Serial Number ready before calling customer service at 800-641-6996.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - © 2021 Pinnacle Climate Technologies, Inc.; THE INSTALLATION OF THE EQUIPMENT SHALL BE IN ACCORDANCE WITH THE; tance away from the heater as recommended by these instructions.; DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND; WARNING; SAFETY INFORMATION

2 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual MASSACHUSETTS RESIDENTS: Massachusetts state law prohibits the use of this heater in any building which is used in whole or in part f...

Page 3 - Minimum Clearance From Combustibles; Headache

3 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual SAFETY INFORMATION (CONT.) ALWAYS use only the electrical power (voltage and frequency) specified on the model plate of the heater.AL...

Page 4 - SPECIFICATIONS; FEATURES; - Remove the heater and all packaging materials; Note: Save the box and packaging materials

4 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual SPECIFICATIONS Model # REM-80TBOA-KFA-B Rating: Btu/Hr / kW 80,000 / 23.4 Fuel Consumption: Gal/Hr / L/Hr 0.63 / 2.38 Fuel Tank Capac...

Other Remington Heaters Models

All Remington Heaters