Page 2 - NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR; TABLE OF CONTENTS; DANGER; for outdoor use, and indoor use only in well-ventilated areas.; DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND THOROUGHLY; WARNING
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 2 Safety Information.......................................................2-5 Unpacking...................................................
Page 3 - Minimum Clearance From Combustibles
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 3 The products described in this manual are propane direct-fired, forced air heaters. Propane forced air heaters are primarily intended ...
Page 4 - CO
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 4 – Do not use this heater for heating human living quarters – Use of direct-fired heaters in the construction environment can result in...
Page 5 - Manifold, Minimum, and Maximum Inlet Pressure; RISK OF ELECTRIC SHOCK!; Figure 1; UNPACKING; CAUTION
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 5 ALWAYS install the heater so that it is not directly exposed to water spray, rain, dripping water, or wind. – Use heater in accordance...
Page 6 - SPECIFICATIONS; FEATURES
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 6 SPECIFICATIONS Model # 40-GFA 60V-GFA 125V-GFA 150V-GFA BTU 40,000 40 / 50 / 60,000 95 / 110 / 125,000 120 / 135 / 150,000 Fuel Consum...
Page 7 - OPERATION; The Propane (LP) cylinder must also be equipped with; Propane is safe to
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 7 OPERATION Propane Supply / Information:Propane (LP)This heater is not supplied with a propane cylinder. Use only an approved propane c...
Page 8 - Connecting the LP Cylinder
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 8 OPERATION (CONT.) Pre-Lighting Instructions: Connecting the LP Cylinder ALL NEW LP CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING. ...
Page 9 - initiating service, cleaning with recommended cleaning; VENTILATION; Risk of indoor air pollution and Carbon Monoxide; output. Provide a larger opening if more heaters; Minimum Ventilation Opening Needed
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 9 OPERATION (CONT.) Lighting Instructions: Starting the Heater (Ignition)1. Connect the heater to a three prong (grounded) power source....
Page 10 - WIRING/SCHEMATIC DIAGRAMS
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 10 WIRING/SCHEMATIC DIAGRAMS THERMAL SWITCH BLACK POWER CORD EARTH (SHELL) CONDENSER MOTOR THERMOC OUPLE CONTROL V AL VE YELL O W YELLOW...
Page 11 - Problem; TROUBLESHOOTING GUIDE; ALWAYS be sure to follow proper maintenance proce-
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 11 Problem Possible Cause(s) Solution Fan does not turn when electricity is connected. 1. No electric power to heater. 2. Blades of fan ...
Page 12 - EXPLODED VIEW; Description; PARTS LIST
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 12 3 4 8 9 10 11 12 15 18 17 14 2 20 1 19 5 7 6 13 16 EXPLODED VIEW Item # Description 40-GFA 60V-GFA 125V-GFA 150V-GFA 1 Height Control...
Page 13 - LIMITED WARRANTY; Locating Your Serial Number:
© 2021 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 13 LIMITED WARRANTY Pinnacle Climate Technologies, Inc. warrants this heater to the original retail purchaser only, to be free from defe...
Page 14 - AVERTISSEMENT GÉNÉRAL DE DANGER :; AVERTISSEMENT; CHAUFFERETTE À AIR FORCÉ AU PROPANE; Repérage du numéro de série :
NUMÉROS DE MODÈLES : REM-40-GFA-B / REM-60V-GFA-B / REM-125V-GFA-B / REM-150V-GFA-B NOTE AU CLIENT : LIRE ET CONSERVER CES INSTRUCTIONS POUR POUVOIR S’Y REPORTER ULTÉRIEUREMENT C E R T I F I E D AVERTISSEMENT GÉNÉRAL DE DANGER : LE NON-RESPECT DES MISES EN GARDE ET DES INSTRUCTIONS FOURNIES AVEC CET...
Page 15 - NE JAMAIS LAISSER UNE CHAUFFERETTE SANS; TABLE DES MATIÈRES; ou dans un espace clos qui n’est pas ventilé adéquatement. Ne jamais; NE PAS UTILISER CETTE CHAUFFERETTE AVANT D’AVOIR LU ET; NE PAS UTILISER DANS LES HABITATIONS OU VÉHICULES RÉCRÉATIFS.
© 2021, Pinnacle Climate Technologies, Inc. Manuel d’instructions de la chaufferette à air forcé au propane NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION 2 Consignes de sécurité ................................................
Page 16 - Dégagement minimal par rapport aux combustibles
© 2021, Pinnacle Climate Technologies, Inc. Manuel d’instructions de la chaufferette à air forcé au propane NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION 3 Les produits décrits dans ce manuel sont des chaufferettes à feu di...
Page 18 - minimum et maximum; DÉBALLAGE; RISQUE DE DÉCHARGE
© 2021, Pinnacle Climate Technologies, Inc. Manuel d’instructions de la chaufferette à air forcé au propane NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION 5 TOUJOURS débrancher la chaufferette lorsqu’elle n’est pas utilisée....
Page 19 - SPÉCIFICATIONS; Modèles n°; CARACTÉRISTIQUES
© 2021, Pinnacle Climate Technologies, Inc. Manuel d’instructions de la chaufferette à air forcé au propane NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION 6 SPÉCIFICATIONS Modèles n° 40-GFA 60V-GFA 125V-GFA 150V-GFA BTU 40 0...
Page 20 - MODE D’EMPLOI
© 2021, Pinnacle Climate Technologies, Inc. Manuel d’instructions de la chaufferette à air forcé au propane NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION 7 MODE D’EMPLOI Informations sur le propane :Propane (GPL)Cette chauf...
Page 22 - Vérification de l’allumage de la chaufferette; frais d’au moins 2 800 cm2 pour chaque sortie de; Ouverture minimum requise pour la ventilation
© 2021, Pinnacle Climate Technologies, Inc. Manuel d’instructions de la chaufferette à air forcé au propane NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION 9 MODE D’EMPLOI (SUITE) Instructions d’allumage : Démarrage de la cha...
Page 23 - SCHÉMAS DE CÂBLAGE; Wiring Diagrams / Schéma de câblage
© 2021, Pinnacle Climate Technologies, Inc. Manuel d’instructions de la chaufferette à air forcé au propane NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION 10 SCHÉMAS DE CÂBLAGE THERMORUPTEUR NOIR CORDON ÉLECTRIQUE TERRE (BOÎ...
Page 24 - Problème; GUIDE DE DÉPANNAGE
© 2021, Pinnacle Climate Technologies, Inc. Manuel d’instructions de la chaufferette à air forcé au propane NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION 11 Problème Causes possibles Solution Le ventilateur ne tourne pas lo...
Page 25 - VUE ÉCLATÉE; de; LISTE DES PIÈCES
© 2021, Pinnacle Climate Technologies, Inc. Manuel d’instructions de la chaufferette à air forcé au propane NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION 12 3 4 8 9 10 11 12 15 18 17 14 2 20 1 19 5 7 6 13 16 VUE ÉCLATÉE N o...
Page 26 - GARANTIE LIMITÉE
© 2021, Pinnacle Climate Technologies, Inc. Manuel d’instructions de la chaufferette à air forcé au propane NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION 13 GARANTIE LIMITÉE Pinnacle Climate Technologies, Inc. garantit à l’...