Switch Settings Manual

C2447M (2/02)

®

Table A.

Switch Settings for SW3
Baud Rate Selection Switch

Table B.

Switch Settings for SW1
P-Type Control

NOTE:

For Coaxitron

controls, SW1 is not
used; set all switches
OFF. For D-type control
systems, refer to Table C.

Tabla A.

Posiciones del
conmutador SW3
Conmutador de selección
de velocidad en baudios

Tabela A.

Configurações de Chave
para SW3
Chave de seleção de
taxa de bauds

Tabla B.

Posiciones del
conmutador SW1
Control tipo P

NOTA:

En los controles

Coaxitron, SW1 no se usa.
Coloque todos los
conmutadores en posición
de desactivación. Para
controles tipo D, consulte
la Tabla C.

Tabela B.

Configurações de Chave
para SW1
Controle tipo P

NOTA:

Para controles

Coaxitron, SW1 não é
usada; configure todas as
chaves para OFF
(desligado). Para
sistemas de controle tipo
D, consulte a tabela C.

Tabelle A.

Schaltereinstellungen für
SW3
Baud-Raten-
Auswahlschalter

Tableau A.

Configuration du

commutateur SW3
Commutateur de sélection
de la vitesse de transfert

Tabella A.

Impostazioni
dell’interruttore per SW3
Interruttore di selezione
della velocità di
trasmissione

Tabelle B.

Schaltereinstellungen für
SW1
Steuerung Typ P

HINWEIS:

Für

Steuerungen des Typs
Coaxitron controls wird
SW1 nicht verwendet;
stellen Sie alle Schalter
auf OFF. Zu den
Steuerungssystemen Typ
D siehe Tabelle C.

Tableau B.

Configuration du
commutateur SW1
Protocole de contrôle P

REMARQUE:

Pour le

protocole de contrôle
Coaxitron, SW1 n’est pas
utilisé; mettre tous les
commutateurs sur OFF.
Pour les systèmes avec
protocole de contrôle D,
reportez-vous au tableau C.

Tabella B.

Impostazioni
dell’interruttore SW1
Controllo tipo P

NOTA:

Per i controlli

Coaxitron non viene usato
l’interruttore SW1;
impostare tutti gli
interruttori su OFF. Per i
sistemi di controllo tipo D,
consultare la Tabella C.

SPECTRA

SWITCH SETTING

ADDRESS

SW1-1

SW1-2

SW1-3

SW1-4

SW1-5

1

OFF

OFF

OFF

OFF

OFF

2

ON

OFF

OFF

OFF

OFF

3

OFF

ON

OFF

OFF

OFF

4

ON

ON

OFF

OFF

OFF

5

OFF

OFF

ON

OFF

OFF

6

ON

OFF

ON

OFF

OFF

7

OFF

ON

ON

OFF

OFF

8

ON

ON

ON

OFF

OFF

9

OFF

OFF

OFF

ON

OFF

10

ON

OFF

OFF

ON

OFF

11

OFF

ON

OFF

ON

OFF

12

ON

ON

OFF

ON

OFF

13

OFF

OFF

ON

ON

OFF

14

ON

OFF

ON

ON

OFF

15

OFF

ON

ON

ON

OFF

16

ON

ON

ON

ON

OFF

SPECTRA

SWITCH SETTING

ADDRESS

SW1-1

SW1-2

SW1-3

SW1-4

SW1-5

17

OFF

OFF

OFF

OFF

ON

18

ON

OFF

OFF

OFF

ON

19

OFF

ON

OFF

OFF

ON

20

ON

ON

OFF

OFF

ON

21

OFF

OFF

ON

OFF

ON

22

ON

OFF

ON

OFF

ON

23

OFF

ON

ON

OFF

ON

24

ON

ON

ON

OFF

ON

25

OFF

OFF

OFF

ON

ON

26

ON

OFF

OFF

ON

ON

27

OFF

ON

OFF

ON

ON

28

ON

ON

OFF

ON

ON

29

OFF

OFF

ON

ON

ON

30

ON

OFF

ON

ON

ON

31

OFF

ON

ON

ON

ON

32

ON

ON

ON

ON

ON

Special Systems

Switch Number

1

2

3

4

5

6

7

8

AD-32 Preset System

On

CM9502 Setting

On

P Protocol Baud Rate

Switch Number

1

2

3

4

5

6

7

8

2400 Baud

Off

Off

Off

4800 Baud

On

Off

Off

9600 Baud

Off

On

Off