Table of Contents:

  • Page 2 – Check coolant; INSTALLATION
  • Page 3 – SPECIFICATIONS; MECHANICAL; Figure 2. HT10 Series Dimension Drawing
  • Page 4 – WARRANTY AND RETURN INFORMATION; REVISION HISTORY; Date; Updated manual to new format. Created separate manual for WCAL.
Loading the manual

C421M-D (2/00)
HT10 Series
Liquid-Cooled Enclosure

®

IMPORTANT SAFEGUARDS AND WARNINGS

Prior to installation and use of this product, the following WARNINGS should be observed.

1.

Installation and servicing should only be done by qualified service personnel and conform
to all local codes.

2.

Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclo-
sure, it is designed for indoor use only and it must not be installed where exposed to rain
and moisture.

3.

Only use replacement parts recommended by Pelco.

4.

After replacement/repair of this unit’s electrical components, conduct a resistance mea-
surement between line and exposed parts to verify the exposed parts have not been con-
nected to line circuitry.

5.

The installation method and materials should be capable of supporting four times the
weight of the enclosure, pan/tilt, camera and lens combination.

6.

Use or mount this enclosure so that it is positioned not less than 91 degrees and not
more than 180 degrees when considering 12 o’clock to be 0 degrees and 6 o’clock to be
180 degrees.

7.

Only Nema 3R liquid tight conduit should be used in all outdoor applications.

The product and/or manual may bear the following marks:

This symbol indicates that danger-
ous voltage constituting a risk of
electric shock is present within
this unit.

This symbol indicates that there
are important operating and main-
tenance instructions in the litera-
ture accompanying this unit.

Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.

DESCRIPTION

The products in the HT10 Series are liquid-cooled enclosures designed for high temperature
applications.

The stainless steel enclosure features two separate double-walled cooling jackets that protect
the camera and lens and other sensing devices housed within the unit.

Models

HT10V

High temperature enclosure with Vycor

®

window; window suitable in

temperatures up to 2500

°

F (1371

°

C)

HT10V/RC

Same as the HT10V except Vycor window has an infrared reflective coating
for environments where high levels of radiant heat are encountered; window
suitable in temperatures up to 1832

°

F (1000

°

C)

C A U T I O N :

RISK OF ELECTRIC SHOCK.

DO NOT OPEN.

300 W. Pontiac Way,
Clovis, CA 93612-5699
USA

In North America & Canada:
Tel (800) 289-9100
FAX (800) 289-9150
DataFAX (800) 289-9108

International Customers:
Tel +1 (559) 292-1981
FAX +1 (559) 348-1120
DataFAX +1 (559) 292-0435

Pelco Online
http://www.pelco.com

L I S T E D

UL

®

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Check coolant; INSTALLATION

IMPORTANT: Check coolant flow rate periodically to ensurethat sediment or deposits arenot restricting flow. This will pre-vent heat from building up in theenclosure, or steam from devel-oping in the water jacket. *RESERVOIR *COOLING TANK *SHUT OFFVALVES COOLINGJACKET COOLINGJACKET *LOCATION OF EQUIP...

Page 3 - SPECIFICATIONS; MECHANICAL; Figure 2. HT10 Series Dimension Drawing

SPECIFICATIONS MECHANICAL Cooling Pipe Connections: Standard 3/8-inch NPT pipe fittings Suggested OperatingPressure: 35 psi, approximately 2.3 gallons/minute Cooling Jacket Volume: Approximately 3 gallons GENERAL Construction: Type 304 stainless steel Finish: Silver-gray paint Viewing W indow HT10V:...

Page 4 - WARRANTY AND RETURN INFORMATION; REVISION HISTORY; Date; Updated manual to new format. Created separate manual for WCAL.

® Pelco, the Pelco logo, Spectra, Genex, Legacy, and Intercept are registered trademarks of Pelco. ™ Esprit is a trademark of Pelco. ® Vycor is a registered trademark of Corning Glass Works. © Copyright 1999, Pelco. All rights reserved. WARRANTY Pelco will repair or replace, without charge, any merc...

Other Pelco Models

All Pelco Other