Pelco HK700 - Manual
Pelco HK700 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Blower Kit; Power Requirements and Recommended Cable Sizes (Continued)
- Page 3 – Blower Kit Installation; Heater Kit; Blower and Heater Kits (Dual; Blower and Heater Kits Wiring Diagram (All Models); Blower Kit Wiring Diagram
- Page 4 – Endura and ExSite are trademarks of Pelco.; REVISION HISTORY; Date; Blower and Heater Kits (Dual Installation); - Remove the PC board from the heater assembly. Attach; SERVICE MANUAL; PRODUCT WARRANTY AND RETURN INFORMATION; WARRANTY
C2412M (11/99)
BK700 Series Blower Kit
HK700 Series Heater Kit
®
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1.
Installation and servicing should only be done by qualified service personnel and conform
to all local codes.
2.
Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P
enclosure, it is designed for indoor use only and it must not be installed where exposed to
rain and moisture.
3.
Only use replacement par ts recommended by Pelco.
4.
After replacement/repair of this unit’s electrical components, conduct a resistance
measurement between line and exposed par ts to verify the exposed par ts have not
been connected to line circuitry.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
3500 Pelco Way
Clovis, CA 93612-5699
USA
In North America & Canada:
Tel (800) 289-9100
FAX (800) 289-9150
International Customers:
Tel +1 (559) 292-1981
FAX +1 (559) 348-1120
www.pelco.com
MODELS
Blower Kits
BK700
For use with E706 or E708 Series Enclosure, 120 VAC, 60 Hz, 4 watts,
10 cfm internal air circulation
BK700/220
Same as BK700 except 230 VAC, 50 Hz, 9 watts, 8 cfm internal air
circulation
BK700/24
Same as BK700 except 24 VAC, 3 watts, 19 cfm of internal air circulation
Heater Kits
HK706-1
Thermostatically controlled, 120 VAC, 80 watts, for E706 Series Enclosure
only. Activates ON at 40
°
F (4
°
C) and OFF at 60
°
F (16
°
C)
HK706-2
Same as HK706-1 except 24 VAC
HK706-3
Same as HK706-1 except 230 VAC
HK708/10-1
Thermostatically controlled, 120 VAC, 107 watts, for E708 Series
Enclosure only. Activates ON at 40
°
F (4
°
C) and OFF at 60
°
F (16
°
C)
HK708/10-2
Same as HK708/10-1 except 24 VAC, 66 watts
HK708/10-3
Same as HK708/10-1 except 230 VAC, 84 watts
INSTALLATION
CAUTION:
When a single power source is used for both the camera and
accessories, the camera power consumption must be taken into consideration
when determining the wire gauge. However, the following char t does not
include camera power because of the many variations.
Model Number
Input Voltage
Power Consumption
Cable Size
Cable Distance
BK700
120 VAC
4 watts
22 AWG
10,651 feet
(3,246 m)
20 AWG
17,143 feet
(5,225 m)
18 AWG
27,108 feet
(8,262 m)
16 AWG
43,062 feet
(13,125 m)
BK700/24
24 VAC
3 watts
20 AWG
914 feet
(279 m)
18 AWG
1,446 feet
(441 m)
16 AWG
2,297 feet
(700 m)
14 AWG
3,650 feet
(1,113 m)
Table A.
Power Requirements and Recommended Cable Sizes
Continued on next page
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Model Number Imput Voltage Power Consumption Cable Size Cable Distance BK700/200 230 VAC 9 watts 20 AWG 25,609 feet (7,805 m) 18 AWG 40,495 feet (12,342 m) 16 AWG 64,328 feet (19,606 m) 14 AWG 102,239 feet (31,161 m) HK706-1 120 VAC 80 watts 20 AWG 533 feet (162 m) 18 AWG 857 feet (261 m) 16 AWG 1,3...
E700 SLED MOUNTING BRACKET BLOWER ASSEMBLY PC BOARD (230 VAC ONLY) Figure 1. Blower Kit Installation HEATER BRACKET ASSEMBLY REAR PLATE PC BOARD ASSEMBLY CAMERA SLED Heater Kit If you are installing the heater kit in conjunc-tion with a blower kit, skip this section andrefer to Blower and Heater Kit...
Pelco, the Pelco logo, Spectra, Genex, Legacy, Esprit, and Camclosure are registered trademarks of Pelco. © Copyright 1999, Pelco. Endura and ExSite are trademarks of Pelco. All rights reserved. REVISION HISTORY Manual # Date Comments C2412M 11/99 Original version. Blower and Heater Kits (Dual Insta...