HB6000, HB6000/220, and
HB6024
Heater/Blower Kits
Installation/Operation
Manual C496M (12/90)
1.0 WARNINGS
Prior to installation and use of this product, the following
WARNINGS should be observed.
1.
Installation and servicing should only be done by
Qualified Service Personnel and conform to all
Local codes.
2.
Installation should be in accordance with all
applicable local and national electric codes, utilizing
approve materials only.
3.
Only use replacement parts recommended by Pelco.
Please thoroughly familiarize yourself with the informa-
tion in this manual prior to installation and operation.
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com
(800) 289-9100 or (1-559) 292-1981 • FAX (800) 289-9150 or (1-559) 292-3827
International customers call (1-559) 292-1981 or FAX (1-559) 348-1120
2.0 SCOPE
The information within this manual covers the installa-
tion of the HB6000, HB6000/220, and HB6024 Heater/
Blower Kits.
3.0 DESCRIPTION
The HB6000 (120 VAC), HB6000/220 (230 VAC), and
the HB6024 (24 VAC) are field installed heater/blower
kits for the HS1000 and HS6000 series high security
enclosures. These heater/blower kits will help stabilize
the internal enclosure temperatures when the enclosures
are subjected to more extreme conditions.
The heaters provide 80 watts of heat thermostatically
controlled to turn ON at 40
°
F (4.44
°
C) and OFF at 60
°
F
(15.56
°
C).
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Pelco Manual C496M (12/90) 3.1 MODELS HB6000 120 VAC thermostatically controlledheater and blower. Heater provides80 watts of heat and activates ON at40 ° F (4.44 ° C) and OFF at 60 ° F (15.56 ° C). Blower provides internal air circulation (12 cfm at 4 watts) andactivates ON at 110 ° F (43.33 ° C)...
Pelco Manual C496M (12/90) 3 3.4 POWER REQUIREMENTS The blower and heater require a 24 VAC/120 VAC/230VAC, 50/60 Hz single phase power source. They usethe following wattage when in operation. Blower: 4.5 watts Heater: 80 watts 4.0 INSTALLATION To install the HB6000, HB6000/220, and HB6024 per-form t...
4 Pelco Manual C496M (12/90) 4.3 HEATER/BLOWER WIRING The blower is factory wired to the PCB assembly. Connect the heaters to the PCB assembly as shown inthe respective wiring diagrams (refer to Figure 2, Fig-ure 3, or Figure 4). Supply AC line voltage (230 VAC, 120 VAC, or 24 VAC)as shown. 4.4 ELEC...