Page 3 - List of Tables
C2624M (6/07) 3 List of Tables A TX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 B FX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 C Troubleshooting w...
Page 4 - Important Safety Instructions
4 C2624M (6/07) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manu...
Page 5 - RISK OF ELECTRIC SHOCK.
C2624M (6/07) 5 The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying...
Page 6 - Regulatory Notices; RADIO AND TELEVISION INTERFERENCE
6 C2624M (6/07) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired ...
Page 7 - Product Overview; DESCRIPTION
C2624M (6/07) 7 Product Overview DESCRIPTION The FX82012 unmanaged Ethernet switch provides one 10BASE-T/100BASE-TX port and two 100BASE-FX fiber ports for the transport of bidirectional Ethernet data. Available in multimode and single-mode versions, the fiber ports use wavelength division multiplex...
Page 9 - MODELS; OPTIONAL ACCESSORIES
C2624M (6/07) 9 MODELS The FX82012 module consists of the following series of models: Multimode Models:* FX82012MSTR-2 Unmanaged Ethernet switch, one 10BASE-T/100BASE-TX port, two multimode ST fiber ports, one fiber per port (total of two fibers) FX82012MSCR-2 Unmanaged Ethernet switch, one 10BASE-T...
Page 10 - FRONT PANEL
10 C2624M (6/07) FRONT PANEL Figure 3 illustrates the front panel of the FX82012 module. Figure 3. Front Panel of FX82012 Module For detailed information about the front-panel LEDs, refer to the Troubleshooting section. ì RESET BUTTON (restarts the unit) î FIBER FAILOVER (REDUNDANCY) MODE LED ï 100B...
Page 11 - REAR PANEL
C2624M (6/07) 11 REAR PANEL Figure 4 illustrates the rear panel of the FX82012 module. Figure 4. Rear Panel of FX82012 Module (SC Fiber Connectors Shown) For additional information about rear-panel connections, refer to the Installation section. For detailed information about the RJ-45 LEDs, refer t...
Page 12 - Installation; PACKAGE CONTENTS
12 C2624M (6/07) Installation PACKAGE CONTENTS The following items are supplied: 1 FX82012 module 1 Regulated switching power supply with four plug adapters (North American, Australian, U.K., and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4-40 x 0.250-i...
Page 13 - TX Mode
C2624M (6/07) 13 Using the TX Mode switch, you can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegotiation allows the FX82012 module to automatically negotiate with the device to which the port is connected for data rate and duple...
Page 14 - SETTING FIBER FAILOVER MODE
14 C2624M (6/07) SETTING FIBER FAILOVER MODE NOTE: As a matter of convenience, it is recommended that you set fiber failover (redundancy) mode—if required—before mounting the FX82012 module into a rack or onto a wall. Fiber failover mode is disabled by default. The FX82012 module can operate in fibe...
Page 15 - MOUNTING; MOUNTING THE FX82012 MODULE INTO A RACK
C2624M (6/07) 15 Table B. FX Mode Switch Settings MOUNTING The FX82012 module can be mounted into a rack or can be used as a stand-alone module. As a stand-alone module, the unit can be placed on a desktop or can be mounted to a wall. NOTE: As a matter of convenience, it is recommended that you set ...
Page 16 - MOUNTING THE FX82012 MODULE TO A WALL; Mounting the FX82012 Module Using the Wall Clip
16 C2624M (6/07) MOUNTING THE FX82012 MODULE TO A WALL The FX82012 module can be mounted to a wall in the following ways: • Using the supplied wall clip for attachment of a single module to a wall. For installation instructions, refer to the Mounting the FX82012 Module Using the Wall Clip section. •...
Page 18 - CONNECTIONS
18 C2624M (6/07) CONNECTIONS Connections to the FX82012 module are made on the rear panel of the module (refer to Figure 8). Figure 8. FX82012 Connections (SC Fiber Connectors Shown) As illustrated in Figure 8, FX82012 connections consist of the following: • Power connection – A 12 VDC or 24 VAC pow...
Page 22 - Indicator Color
22 C2624M (6/07) Troubleshooting LED indicators on the front and rear panels of the FX82012 module allow you to monitor operational status: • LED indicators on the front panel allow you to monitor operating power, fiber redundancy mode status, 100BASE-FX port status, and optic signal/laser status. R...
Page 31 - Specifications; PERFORMANCE
C2624M (6/07) 31 Specifications PERFORMANCE Switch Type Unmanaged Layer 2 Switch Method Store and forward Switch Fabric Non-head-of-line blocking Data Rate 10/100 Mbps Compliance IEEE 802.3, 802.3u, 802.3x Interface Auto MDI/MDI-X Operating Mode Half-duplex or full-duplex Address Table Size 1,024 MA...
Page 35 - PRODUCT WARRANTY AND RETURN INFORMATION
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on fiber optic products and TW3...