Page 2 - L I S T E D; UL
DX3000 Series Digital Recorder Installation/ Operation Manual C681M-D (2/02) ® Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • Pelco Online @ www.pelco.com In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150 • DataFAX (800) 289-9108 International Customers: Tel +1(559) 292-1981...
Page 3 - CONTENTS; Section
2 Pelco Manual C681M-D (2/02) CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ................................................................ 5 OVERVIEW ........................................................................................................................ 6 DESCRIPTION ......
Page 5 - LIST OF ILLUSTRATIONS; Figure
4 Pelco Manual C681M-D (2/02) LIST OF ILLUSTRATIONS Figure Page 1 Front Panel Controls, DX3009 Models .............................................................. 7 2 Front Panel Controls, DX3016 Models .............................................................. 7 3 Rear Panel Connectors, DX300...
Page 6 - IMPORTANT SAFEGUARDS AND WARNINGS; The product and/or manual may bear the following marks:
Pelco Manual C681M-D (2/02) 5 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and con-form to all local codes. 2. Unless the unit is specifical...
Page 7 - OVERVIEW; DESCRIPTION; MODEL
6 Pelco Manual C681M-D (2/02) OVERVIEW DESCRIPTION The DX3000 Series Digital Video Recorder (DVR) is a high-quality digital recorder thatcombines the functions of a recorder and multiplexer into one unit. With the number of cameras in systems increasing, the combination of a video recorderwith a mul...
Page 8 - MODELS; Figure 1. Front Panel Controls, DX3009 Models
Pelco Manual C681M-D (2/02) 7 0 3 2 1 4 6 5 CAMERA 9 8 7 REC ARCHIVE SPLIT/SEQUENCE ZOOM STOP WARNING RESET SEARCH COPY SET UP MENU INFO PAUSE REV PLAY PLAY PLAY MODE - + CLEAR/ REW ENTER/ FF TIMER REC POWER MAIN COPY ARCHIVE PLAY DEVICE EJECT SHUTTLE HOLD TIMER REC M-DET PRE ALARM REC ACCESS LOCK 1...
Page 9 - Press this button to begin recording.
8 Pelco Manual C681M-D (2/02) 3. Recording indicators TIMER REC indicator This light illuminates during timer recording and timer recording standby mode.The POWER button does not work when the TIMER REC indicator is lit. To turn on thepower when the TIMER REC indicator is lit in the standby mode, pr...
Page 11 - REAR PANEL CONNECTORS; Figure 3. Rear Panel Connectors, DX3009 Models; This is an RCA input connector for an audio signal.
10 Pelco Manual C681M-D (2/02) CLOCK ADJ REC POWER ON POWER OFF ALARM OUT MODE OUT CALL OUT CALL OUT GND GND DC 5V OUT MAX 30mA 1 MIC IN OUT 2 3 4 5 6 7 8 9 1 RS-232C 2 3 4 1 GND 2 3 4 5 6 7 8 9 CAMERA IN AUDIO CAMERA OUT ALARM IN 5 6 7 8 9 ON OFF SCSI Y/C VIDEO OUT GND GND GND 1 3 5 6 2 4 7 8 9 10 ...
Page 13 - INSTALLATION; Figure 6. Alarm Input and Output Connections
12 Pelco Manual C681M-D (2/02) CLOCK ADJ REC POWER ON POWER OFF ALARM OUT MODE OUT CALL OUT CALL OUT GND DC 5V OUT MAX 30mA 1 MIC IN OUT 2 3 4 5 6 7 8 9 1 RS-232C 2 3 4 1 2 3 4 5 6 7 8 9 CAMERA IN AUDIO CAMERA OUT ALARM IN 5 6 7 8 RESET 9 ON OFF SCSI SCSI TERMINATION Y/C OUT VIDEO GND GND GND GND GN...
Page 14 - Figure 7. Schematics for Alarm Input and Output Terminals
Pelco Manual C681M-D (2/02) 13 <Interface circuit inside the unit> 5V 5V 10k Ω 22k Ω Inputterminal 0.047 µ F GND POWER ON/POWER OFF/ALARM IN/REC/CLOCK ADJInput terminal • Input Circuit <Interface circuit inside the unit> Output terminal GND terminal ALARM OUT/MODE OUT Output terminal • O...
Page 15 - Figure 10. Schematics for Input and Output Terminals; SERIES RECORDING; Figure 11. Connecting Recorders in Series
14 Pelco Manual C681M-D (2/02) REC ALARM-OUT POWER OFF POWER ON MODE-OUT CALL OUT GND CALL OUT DC 5V OUT MAX 30mA CLOCK ADJUST REC POWER ON POWER OFF ALARM OUT MODE OUT CALL OUT CALL OUT GND First Unit Second Unit GND GND GND GND GND <Interface circuit inside the unit> 5V 5V 10k Ω 22k Ω Inputt...
Page 17 - information about turning on the recorder.; ADDING OR REMOVING A COPY OR ARCHIVE DEVICE; Connect or disconnect the copy or archive device.; All data will be lost on the current drive(s) after you install an; Make sure that the connected device(s) is recognized correctly.
16 Pelco Manual C681M-D (2/02) <DEVICE CHECK> SCSI ID0:HDD (30GB) ID1:HDD ( 9GB) ID2:NONE ID3:NONE ID4:NONE ID5:NONE PWR-OFF INITIALIZE BOOT UP DELAY 00 ID4:RDD ID5:DDS PWR-OFF BOOT UP DELAY 00 6. Connect the power cord to the recorder, and then plug the power cord into a wallsocket. 7. Turn o...
Page 18 - CONFIRMING THAT A DEVICE IS CONNECTED; When the boot-up delay is set and a timer recording is performed, the
Pelco Manual C681M-D (2/02) 17 <DEVICE CHECK> SCSI ID0:HDD (30GB) ID1:HDD ( 9GB) ID2:NONE ID3:NONE ID4:NONE ID5:NONE INITIALIZE ALL HDD BOOT UP DELAY 00 ID5:RDD PWR-OFF CONFIG. BOOT UP DELAY 00 REMOVING A HARD DRIVE(S) This section applies only to devices removed from ID1-ID3. 1. Turn off powe...
Page 19 - PROGRAMMING; SET UP
18 Pelco Manual C681M-D (2/02) PROGRAMMING Figure 13. Menu Tree, DX3009 Models <MENU SETTING> TIME DATE DISPLAY MPX DISPLAY TIMER PROGRAM NORMAL REC SETTING A-REC/M-DET SETTING DATA CLEAR SELECTION COMMUNICATION SETTING <TIME DATE DISPLAY> DISPLAY MODE 1 CHARACTER SIZE SMALL CLOCK LOCATI...
Page 23 - MAXIMUM RECORDING FIELDS; If the PRE A-REC field in this menu has been set to SHORT, MEDIUM,
22 Pelco Manual C681M-D (2/02) ALARMS IMAGE QUALITY Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. Turn the JOG dial to move the cursor to A-REC/M-DET SETTING, and then turn theSHUTTLE ring to the right. The A-Rec/M-Det Setting menu...
Page 24 - DEFINE GROUP SETTING; Skip steps 1 and 2 if they have already been done.; Turning the JOG dial switches the priority options as follows:; When the AUDIO RECORDING setting in the Initial Set Up menu is ON,
Pelco Manual C681M-D (2/02) 23 DEFINE GROUP SETTING Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. Turn the JOG dial to move the cursor to A-REC/M-DET SETTING, and then turn theSHUTTLE ring to the right. The A-Rec/M-Det Setting menu...
Page 25 - ALARM RECORDING DURATION; RECORD ALARM
24 Pelco Manual C681M-D (2/02) ALARM RECORDING DURATION Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. Turn the JOG dial to move the cursor to A-REC/M-DET SETTING, and then turn theSHUTTLE ring to the right. The A-Rec/M-Det Setting ...
Page 26 - The duration of recording before the alarm occurs depends on the
Pelco Manual C681M-D (2/02) 25 4. Turn the JOG dial to select the option, and then turn the SHUTTLE ring to the right.The option stops flashing. Turning the JOG dial switches the record alarm options as follows: ALL, SEP ALL: Alarm recording of all cameras set to be operated on the Define Alarm Grou...
Page 27 - This menu item
26 Pelco Manual C681M-D (2/02) 6. Do one of the following: • Turn the JOG dial to go to another item in this menu. • Turn the SHUTTLE ring to the left to return to the Menu Setting menu to go to an-other menu. • Press the SET UP button to exit the programming mode. M-DET SETTING Refer to Motion Dete...
Page 28 - OVERWRITE
Pelco Manual C681M-D (2/02) 27 4. Turn the JOG dial to select the option, and then turn the SHUTTLE ring to the right. Turning the JOG dial switches the archive data options as follows: ALL: This backs up all the data recorded on the main hard disk after the archive pointer. Alternatively, all data ...
Page 29 - AUDIO RECORDING; Depending on the setting of the image quality and the maximum; AUTO EJECT
28 Pelco Manual C681M-D (2/02) AUDIO RECORDING The recorder can record audio with an image. Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. Turn the JOG dial to move the cursor to INITIAL SET UP, and then turn the SHUTTLEring to the ...
Page 30 - BUZZER
Pelco Manual C681M-D (2/02) 29 5. Do one of the following: • Turn the JOG dial to go to another item in this menu. • Turn the SHUTTLE ring to the left to return to the Menu Setting menu to go to an-other menu. • Press the SET UP button to exit the programming mode. BUZZER You can set the buzzer to s...
Page 32 - If you selected HDD Data Clear, data will be erased from all
Pelco Manual C681M-D (2/02) 31 4. Turn the JOG dial to select the device. Turning the JOG dial switches the device options as follows: HDD, ARC, NONE Select HDD if the MODE OUT terminal is wired to the record (REC) input of anotherrecorder. 5. Turn the SHUTTLE ring to the right. The percentage optio...
Page 33 - BACKUP FOLLOWING A POWER FAILURE
32 Pelco Manual C681M-D (2/02) 5. Do one of the following: • Turn the JOG dial to go to another item in this menu. • Turn the SHUTTLE ring to the left to return to the Menu Setting menu to go to an-other menu. • Press the SET UP button to exit the programming mode. FIFO/OVERWRITE MODE (DX3016 Models...
Page 34 - REC•STANDBY; ALARM•PROT
Pelco Manual C681M-D (2/02) 33 HARD DISK DRIVE (HDD) FULL When the end of the hard disk drive (HDD) is reached during recording, this function deter-mines what the recorder will do. Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. Tur...
Page 37 - MOTION DETECTION; To set up motion
36 Pelco Manual C681M-D (2/02) 4. Turn the JOG dial to select the option, and then turn the SHUTTLE ring to the right.The option stops flashing. Turning the JOG dial switches the mode out options as follows: REC, PLAY, POWER, REMAIN REC: The signal is output during recording. PLAY: The signal is out...
Page 39 - MULTIPLEXER DISPLAY
38 Pelco Manual C681M-D (2/02) 18. Turn the JOG dial to select the threshold, and then turn the SHUTTLE ring to the right. The option stops flashing. Select a number between 1 and 120. The number is the minimum number of activedots required to initiate alarm recording. When establishing a value for ...
Page 40 - SCREEN SWITCH PATTERN (DX3016 Models Only)
Pelco Manual C681M-D (2/02) 39 Four-Camera (Split 4) Setting In the SPLIT 4 setting mode, you select which camera images to show in a four-cameradisplay. Three different groups of cameras can be defined. Skip steps 1-3 if they have already been done. 1. Press the SET UP button to display the Menu Se...
Page 41 - SPLIT 4 SCREEN SETTING (DX3016 Models Only); SPLIT 9 SCREEN SETTING (DX3016 Models Only)
40 Pelco Manual C681M-D (2/02) SPLIT 4 SCREEN SETTING (DX3016 Models Only) In the Split 4 Screen Setting, you select which camera images to show in a four-cameradisplay. Four different groups of cameras can be defined. Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to ...
Page 43 - SEQUENCE
42 Pelco Manual C681M-D (2/02) SEQUENCE Cameras can be sequenced individually, in groups of four cameras, or, for the DX3016models only, in groups of nine cameras. Set all sequence patterns. These are the patternsthat will be displayed when the SPLIT/SEQUENCE button is pushed (refer to the Operation...
Page 44 - ALARM DISPLAY
Pelco Manual C681M-D (2/02) 43 3. Turn the JOG dial to move the cursor to CH.TITLE, and then turn the SHUTTLE ringto the right. The option starts flashing. NOTE: If the PRE A-REC field in the A-Rec/M-Det Setting menu has been set to SHORT, MEDIUM, or LONG, the option does not flash because it cannot...
Page 46 - Press the SET UP button to exit the programming mode.
Pelco Manual C681M-D (2/02) 45 4. Turn the JOG dial to select the option, and then turn the SHUTTLE ring to the right.The flashing stops. Turning the JOG dial changes the image quality setting as follows: BASIC, STANDARD, MEDIUM, HIGH, SUPERIOR 5. Do one of the following: • Turn the JOG dial to go t...
Page 47 - SELECT RECORDING MODE; When SHORT, MEDIUM, or LONG is selected in the PRE A-REC field in; DEFINE GROUP
46 Pelco Manual C681M-D (2/02) SELECT RECORDING MODE There are three recording modes: A, B, and C. For example, mode A might be used fordaytime recording, mode B for nighttime recording, and mode C for weekend recording.The cameras that will record in each mode are selected in the next section, Defi...
Page 48 - RS-232C COMMUNICATION
Pelco Manual C681M-D (2/02) 47 5. Turn the JOG dial to select the option, and then turn the SHUTTLE ring to the right.The option stops flashing. Turning the JOG dial changes the priority setting as follows: 1, 2, 3, 4, 5, - The - (hyphen) means that camera channel is turned off; that is, if a camera...
Page 49 - RESTORING MENU DATA; Make sure the recorder is turned off.
48 Pelco Manual C681M-D (2/02) SAVING MENU SETTINGS Complex menu settings can be saved on a peripheral recording device connected to SCSIID number 5. These settings also can be read by the recorder from the peripheral device. SAVING MENU DATA If you have previously saved menu settings, saving them a...
Page 50 - This menu is not used.; TIME AND DATE DISPLAY
Pelco Manual C681M-D (2/02) 49 TCP/IP SETTING (DX3016 Models Only) This menu is not used. TIME AND DATE DISPLAY DISPLAY MODE Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. Make sure the cursor is next to TIME DATE DISPLAY, and then ...
Page 51 - CHARACTER SIZE
50 Pelco Manual C681M-D (2/02) 4. Turn the JOG dial to select 1-6, and then turn the SHUTTLE ring to the right. The optionstops flashing. An example of the display mode appears on the screen, as shown inthe chart below. 5. Do one of the following: • Turn the JOG dial to go to another item in this me...
Page 52 - CLOCK LOCATION; TIME AND DATE SETTING
Pelco Manual C681M-D (2/02) 51 CLOCK LOCATION Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. Make sure the cursor is beside TIME DATE DISPLAY, and then turn the SHUTTLEring to the right. The Time Date Display menu appears. 3. Turn t...
Page 53 - TIMER RECORDING
52 Pelco Manual C681M-D (2/02) 8. Do one of the following: • Turn the JOG dial to go to another item in this menu. • Turn the SHUTTLE ring to the left to return to the Menu Setting menu to go toanother menu. • Press the SET UP button to exit the programming mode. TIMER RECORDING When using the timer...
Page 54 - Turning the JOG dial switches the options as follows:; To erase a program entry, press the WARNING RESET button.
Pelco Manual C681M-D (2/02) 53 11. Repeat steps 8-10 for the ending time. A dot between the columns for the starting and ending times indicates that the record-ing time overlaps into the following day; for example, if you select 5 p.m. to 8 a.m. 12. Set the MODE column. Use the JOG dial to select th...
Page 57 - ESTIMATING RECORDING TIME; When setting the timer for multiple programs, refer to the
56 Pelco Manual C681M-D (2/02) <TIMER PROGRAM> P1 DW START END MODE1 DAY 12:00 13:00 DAY 16:00 22:00 3 ——— ——:—— ——:—— 00509 01138 ESTIMATING RECORDING TIME When using the Timer Program, there may be instances where, because of maximum re-cording fields, image quality, and audio recording sett...
Page 58 - OPERATION; Time and Date Display in the Program-
Pelco Manual C681M-D (2/02) 57 01 - 01 - 2000 SAT A0001 00 : 00 : 00 15F 50% C1 Year Month Date Day of the week Alarm recording number Minute Second Time Recording interval Camera number Recorded capacity of the Hard Disk Non-operation camera mark OPERATION Press the POWER button on the front of the...
Page 60 - ZOOM BUTTONS; You cannot operate the ZOOM buttons when a menu is displayed on the; REMOTE VIEWING
Pelco Manual C681M-D (2/02) 59 ZOOM BUTTONS NOTE: You cannot operate the ZOOM buttons when a menu is displayed on the screen. The buttons do not work when the recorder is accessing a peripheralrecording device or the ARCHIVE, COPY, or PLAY button is flashing. 1. Display the Zoom Pointer (X) by press...
Page 61 - ALARM RECORDING
60 Pelco Manual C681M-D (2/02) ALARM RECORDING Alarm recording commences upon either of the following conditions: • An ALARM IN terminal is triggered by an alarm sensor • A camera detects motion When there is an alarm: 1) The recorder switches to its preset recording intervals. Refer to Alarms in th...
Page 62 - To stop timer recording, press the TIMER REC button once more.; PLAYBACK; Press the PLAY button.; in playback and eject, depending on the condition of the recording.; back in the Programming section.; Also refer to the
Pelco Manual C681M-D (2/02) 61 TIMER RECORDING 1. Select the timer program (P1, P2, or P3) that you want to use for recording. Refer toTimer Recording in the Programming section. 2. Press the TIMER REC button. The TIMER REC indicator illuminates. If the current timeis covered by a program, the unit ...
Page 63 - Turn the JOG dial in either direction during still-frame playback.; PAUSE PLAYBACK; Press the PAUSE button to pause playback.; REVERSE PLAYBACK
62 Pelco Manual C681M-D (2/02) FRAME-BY-FRAME (STILL FRAME) PLAYBACK 1. Press the PAUSE button during playback. The unit shifts into still-frame mode. 2. If the screen shows more than one camera, you can view a full-screen view of a singlecamera by pressing the CAMERA button for that camera. 3. Turn...
Page 65 - Index Search
64 Pelco Manual C681M-D (2/02) 4. Turn the JOG dial to move the cursor beside TIME DATE SEARCH, and then turn the SHUTTLE ring to the right. The Time Date Search menu appears and the month num-ber starts flashing. NOTE: If the PRE A-REC field in the A-Rec/M-Det Setting menu has been set to SHORT, ME...
Page 66 - When using DDS tape, index searches can be done in the forward; Skip Search; the menu cannot be accessed.
Pelco Manual C681M-D (2/02) 65 Present position Beginning of playback device End of playback device -15 -1 -2 +1 +15 +2 A•REC A•REC A•REC A•REC A•REC A•REC A•REC: Alarm Recording 6. Turn the SHUTTLE ring in the desired search direction. The present position in the diagram below represents the point ...
Page 68 - assigned to SCSI ID number 4.
Pelco Manual C681M-D (2/02) 67 5. Press the PLAY or PAUSE button to play back the searched image. 6. Press the STOP button to stop playback and exit the search function. PLAYBACK ON ANOTHER DEVICE Data recorded on an external copying or archiving device can be played back on a per-sonal computer or ...
Page 70 - Turn the JOG dial to move the cursor to the stop time.; Still-Frame Playback Copy Mode; Cancelling copy operation
Pelco Manual C681M-D (2/02) 69 SUPERIOR HIGH MEDIUM STANDARD BASIC Non-selectable 30F 15F 7.5F 5F :Simultaneous backup is possible without audio :Simultaneous backup is possible with audio IMAGE QUALITY Field/sec. b. Use the JOG dial and SHUTTLE ring to set the month, date, year, hour, minute,and se...
Page 71 - Precautions when designating simultaneous timer backup; RESTORING DATA FROM A BACKUP DEVICE; Using the COPY Button in the Backing up Data section.
70 Pelco Manual C681M-D (2/02) RECORDING A-7.5F (or POWER setting) Illustration 1: Correct setting Backup Longer than 5 minutes RECORDING A-7.5F (or POWER setting) Backup RECORDING A-7.5F (or POWER setting) Longer than 1 minutes Longer than 1 minutes Illustration 2 3. Precautions when designating si...
Page 72 - To exit the menu, press the INFO button again.; POWER FAILURE LIST; Press the SET UP button to display the Menu Setting menu.
Pelco Manual C681M-D (2/02) 71 INFORMATION ELAPSED TIME DISPLAY 1. Press the INFO button. The Information menu appears. The elapsed time appears inthe lower part of the screen. 2. To exit the menu, press the INFO button again. The elapsed time of main hard disk drive, archive device, and copy device...
Page 73 - RECORDED PERIOD; Press the INFO button. The Information menu appears.; POWER FAILURE; Information, Power Failure List in the Operation section.; RESET
72 Pelco Manual C681M-D (2/02) RECORDED PERIOD The recorded periods of the main hard disk drive, the archive device, and the copy deviceare shown on the screen. The archive device is displayed only when an archive device is connected to ID4. The copy device is displayed only when a copy device is co...
Page 74 - Audio recording not possible.; DX3009 RECORDING TIME TABLES
Pelco Manual C681M-D (2/02) 73 Audio recording possible. (12.8kHz sampling) Audio recording possible, but with diminished quality. (8kHz sampling) Audio recording not possible. ■ Audio recording time table Approximate recording time (if recording is made with internal 30 GB HDD) ♦ Without Audio reco...
Page 75 - SUPERIOR; Pre-alarm recording time table
74 Pelco Manual C681M-D (2/02) 30F 15F 7.5F 5F 3F 1F Field/sec. SUPERIOR HIGH MEDIUM STANDARD BASIC 2s 3s 5s 6s 8s 4s 7s 10s 13s 16s 9s 14s 20s 26s 33s 13s 21s 30s 40s 50s 23s 36s 51s 1min7s 1min24s 1min9s 1min48s 2min33s 3min21s 4min12s IMAGE QUALITY 30F 15F 7.5F 5F 3F 1F 1s 2s 3s 4s 5s 3s 4s 6s 8s...
Page 77 - DX3016 RECORDING TIME TABLES
76 Pelco Manual C681M-D (2/02) Audio recording possible. (12.8kHz sampling) Audio recording possible, but with diminished quality. (8kHz sampling) Audio recording not possible. ■ Audio recording time table Approximate recording time (if recording is made with internal 60 GB HDD) • This recording tim...
Page 79 - Audio recording, recording duration is set to MEDIUM.
78 Pelco Manual C681M-D (2/02) DX3016 RECORDING TIME TABLES (Continued) Audio recording possible. (12.8kHz sampling) Audio recording possible, but with diminished quality. (8kHz sampling) Audio recording not possible. ♦ Audio recording, recording duration is set to MEDIUM. ♦ Audio recording, recordi...
Page 80 - WARNINGS; Options in the CALL OUT options column:
Pelco Manual C681M-D (2/02) 79 WARNINGS The following table tells you what to do if a warning appears on your monitor. Options in the CALL OUT options column: • Selectable: CALL OUT output can be selected or deselected in the Call Out setting inthe Rear Terminal menu and the HDD Full setting in the ...
Page 81 - TROUBLESHOOTING
80 Pelco Manual C681M-D (2/02) Description of problem Please consult the following The unit will not turn on. Power is on, but the unit will notoperate. Images are not appearing on themonitor. The quality of the monitor picture is poor. The unit will not start recording. The unit will not stop recor...
Page 82 - Description of problem
Pelco Manual C681M-D (2/02) 81 O T HERS Description of problem Please consult the following The unit will not respond to PC control. The DEVICE CHECK menu doesappear when power is turned on. The unit is not detecting its peripheralrecording device(s). Black screens are being displayedduring multi-sc...
Page 83 - SPECIFICATIONS
82 Pelco Manual C681M-D (2/02) SPECIFICATIONS ELECTRICAL/VIDEO/AUDIO Input Voltage: 100-240 VAC, 50/60Hz Power Consumption: 150W maximum Signal System: NTSC Recording System: Digital recording system with JPEG compression method Sampling: 13.5 MHz Data Compression: JPEG Compression Unit: Field Audio...
Page 84 - GENERAL
Pelco Manual C681M-D (2/02) 83 Inputs/Outputs POWER ON: Input for power ON. Low input state is power off; high inputstate is power on. POWER OFF: Input for power OFF. Low input state is power off. ALARM IN (1-9): Inputs for starting alarm recording. Active: When terminalsare short-circuited or “Low”...
Page 85 - WARRANTY AND RETURN INFORMATION; REVISION HISTORY; REGULATORY NOTICES
84 Pelco Manual C681M-D (2/02) ® Pelco, the Pelco logo, Spectra, Genex, and Legacy are registered trademarks of Pelco. © Copyright 2002, Pelco. ™ Esprit, Camclosure, and PelcoNet are trademarks of Pelco. All rights reserved. WARRANTY AND RETURN INFORMATION REVISION HISTORY Manual # Date Comments C68...