Page 2 - CONTENTS; Section; SELECTING THE CORRECT RECEIVER FOR; ii
18 Pelco Manual C505M-B (4/97) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 1 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 1 2.0 DESCRIPTION .................................................
Page 3 - Original version; iii
Pelco Manual C505M-B (4/97) 19 LIST OF ILLUSTRATIONS Figure Page 1 Typical Coaxitron Application ............................................................. 3 2 Typical RS-485 Control Applications .................................................. 4 3 Receiver Connector Locations ....................
Page 4 - iv
20 Pelco Manual C505M-B (4/97) (This page intentionally left blank.) iv
Page 5 - Only use replacement parts recommended by Pelco.; The product may bear the following marks:; RISK OF
Pelco Manual C505M-B (4/97) 1 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should beobserved. 1. Installation and...
Page 6 - Any feature and/or option
2 Pelco Manual C505M-B (4/97) 2.0 DESCRIPTION The Coaxitron ® System 9500 receivers are available in two control formats and work with all Coaxitron controls. The control formats are as follows: 1. CX9500 Coaxitron control 2. CX9504 RS-485 4-wire control Standard features for all receivers include: ...
Page 7 - A typical application is given in Figure 1.; Typical Coaxitron Application
Pelco Manual C505M-B (4/97) 3 3.0 INSTALLATION 3.1 SELECTING THE CORRECT RECEIVER FOR YOUR APPLICATION Successful installation must include proper application planning. The trade-offs andapplication hints that should be considered for each receiver type are discussed inthe following subsections. 3.1...
Page 8 - Typical RS-485 Control Applications
4 Pelco Manual C505M-B (4/97) Figure 2. Typical RS-485 Control Applications 3.1.2 The CX9504 4-Wire RS-485 Control System This system is used in applications where multiple receivers will listen to a singlecontrol channel, but duplex operation is desired. The RS-485 system presents sev-eral unique i...
Page 9 - CONNECTING THE RECEIVER; CPC 37-PIN Connector Pinout; Receiver Connector Locations
Pelco Manual C505M-B (4/97) 5 3.2 CONNECTING THE RECEIVER Connecting the receiver involves mating the correct connector assembly to theappropriate receiver connector (J6 or J7) on the Coaxitron unit. See Figure 3. Receiver connector locations are listed as follows: BNC-1** Video input from cameraBNC...
Page 10 - Connector Assembly; Prepare the wires from the conductor cable as follows:; Contacts cannot be re-; OR; FRONT VIEW
6 Pelco Manual C505M-B (4/97) Figure 4. Connector Assembly 3.2.1 Connector Assembly If you did not order a pre-assembled connector, assemble the connector parts ac-cording to the instructions below. Detail B, below, reflects the pin arrangement spe-cific to CX9500/CX9504 Receivers. Refer to Figure 4...
Page 11 - s pulse; “PP” Option
Pelco Manual C505M-B (4/97) 7 4.0 OPERATION Upon applying power, the receiver will perform its self-test functions. These diag-nostics determine the receiver, pan and tilt, lens and camera configuration by exer-cising each. The results are reported by text superimposed on the video if the textgenera...
Page 12 - Receiver Board Locations
8 Pelco Manual C505M-B (4/97) 5.0 CX9500 RECEIVER BOARD DESCRIPTIONS The CX9500 Receiver contains three boards: the Mother Board, the Option Board,and the Power Supply Board. Gaining access to the board slot locations can beseen in Figure 5. As part of any operational set-up, the Option and Power Su...
Page 13 - Prior to operation, both the
Pelco Manual C505M-B (4/97) 9 5.2 OPTION BOARD This board contains all the circuitry required for all options. The components will beloaded or not loaded according to the model being built. Preset circuits are loadedfor preset (PP). Receiver Address circuits are loaded for the 9504 versions of there...
Page 14 - Options Board Address Settings; OPTIONS BOARD
10 Pelco Manual C505M-B (4/97) Figure 6. Options Board Address Settings 2 2 2 2 2 2 2 2 7 6 5 4 3 2 1 0 SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 ON RECEIVERADDRESS Binary Weight Position SpecificDecimal Equivalent 128 64 32 16 8 4 2 1 1 2 3 4 5 6 15 255 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 1 0 0 0 0...
Page 15 - Universal AC Power Suppy Board; Variable Speed Power Suppy Board
Pelco Manual C505M-B (4/97) 11 Figure 8. Variable Speed Power Supply Board Figure 7. Universal Power Supply Board JP2 JP4 JP6 JP8 JP10 JP12 JP14 JP16 JP18 JP1 JP3 JP5 JP7 JP9 JP11 JP13 JP15 JP17 Typical Jumper Wiresupplied in plastic bag along with fuses Universal AC Power Suppy Board JP2 JP8 JP7 JP...
Page 16 - The AC line voltage; Strapping Configurations for Universal AC Power Supply; INPUT VOLTAGE
12 Pelco Manual C505M-B (4/97) WARNING: The AC line voltage used to power the receiver/driver isthe same voltage that is fed throughthe pan/tilt into the enclosure as “en-closure power”, which also suppliesthe heaters and blower where appli-cable. This voltage is not selectable. INPUT VOLTAGE 24 VAC...
Page 17 - FIRMWARE DESCRIPTIONS; PROGRAMMED AUX FUNCTIONS
Pelco Manual C505M-B (4/97) 13 6.0 FIRMWARE DESCRIPTIONS 6.1 BAUD RATES The hardware architecture between the controller and receiver is an RS-485 circuitdesignated the “control channel”. The baud rate is currently set to 2400 baud. Theinformation is processed by the receiver every 16 ms. Higher bau...
Page 18 - ELECTRICAL; All standard baud rates from
14 Pelco Manual C505M-B (4/97) 7.0 SPECIFICATIONS ELECTRICAL Input Voltage (50/60 Hz): StandardVersion 24, 120, 230 VAC VS Version 120, 230 VAC Power Consumption (excluding PTZ): StandardVersion 6 watts VS version 6 watts P/T Output Voltages: StandardVersion 24, 120, 230 VAC VS Version 12 VDC PWM at...
Page 19 - MECHANICAL; Options; GENERAL; CM9500 Series Receiver/Driver Dimension Drawing; NOTE: VALUES SHOWN IN PARENTHESES ARE CENTIMETERS
Pelco Manual C505M-B (4/97) 15 MECHANICAL Connectors: P/T 37-pin CPC Options 37-pin CPC Video 2 BNCs Power 3-wire #18 Awg Fuse 2 AG, 1/2 amp GENERAL Ambient OperatingTemperature: -4 ° to 140 ° F (-20 ° to 60 ° C) Dimensions: See Figure 9. Figure 9. CM9500 Series Receiver/Driver Dimension Drawing 9.1...
Page 20 - WARRANTY AND RETURN INFORMATION; WARRANTY
16 Pelco Manual C505M-B (4/97) 8.0 WARRANTY AND RETURN INFORMATION Pelco, the Pelco logo, Camclosure, Esprit,Genex, Legacy, and Spectra are registeredtrademarks of Pelco.Endura and ExSite are trademarks of Pelco. © Copyright 1997, Pelco. All rights reserved. WARRANTY Pelco will repair or replace, wi...