Pelco CM9505UPS-422X - Manual

Pelco CM9505UPS-422X

Pelco CM9505UPS-422X – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – INSTALLATION; The following parts are supplied:
  • Page 3 – CPU and Keyboard Terminal Assignments; Ground; Wall Block Terminal Assignments
  • Page 4 – REVISION HISTORY; Date; Revised to include UL and cUL markings.; REGULATORY NOTICES; PRODUCT WARRANTY AND RETURN INFORMATION; WARRANTY
Loading the manual

C1430M-D (8/01)
CM9505J Junction Box
CM9505UPS Universal Power Supply

®

IMPORTANT SAFEGUARDS AND WARNINGS

Prior to installation and use of this product, the following WARNINGS should be observed.

1.

Installation and servicing should only be done by qualified service personnel and conform
to all local codes.

2.

Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure,
it is designed for indoor use only.

3.

To reduce risk of fire or electric shock, do not expose this product to rain or moisture.

4.

Only use replacement parts recommended by Pelco.

The product and/or manual may bear the following marks:

Please thoroughly familiarize yourself with the information in this manual prior to installation and
operation.

DESCRIPTION

The CM9505J Junction Box and the CM9505UPS Universal Power Supply are used with
CM8500 and CM9500 matrix systems to allow the system keyboards to be placed at remote
locations throughout a facility.

The junction box can be used by itself, but in most applications is used in conjunction with the
power supply (refer to Figure 1). When used together, the junction box allows you to convert a
keyboard cable into a set of cabling that can be run significantly greater distances by eliminating
the keyboard power connections and only running the data. The CM9505UPS Universal Power
Supply reintroduces the keyboard power at the keyboard end of the cabling. For distances over
2,000 feet (609.6 m), the CM9505UPS-422 Universal Power Supply with data repeater is recom-
mended.

Communication between each keyboard and the CPU consists of two RS-422 data pairs,
+12 VDC, -12 VDC, and a ground, for a total of seven conductors. The junction boxes, power
supplies, and keyboards are supplied with 25-foot (7.6 m) pretested interconnect cables with
pre-assembled RJ-45 modular 8-pin male connectors.

Models

CM9505J

Junction box only, for CM8500 and CM9500 matrix system keyboards

CM9505UPS

Power supply only, for CM8500 and CM9500 matrix system keyboards
(UL, cUL)

CM9505UPS-X

Same as CM9505UPS, except 230 VAC (CE)

CM9505UPS-422

Same as CM9505UPS, except with data repeater function (FCC, UL, cUL)

CM9505UPS-422X

Same as CM9505UPS-422, except 230 VAC (CE)

This symbol indicates that danger-
ous voltage constituting a risk of
electric shock is present within this
unit.

This symbol indicates that there
are important operating and main-
tenance instructions in the litera-
ture accompanying this unit.

C A U T I O N :

RISK OF ELECTRIC SHOCK.

DO NOT OPEN.

3500 Pelco Way
Clovis, CA 93612-5699
USA

In North America & Canada:
Tel (800) 289-9100
FAX (800) 289-9150

International Customers:
Tel +1(559) 292-1981
FAX +1(559) 348-1120

www.pelco.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; The following parts are supplied:

MATRIX SYSTEM CARD CAGE REMOTE KEYBOARD DATA CABLE SUPPLIED WITH KEYBOARD DATA CABLE SUPPLIED WITH UPS CM9505UPS USER SUPPLIED 4-CONDUCTOR DATA CABLE SUPPLIED WITH JUNCTION BOX CM9505J JUNCTION BOX MATRIX SYSTEM CARD CAGE REMOTE KEYBOARD DATA CABLE SUPPLIED WITH KEYBOARD USER SUPPLIED 8-CONDUCTOR DA...

Page 3 - CPU and Keyboard Terminal Assignments; Ground; Wall Block Terminal Assignments

Table A. CPU and Keyboard Terminal Assignments CPU Keyboard Terminal Function Function Terminal 1 Data in + Data out + 1 2 Data in - Data out - 2 3 -12 VDC -12 VDC 3 4 +12 VDC +12 VDC 4 5 Ground Ground 5 6 Spare Spare 6 7 Data out - Data in - 7 8 Data out + Data in + 8 1 2 3 4 5 6 7 8 Figure 2. Wall...

Page 4 - REVISION HISTORY; Date; Revised to include UL and cUL markings.; REGULATORY NOTICES; PRODUCT WARRANTY AND RETURN INFORMATION; WARRANTY

REVISION HISTORY Manual # Date Comments C1430M Original version. C1430M-A 11/98 Changed manual to new format. Revised installation instructions and added Figure 4 per PAR #98019. C1430M-B 7/99 Incorporated ECO 99-4999 . Updated to new format. C1430M-C 6/01 Revised to include safety warning and updat...

Other Pelco Models

All Pelco Other