C3611M (12/07)
1
CONNECT THE EDI5000-AD2088 TO AN AD MATRIX SYSTEM
Figure 1.
Connect the EDI5000 to the AD Matrix System
z
NOTE:
The alarm and relay inputs on the data interface are reserved for
future use, and are not included in this table.
Table A.
EDI5000 and AD2088 RS-232 Pin Assignments
Pin Assignment
AD2088 Keyboard
EDI5000 COM 1
RS-232 Data Rx+
PIN 5
PIN 1
Ground
PIN 7
PIN 5
RS-232 Data Tx+
PIN 4
PIN 9
Pin Assignment
AD Matrix
EDI5000 COM 2
RS-232 Data Rx+
PIN 5
PIN 2
Ground
PIN 7
PIN 6
RS-232 Data Tx+
PIN 4
PIN 10
2
1
9
10
8
6
4
2
7
5
3
1
AD MATRIX
C
AMERA 1
C
AMERA 2
MATRIX MONITOR
1
2
3
4
8
7
6
5
5
6
7
8
4
3
2
1
C
OM 1
C
OM 2
Rx+
Tx+
GND
GND
Rx+
Tx+
EDI5000-AD2088
REVER
S
ED
DATA
C
ABLE
AD DUAL 8-PIN
TERMINAL BLO
C
K
9 VA
C
REVER
S
ED
DATA
C
ABLE
AD2088 MATRIX KEYBOARD
C3611M (12/07)
EDI5000-AD2088 Data Interface