Page 2 - CONTENTS; Section
2 Pelco Manual C2423M (5/00) CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ................................................................ 3OPERATION ...................................................................................................................... 4 POWER-UP DISPLAY ....
Page 3 - IMPORTANT SAFEGUARDS AND WARNINGS; Only use replacement parts recommended by Pelco.; MEASURES DE SECURITE IMPORTANTES
Pelco Manual C2423M (5/00) 3 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel andconform to all local codes. 2. Unless the unit is specifically ...
Page 4 - OPERATION; OPERATING YOUR SPECTRA II COLOR/BLACK & WHITE DOME; Protocol C
4 Pelco Manual C2423M (5/00) OPERATION POWER-UP DISPLAY When the Spectra II™ dome is powered up, the selected protocol, revision number, andother information is displayed on the monitor. For example, the screen might show thefollowing information: The information displayed depends on the selectedpro...
Page 6 - The dome cannot
6 Pelco Manual C2423M (5/00) PATTERNS The Spectra II dome can do either one full pattern (1.5, 3, or 6 minutes long) or two halfpatterns (.75, 1.5, or 3 minutes long). This pattern can consist of any standard pan and tiltor lens command. Presets, flip, and turbo are not allowed in a pattern. Zone sc...
Page 7 - Park; IR FILTER; Hold down the Iris Open button until the iris is wide open.
Pelco Manual C2423M (5/00) 7 AUXILIARY OUTPUTS An AUX 1 command from the controller will activate the relay in the dome and operate thedevice that is connected to the relay. The relay will remain latched until a clear command isissued. An AUX 2 command from the controller will place a ground at the ...
Page 8 - PROGRAMMING; For detailed instructions, refer to the following sections.; MAIN MENU
8 Pelco Manual C2423M (5/00) PROGRAMMING Programming Guide - Spectra II Color/Black & White 1. Access main menu (preset 95). 2. Make main menu selections.Joystick: Move up or down to position cursor orto toggle between selections. Iris Open: EnterIris Close: Cancel PRESETS The following presets ...
Page 10 - Pattern length is set; ALARM PATTERN
10 Pelco Manual C2423M (5/00) ALARMS The Spectra II dome has seven alarm inputs, which can be designated as either high or lowpriority. The high priority setting is significant when more than one alarm is activated. If priority inalarms is not required, leave all alarms in the low setting. Refer to ...
Page 11 - The Spectra II; ALARM RESUME
Pelco Manual C2423M (5/00) 11 6. Position the cursor (>) beside the number of the alarm input for which you want to setthe pattern. 7. Press the Iris Open button. The cursor moves to the right, beside the words Full Pat,Half Pat 1, Half Pat 2, or No Pattern. 8. Move the joystick up or down to tog...
Page 13 - AUTO IRIS; The following are the settings for auto iris:
Pelco Manual C2423M (5/00) 13 AUTO IRIS The following are the settings for auto iris: ModeLevel To change the settings for auto iris:1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Camera. 3. Press the Iris Open button to enter the Camera menu. 4. Position the ...
Page 14 - AUTO IR LEVEL; /60 second shutter speed; Slow shutter operation affects the auto IR level setting.; Slow Shutter Mode section.; AUX MODE
14 Pelco Manual C2423M (5/00) AUTO IR LEVEL The IR level setting determines when the IR filter will switch IN or OUT. Following are theavailable settings for the Auto IR Level: Dusk = 1/60 second shutter speed2 = 1/60 second shutter speed 3 = 1/30 second shutter speed Dark = 1/15 second shutter spee...
Page 15 - BACKLIGHT COMPENSATION; If backlight; in
Pelco Manual C2423M (5/00) 15 There are two backlight compensation modes: On - The dome uses the center 10 percent of the picture to adjust the iris. If there is a bright light source outside of this area, it will wash out to white. The camera willadjust the iris so that the object in the sensitive ...
Page 16 - AGC MODE; GAIN; Press the Iris Open button to enter the Camera menu.
16 Pelco Manual C2423M (5/00) Main Menu <Camera><Line Sync><Power Up><Aux><Alarms, Zone Blank><Other>EXIT Camera Menu Backlight comp Off Zoom limit x72 Reset camera<Gain/AGC><Auto-iris><Next>Exit Gain/AGC Menu AGC mode Auto Gain 6 Exit Gain - The...
Page 17 - IR FILTER MODE; CAMERA SETTING; LIMIT STOPS
Pelco Manual C2423M (5/00) 17 Next Menu Slow shutter mode Auto Shutter speed Auto Auto focus mode Auto <IR Filter><Sharpness><White balance>PreviousExit Main Menu <Camera><Line Sync><Power Up><Aux><Alarms, Zone Blank><Other>EXIT Camera Menu Backl...
Page 18 - Programming; TURNING LIMIT STOPS ON OR OFF; Press the Iris Open button to enter the Other menu.; Scan Limit Stops; Make sure limit stops are turned ON, and then exit the menu.; LINE SYNCHRONIZATION
18 Pelco Manual C2423M (5/00) NOTE: Programming preset 90 (23) disables themanual limit stops untilpreset 91 (24) is set. TURNING LIMIT STOPS ON OR OFF To change the limit stop mode:1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Other. 3. Press the Iris Open b...
Page 19 - PARK TIME MINUTES; Preset 1 must be; PATTERN LENGTH; If the; The Spectra II dome can do the following:
Pelco Manual C2423M (5/00) 19 LINE SYNC PHASE - The cursor moves to a numeric value. Move the joystick up or down to change the value. Press the Iris Open button to select the choice. The value represents thephase angle in tenths of a degree between 0 degrees and 359 degrees. For example, 900 is90 d...
Page 20 - PROPORTIONAL PAN
20 Pelco Manual C2423M (5/00) Main Menu <Camera><Line Sync><Power Up><Aux><Alarms, Zone Blank><Other>EXIT Other Menu Auto flip On Proportional pan On Limit stops Off Park time minutes 0 Scan speed deg/s 25 Pattern length 1.5 min Exit There are two proportional pan...
Page 21 - RESET CAMERA
Pelco Manual C2423M (5/00) 21 3. Press the Iris Open button to enter the Other menu. 4. Position the cursor (>) beside Proportional Pan. 5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off. 6. Move the joystick up or down to toggle between On and Off. 7. SELECT...
Page 22 - SCAN SPEED; SHARPNESS; Do the following to manually adjust the sharpness of the picture:
22 Pelco Manual C2423M (5/00) SCAN SPEED Next Menu Slow shutter mode Auto Shutter speed Auto Auto focus mode Auto <IR Filter><Sharpness><White balance>PreviousExit Main Menu <Camera><Line Sync><Power Up><Aux><Alarms, Zone Blank><Other>EXIT Main M...
Page 23 - SHUTTER SPEED; There are several electronic shutter speed settings:
Pelco Manual C2423M (5/00) 23 SHUTTER SPEED Next Menu Slow shutter mode Auto Shutter speed Auto Auto focus mode Auto<IR Filter><Sharpness><White balance>PreviousExit Main Menu <Camera><Line Sync><Power Up><Aux><Alarms, Zone Blank><Other>EXIT Came...
Page 24 - SLOW SHUTTER MODE; There are two settings in the slow shutter mode:
24 Pelco Manual C2423M (5/00) SLOW SHUTTER MODE Next Menu Slow shutter mode Auto Shutter speed Auto Auto focus mode Auto<IR Filter><Sharpness><White balance>*PreviousExit Main Menu <Camera><Line Sync><Power Up><Aux><Alarms, Zone Blank><Other>EXIT...
Page 25 - WHITE BALANCE; RED BALANCE and BLUE BALANCE LEVELS -; ZONES
Pelco Manual C2423M (5/00) 25 WHITE BALANCE Next Menu Slow shutter mode Auto Shutter speed Auto Auto focus mode Auto <IR Filter><Sharpness><White balance>PreviousExit Main Menu <Camera><Line Sync><Power Up><Aux><Alarms, Zone Blank><Other>EXIT Cam...
Page 26 - ZOOM LIMIT; Press the Iris Open button to enter the Alarms, Zone Blank menu.; ZONE BLANK
26 Pelco Manual C2423M (5/00) NOTE: The Spectra II Color/Black and Whitecamera cannot do electroniczoom in a pattern. Opticalzoom will operate in apattern. Main Menu <Camera><Line Sync><Power Up><Aux><Alarms, Zone Blank><Other>EXIT Camera Menu Backlight comp Off Z...
Page 27 - SPECIFICATIONS; MECHANICAL; CAMERA; MAINTENANCE; DOME CLEANING; SERVICE MANUAL
Pelco Manual C2423M (5/00) 27 SPECIFICATIONS MECHANICAL Pan Movement: 360 ° continuous pan rotation Vertical Tilt: Unobstructed +2 ° to -92 ° Manual Pan/Tilt Speeds* Pan: 0.1 ° -80 ° /sec manual operation, 150 ° /sec turbo Tilt: 0.1 ° -40 ° /sec Preset Speeds Pan: 250 ° /sec Tilt: 200 ° /sec * For v...
Page 28 - REVISION HISTORY
28 Pelco Manual C2423M (5/00) Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. © Copyright 2000, Pelco. Endura and ExSite are trademarks of Pelco. All rights reserved. U.S. Patent No. 5,931,432. REVISION HISTORY Manual # Date Comments C2423M 5...