Page 2 - CONTENTS; Section
2 Pelco Manual C1456M-D (10/98) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 7 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 71.2 REGULATORY NOTICES ..........................................
Page 3 - LIST OF ILLUSTRATIONS; Figure; LIST OF TABLES; Table
Pelco Manual C1456M-D (10/98) 3 5.11.17 Alarm Pattern ...................................................................... 465.11.18 Zone Blank ......................................................................... 465.11.19 Auto Flip ...............................................................
Page 4 - REVISION HISTORY; Date; Added standard heater and sun shield.
4 Pelco Manual C1456M-D (10/98) REVISION HISTORY Manual # Date Comments C1456M 3/97 Original version. 4/97 Added instructions for assembling T-rail clip for metalpanel per ECO 97-134. C1456M-A 4/97 Revision A. Added pendant models. 5/97 Added standard heater and sun shield. C1456M-B 7/97 Added Rev. ...
Page 5 - Manual name changed to Spectra
Pelco Manual C1456M-D (10/98) 5 C1456M-D 8/98 Manual name changed to Spectra ® (Software Version 3.0). In Section 2.2, revised the certifications. In Section5.1, added information about selectable power-up mode.In Section 5.2, revised information about high zoom inturbo mode. Added Section 5.2.2, Sc...
Page 8 - Unpack and inspect all parts carefully.
8 Pelco Manual C1456M-D (10/98) 1.2 REGULATORY NOTICES NOTE: This equipment has been tested and found to comply with the limits of aClass A digital device, pursuant to part 15 of the FCC rules. These limits are de-signed to provide reasonable protection against harmful interference when theequipment...
Page 9 - Figure 2. Back Box Parts; The Spectra; Back Box
Pelco Manual C1456M-D (10/98) 9 COMPASS TOOL SAFETY BRACKET CONDUIT FITTING& LOCK NUT T-RAIL CLIP Figure 2. Back Box Parts Figure 1. In-Ceiling Components BACKBOX DOMEDRIVE LOWERDOME 1.3.1 In-Ceiling Models The Spectra ® (Version 3.0) dome shipping carton contains three boxes, plus the C1456M-D ...
Page 10 - Figure 3. Pendant Components
10 Pelco Manual C1456M-D (10/98) Figure 3. Pendant Components BACKBOX DOMEDRIVE LOWERDOME 1.3.2 Pendant Models The Spectra ® (Version 3.0) dome shipping carton contains three boxes, plus the C1456M-D system manual that covers everything in the system (back box, domedrive, and lower dome). Inspect ea...
Page 11 - RECOMMENDED TOOLS; To install the back box:
Pelco Manual C1456M-D (10/98) 11 1.4 RECOMMENDED TOOLS Pelco does not supply basic tools needed for the installation process. The followingtools are recommended. To install the back box: Small flat screwdriverBNC crimp toolWire stripperWire cutterPen or pencil (in-ceiling models only)Drill with 3/32...
Page 14 - Be careful; CEILING AND BACK BOX PREPARATION; Carefully cut the circle out of the ceiling.
14 Pelco Manual C1456M-D (10/98) Figure 4. Compass Tool Figure 5. Conduit Fitting Installation ATTACH SAFETY CHAIN HERE CAUTION: Be careful not to cut outside of theline. If you do, you may notbe able to install the backbox. Also, the trim ringmay not cover the hole. NOTE: Use the SCA1 (structural c...
Page 15 - Figure 6. Installing Back Box; Remove the ceiling tile from the ceiling.
Pelco Manual C1456M-D (10/98) 15 CAUTION: The ceiling tile must be capable ofs u p p o r t i n g 1 6 p o u n d s(7.3 kg) of weight. If theceiling tile will not supportt h i s w e i g h t , o r d e r t h eSD5-P metal panel. CAUTION: Be careful not to cut outside of theline. If you do, you may notbe a...
Page 16 - Figure 8. Wiring Diagram; The dome will stop oper-
16 Pelco Manual C1456M-D (10/98) Figure 8. Wiring Diagram NOTE: The dome will stop oper- ating if the voltage at the domedrops below 18 VAC. It will turnback on when the voltage exceeds18 VAC. 3.2 WIRING Bring wiring to the back box opening in the ceiling. Do not attach the wiring to theback box. Yo...
Page 17 - Table A. Video Coaxial Cable Wiring Distances; Maximum Distance; Table B. 24 VAC Wiring Distances; A dome that requires; Wire Gauge; Maximum distance from transformer to load
Pelco Manual C1456M-D (10/98) 17 Table A. Video Coaxial Cable Wiring Distances Cable Type* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) * Minimum cable requirements: 75 ohms impedance. All-copper center conductor. All-copper braidedshield with 95% braid cover...
Page 18 - If; Figure 9. Interconnect Door; THUMBSCREW; BACK BOX INSTALLATION; The ceiling
18 Pelco Manual C1456M-D (10/98) OPTIONAL PROCEDURE: If you prefer, you may make the wir-ing connections inside the back boxbefore installing the back box in theceiling. To do this, loosen the thumbscrewinside the back box and open thehinged door (refer to Figure 9).Bring the wiring into the back bo...
Page 19 - Figure 11. Interconnect Circuit Board; Electrical Connections; Figure 10. Transformer Wiring; If each; BACK BOX CONNECTIONS; Video - Connect the coaxial cable to the BNC video connector.; controller, control signals will be trans-; From controller
Pelco Manual C1456M-D (10/98) 19 Figure 11. Interconnect Circuit Board Electrical Connections Figure 10. Transformer Wiring EXAMPLE: If each dome requires 20 vA,three domes require a60 vA transformer. DOME 1POWER DOME 2POWER DOME 3POWER WARNING: Make sure you wire power to theouter connectors of the...
Page 20 - Close the door and tighten the thumbscrew securely.
20 Pelco Manual C1456M-D (10/98) NOTE: Connect only a low volt- age device to the relay output.Maximum current rating of the re-lay contacts is two amperes. CAUTION: The maxi- mum output of AUX 2 is150 mA. If you connect adevice that draws morecurrent, you could destroythe output transistor. Theo u ...
Page 21 - Table C. Switch Settings for SW1; Control Type; Figure 12. Switch Locations
Pelco Manual C1456M-D (10/98) 21 Table C. Switch Settings for SW1 Control Type Switch Setting SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 Coaxitron ® OFF OFF OFF OFF OFF OFF OFF OFF** P-Type Control ON OFF OFF OFF OFF OFF OFF OFF** D-Type Control OFF ON OFF OFF OFF OFF OFF* OFF** NOTES: Switches...
Page 22 - Table D. Switch Settings for SW2 – P-Type Control; For Coaxitron; Receiver Address
22 Pelco Manual C1456M-D (10/98) Table D. Switch Settings for SW2 – P-Type Control NOTES: For Coaxitron ® controls, all switches on SW2 MUST be OFF. For D-type control systems, refer to Table E. Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 1 OFF OFF OFF OFF OFF 2 ON OFF OFF OFF OFF ...
Page 23 - Table E. Switch Settings for SW2 – D-Type Control
Pelco Manual C1456M-D (10/98) 23 Table E. Switch Settings for SW2 – D-Type Control NOTES: For Coaxitron ® controls, all switches on SW2 MUST be OFF. For P-type control systems, refer to Table D. Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 1 ON OFF OFF OFF OFF OFF ...
Page 28 - Figure 14. Lower Dome Installation, Pendant Models; If outdoors, apply Duct; INSTALLATION FOR PENDANT MODELS
28 Pelco Manual C1456M-D (10/98) Figure 14. Lower Dome Installation, Pendant Models NOTE: If outdoors, apply Duct Seal inside the pipe portion of theback box to prevent moisture orcold air inside the mount from en-tering the unit and causing conden-sation on the dome. Make sure nomoisture has conden...
Page 29 - For hard ceilings, such as
Pelco Manual C1456M-D (10/98) 29 NOTE: For hard ceilings, such as concrete, where the wiring must beinstalled in surface-mounted con-duit, use the optional BB5-PCA-BK(black) or BB5-PCA-GY (gray) Pen-dant Conduit Adapter. 9. Look inside the lower dome and note which of the six retainer screws is clos...
Page 30 - Protocol C; PAN AND TILT FUNCTIONS
30 Pelco Manual C1456M-D (10/98) 5.0 OPERATION The red LED in the interconnect door in the back box lights when power is turnedon and the fan operates to exhaust heat from inside the back box. If you have an outdoor pendant model with a heater, the heater elements in theback box turn on at 70 ° F (2...
Page 31 - PRESET FUNCTIONS; If you are using the Spec-
Pelco Manual C1456M-D (10/98) 31 5.2.1 Auto Flip When the camera tilts downward and goes just beyond the vertical position, the domerotates 180 degrees. When the dome rotates (flips), the camera starts moving upwardas long as you continue to hold the joystick in the down position. Once you let go of...
Page 32 - If any of presets 1-7 are
32 Pelco Manual C1456M-D (10/98) 5.5 RANDOM, FRAME, AND AUTO SCANNING Program preset 97 (30) to start random scanning. Program preset 98 (31) to acti-vate frame scanning (three seconds of scanning followed by a three-second pause).Program preset 99 (32) to start auto (continuous) scanning. Scan limi...
Page 33 - AUXILIARY OUTPUTS
Pelco Manual C1456M-D (10/98) 33 In certain situations, the dome will respond as follows: • If a preset has not been set, but an alarm is connected: the dome will go to afactory preset that will not be the desired position. • If one alarm is a preset and another is a pattern and both are received: t...
Page 48 - Manual Limit Stops; Programming preset 90
48 Pelco Manual C1456M-D (10/98) 5.11.21 Limit Stops There are two types of limit stops: Manual limit stopsScan limit stops When manual limit stops are set, a manual (joystick) pan operation will stop when alimit stop is reached. When scan limit stops are set, the dome will reverse direction during ...
Page 49 - Preset 1 must be pro-
Pelco Manual C1456M-D (10/98) 49 5.11.22 Park Time Minutes This feature causes the dome to park at preset 1 after a programmed number ofminutes of control inactivity. The time can be set from 1 minute to 720 minutes (12hours), or it can be set to zero, which disables this feature. To change the park...
Page 50 - Press the Iris Open button to enter the submenu entitled Other.; If the length
50 Pelco Manual C1456M-D (10/98) 5.11.24 Pattern Length You can set the pattern length to 1.5, 3, or 6 minutes or have two half-patterns of.75, 1.5, or 3 minutes long. To set the pattern length:1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESETFUNCTIONS) to access the main m...
Page 51 - The dome drive contains no
Pelco Manual C1456M-D (10/98) 51 6.0 TROUBLESHOOTING Symptom: Unit does not operate.1. Make sure your controller is trying to communicate with the unit and not an-other camera. 2. Turn off power. 3. Remove the lower dome: In-Ceiling Models - Insert the flat blade of a screwdriver into one of the slo...
Page 52 - BACK BOX ELECTRONIC ASSEMBLY REMOVAL
52 Pelco Manual C1456M-D (10/98) Symptom: Fan does not operate.1. Turn off power. 2. Remove the lower dome: In-Ceiling Models - Insert the flat blade of a screwdriver into one of the slotson the trim ring and twist the screwdriver to pop loose the trim ring and lowerdome. Pendant Models - Remove the...
Page 54 - Figure 16. SD5 Series Dimension Drawing
54 Pelco Manual C1456M-D (10/98) 8.0 SPECIFICATIONS MECHANICAL Construction Back box: Aluminum Dome drive: Aluminum, ABS plastic Lower dome: Acrylic Cable Entry In-Ceiling: .75" (1.91 cm) conduit fitting Pendant: Through 1.5" (3.81 cm) NPT pendant mount Pan Movement: 360 ° Continuous pan rot...
Page 57 - NOTES
Page 58 - WARRANTY AND RETURN INFORMATION; WARRANTY; RETURNS
58 Pelco Manual C1456M-D (10/98) 9.0 WARRANTY AND RETURN INFORMATION Pelco, the Pelco logo, Camclosure, Esprit,Genex, Legacy, and Spectra are registeredtrademarks of Pelco.Endura and ExSite are trademarks of Pelco. © Copyright 1998, Pelco. All rights reserved. WARRANTY Pelco will repair or replace, ...