REVISION A — 12/93

1

INSTALLATION MANUAL
BKMT10, BKMT10/230, AND BKMT10/24
BLOWER KITS

1.0 SCOPE

The information contained within this manual pertains
to the BKMT10, BKMT10/230, and BKMT10/24
blower kits.

Installation should be in accordance with all applicable
local and national electric codes, utilizing approved
materials only.

2.0 DESCRIPTION

The BKMT10, BKMT10/230, and BKMT10/24 are
continuous duty blower kits designed for use in either
the HT10V or MT10P liquid cooled enclosures.

2.1 MODELS

BKMT10

Blower kit, 6.7 watts @ 120 VAC,
60 Hz, 33 cfm

BKMT10/230

Blower kit, 8.9 watts @ 230 VAC,
50 Hz, 27 cfm

BKMT10/24

Blower kit, 1.92 watts @ 24 VDC
(AC rectified), 30 cfm

®

C468M

Figure 1. BKMT10 Series Blower Kit Installation

3.0 INSTALLATION

Install the blower kit in either the HT10V or MT10P
enclosure as outlined below.

1.

Remove the rear plate of the enclosure, and
then remove the camera sled.

2.

Assemble blower/blower bracket to sled as
shown in Figure 1, items 1–4.

3.

Install sled into enclosure.

4.

Wire blower to power source using butt
splices provided.

5.

Re-install rear plate of the enclosure.

Item

Description

Part Number

1

1/4-20 bolt

ZH1/420X.750SFS

2

Fan bracket

BK40004001COMP

3

Washer

ZH260X562X65C

4

Nut

ZH1/420NUTCHN

5

Fan Securement
Assembly

Screw

ZH4-40X.500SPP (Qty. 4)

Washer

ZH4LWSIS (Qty. 4)

Nut

ZH4-40NUTSH (Qty. 4)

6

Fans

24 VDC

EH4600105W3

120 VAC

EH4600115W3

230 VAC

EH4600123W3