Page 2 - CONTENTS; LIST OF ILLUSTRATIONS
2 C1517M-A (11/02) CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS .................................................................................................................................................................. 3 OVERVIEW ......................................................
Page 3 - IMPORTANT SAFEGUARDS AND WARNINGS; The product and/or manual may bear the following marks:; FOR QUALIFIED SERVICE PERSONNEL ONLY; Only use replacement parts recommended by Pelco.
C1517M-A (11/02) 3 IMPORTANT SAFEGUARDS AND WARNINGS 1. Read, keep, and follow these instructions. 2. Heed all warnings. 3. There are no user-serviceable parts inside this unit. Only authorized service personnel may open the unit. 4. Installation and servicing should only be done by qualified servic...
Page 4 - OVERVIEW; DESCRIPTION; Other features include the following:; FRONT VIEW
4 C1517M-A (11/02) OVERVIEW DESCRIPTION The ALM2064 Alarm Interface Unit provides alarm monitoring capability for up to 64 alarm inputs. Using Pelco’s proprietary M protocol,the alarm unit communicates with Pelco’s CM6800 matrix switcher via an RS-485 communication interface. The alarm unit can be l...
Page 5 - REAR VIEW; The rear of the alarm unit includes the following:
C1517M-A (11/02) 5 REAR VIEW The rear of the alarm unit includes the following: 1. Four groups of alarm inputs (labeled I, II, III, and IV) with removable mating plugs 2. One alarm output relay 3. One RS-485 output communication port (RJ-45 connector) 4. One RS-485 input communication port (RJ-45 co...
Page 6 - INSTALLATION; The following items are supplied:; MOUNTING; Rack-Mount Installation
6 C1517M-A (11/02) INSTALLATION The following items are supplied: • ALM2064 Alarm Interface Unit • Pelco screwdriver • 120 VAC power cord • 4 #10 screws with nylon washers • 220 VAC power cord • 10-foot (3 m) straight RJ-45 cable (8-conductor) MOUNTING Install the alarm unit in a 19-inch (48.26 cm) ...
Page 7 - WIRING ALARMS; DIP Switch Settings for Supervised/Unsupervised Modes
C1517M-A (11/02) 7 WIRING ALARMS All alarm wiring takes place using the four groups of connectors located on the rear of the alarm unit. The alarm unit has four groups ofinputs. Each group represents 16 alarm inputs: • Group I – 1-8, 9-16 • Group II – 17-24, 25-32 • Group III – 33-40, 41-48 • Group ...
Page 8 - Supervised Alarm Input Wiring
8 C1517M-A (11/02) SUPERVISED MODE Use this wiring mode if security is of utmost importance. Alarm inputs wired in supervised mode maximize the detection of tampering bydriving a constant current through a 10-kohm load. If a deviation in the steady current occurs, the alarm goes off. Please note tha...
Page 9 - Unsupervised Alarm Input Wiring
C1517M-A (11/02) 9 UNSUPERVISED MODE This wiring mode is easily defeated and should not be used in critical situations. For example, if you wire an alarm as unsupervised andnormally open, and a wire is cut, the alarm does not go off. If wiring for a normally open condition, unused inputs can be left...
Page 10 - MAKING THE ALARM CONNECTIONS; Alarm Input Connectors
10 C1517M-A (11/02) MAKING THE ALARM CONNECTIONS Each of the four groups contains two connectors with input mating plugs. The top of each mating plug has 16 screw terminals and thefront has 16 pins. The figure below indicates how the pins alternate between alarm inputs and their associated GND (grou...
Page 11 - WIRING EXTERNAL ALARM INPUTS USING ANALOG CIRCUITRY; TTL/CMOS External Alarm Wiring
C1517M-A (11/02) 11 WIRING EXTERNAL ALARM INPUTS USING ANALOG CIRCUITRY Figure 9 summarizes what is required in supervised and unsupervised modes to wire external alarm inputs using analog TTL/CMOS circuitry ratherthan alarms. ALARM ALARM ALARM ALARM ALARM ALARM 00714 Figure 9. TTL/CMOS External Ala...
Page 12 - RELAY OUTPUT WIRING; Relay Output Connector; SETTING THE DIP SWITCHES
12 C1517M-A (11/02) RELAY OUTPUT WIRING The alarm unit activates the relay when a valid alarm condition is sensed. To wire the relay output, you must do the following: 1. Remove the mating plug from the relay output connector. 2. Place the wires into the relay out wiring slots. 3. Tighten the screws...
Page 13 - Switch 2; Switch 1; DIP Switch
C1517M-A (11/02) 13 Figure 13. SW1 & SW2 Functions 1-32 33-64 Off Off Off Off Off On Off On On Off On Off On On On On Norm. Open (Unsupervised) Norm. Closed (Unsupervised) Supervised *Default to Norm. Open SERIAL PORT 1BAUD RATE1200: OFF, OFF, OFF2400: ON, OFF, OFF4800: OFF, ON , OFF9600: ON, ON...
Page 14 - OPERATION
14 C1517M-A (11/02) OPERATION The function of the alarm unit is to physically monitor all alarm inputs for a change of state. Green LEDs on the front and rear panels light when the power is turned on. The red alarm LED indicates whether the unit is offline or online. This light starts blinking in an...
Page 15 - TROUBLESHOOTING; PROBLEM; Why is the unit not operating as it should?
C1517M-A (11/02) 15 00699 TROUBLESHOOTING PROBLEM SOLUTION Why is the unit not operating as it should? Make sure the power cord is plugged in and the power switch is turned on. If the unitstill fails to operate, remove the front panel and press the reset button. Make sure theDIP switch settings are ...
Page 16 - APPENDIX A
16 C1517M-A (11/02) DIP Switch Address 1 2 3 4 5 6 7 8 1 0 0 0 0 0 0 0 0 2 1 0 0 0 0 0 0 0 3 0 1 0 0 0 0 0 0 4 1 1 0 0 0 0 0 0 5 0 0 1 0 0 0 0 0 6 1 0 1 0 0 0 0 0 7 0 1 1 0 0 0 0 0 8 1 1 1 0 0 0 0 0 9 0 0 0 1 0 0 0 0 10 1 0 0 1 0 0 0 0 11 0 1 0 1 0 0 0 0 12 1 1 0 1 0 0 0 0 13 0 0 1 1 0 0 0 0 14 1 0 ...
Page 18 - SPECIFICATIONS; ELECTRICAL; Data Ports; GENERAL; Operating Temperature:; MECHANICAL; Connectors
18 C1517M-A (11/02) SPECIFICATIONS ELECTRICAL Input Voltage: 100-240 VAC, 50/60 Hz, auto-ranging Power: 30 VA Data Ports Diagnostic: RS-232, DB9 connector Input: RS-485, RJ-45 connector Output: RS-485, RJ-45 connector Indicators: Two green power LEDsOne red alarm LED Fusing: 500 mA, 250V Relay Outpu...
Page 19 - REVISION HISTORY; REGULATORY NOTICES; Reorient or relocate the receiving antenna.; WARRANTY AND RETURN INFORMATION
C1517M-A (11/02) 19 REVISION HISTORY Manual # Date Comments C1517M 5/01 Original version. C1517M-A 11/02 Updated manual to new format. Revised Table A and updated Table B. ® Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco. © Copyright 2002, Pe...