Page 2 - NOTE: Packages received without an RMA number will not be accepted.; PUBLICATION NOTICE
3 0 4 0 / V 3 5 139001UA i I NSTALLATION A ND O PERATIONS M ANUAL P ATTON E LECTRONICS C O . COPYRIGHT NOTICE Copyright© 2000 Patton Electronics Co., All Rights Reserved. PROPRIETARY NOTICE The information contained herein is proprietary and confidential to Patton Electronics Co. Anyreproduction or ...
Page 3 - ii; EMISSION REQUIREMENTS; RADIO AND TV INTERFERENCE
3 0 4 0 / V 3 5 139001UA ii P ATTON E LECTRONICS C O . I NSTALLATION A ND O PERATIONS M ANUAL EMISSION REQUIREMENTS RADIO AND TV INTERFERENCE The Patton devices generate and use radio frequency energy, and if not installed and usedproperly—that is, in strict accordance with the manufacturer’s instru...
Page 4 - iii; Contents; CHAPTER 1 - OPERATION
3 0 4 0 / V 3 5 139001UA iii I NSTALLATION A ND O PERATIONS M ANUAL P ATTON E LECTRONICS C O . Contents CHAPTER 1 - OPERATION Channel Clocking ............................................................................................................................... 1-1Fallback Clocking ...........
Page 5 - Channel Clocking
3 0 4 0 / V 3 5 139001UA 1-1 I NSTALLATION A ND O PERATIONS M ANUAL O PERATION P ATTON E LECTRONICS C O . CHAPTER 1 - OPERATION The Patton 3040/V35 (CTS MD-V.35/TCB) is a network enhancement accessory intended forhigh speed synchronous or asynchronous V.35 modem, DSU/CSU, or port sharingapplications...
Page 6 - Channel Selection Modes
3 0 4 0 / V 3 5 139001UA 1-2 I NSTALLATION A ND O PERATIONS M ANUAL O PERATION P ATTON E LECTRONICS C O . Anti-streaming A typical problem often encountered is a “ STREAMING” remote terminal. The streaming problem can tie up an entire circuit until the offending device has recovered or is powereddow...
Page 7 - Channel Tail Circuits
3 0 4 0 / V 3 5 139001UA 1-3 I NSTALLATION A ND O PERATIONS M ANUAL O PERATION P ATTON E LECTRONICS C O . In the Scanning Mode the CTS 3040/V35 (CTS MD-V.35/TCB) scans each Sub-Channel, insequence, beginning with Sub-Channel 1. This rotational sequence is repeated continuallywith each attached Sub-C...
Page 8 - disable a Sub-Channel push the switch until it locks in the “; Power Supply
3 0 4 0 / V 3 5 139001UA 1-4 I NSTALLATION A ND O PERATIONS M ANUAL O PERATION P ATTON E LECTRONICS C O . Interface Connections All connections are made via industry standard CCITT V.35 (MR-34) female connectorslocated on the rear of the unit. The Following interface leads are implemented, Chassis (...
Page 9 - CHAPTER 2 - SETUP AND INSTALLATION; Power Connection
3 0 4 0 / V 3 5 139001UA 2-1 I NSTALLATION A ND O PERATIONS M ANUAL S ETUP & I NSTALLATION P ATTON E LECTRONICS C O . Caution, Disconnec t the POWER Be fore Removing The CoverVorsicht, Be for Deckung Abnehmen Mach Strom Zu. CHAPTER 2 - SETUP AND INSTALLATION Power Connection Before connecting th...
Page 10 - HS Option Not Enabled; JP1 Thru JP3 to; Factory Test Jumpers; Disassembly
3 0 4 0 / V 3 5 139001UA 2-2 I NSTALLATION A ND O PERATIONS M ANUAL S ETUP & I NSTALLATION P ATTON E LECTRONICS C O . Switch 18 - 1, 2, 3, 7 and 8 to OFF OFF OFF OFF OFF , 4, 5 and 6 to ON ON ON ON ON Anti-Stream timer = 2 M bitsAnti-Stream = DisabledBroadcast Data to Sub-ChannelsRX Clock Source...
Page 15 - DCE
3 0 4 0 / V 3 5 139001UA 2-7 I NSTALLATION A ND O PERATIONS M ANUAL S ETUP & I NSTALLATION P ATTON E LECTRONICS C O . Tail Circuit Buffers (SW16-4) The 3040/V35 (CTS MD-V.35/TCB) has a Tail Circuit Buffer that is automatically selectedwhen a Sub-Channel is set as a DTE. The buffer will provide c...
Page 17 - APPENDIX; Typical Tail Circuit Configuration
3 0 4 0 / V 3 5 139001UA A-1 A PPENDIX P ATTON E LECTRONICS C O . I NSTALLATION A ND O PERATIONS M ANUAL APPENDIX Typical Tail Circuit Configuration TT-Y,AA RT-V,X ETT-U,V RT-V,X RT-V,X TT-Y,AA RT-V,X TT-Y,AA Terminal Buffer Slave TX Clocking ETT-U,W Slave TX Clocking ETT-U,W Data Internal TX Clocki...
Page 18 - M-34 Interface Pins Supported; DB-25 Interface Pins Supported
3 0 4 0 / V 3 5 139001UA A-2 A PPENDIX P ATTON E LECTRONICS C O . I NSTALLATION A ND O PERATIONS M ANUAL M-34 Interface Pins Supported Z D D J J B B F F L L C C H H M M E E K K M K B S G F C D L R R D ( A ) V R T ( A ) D C T S J N T R D ( B ) A F G E D S R P T D ( A ) C R T S H D T R S T D ( B ) W E...
Page 19 - Master Port is a DTE
3 0 4 0 / V 3 5 139001UA A-3 A PPENDIX P ATTON E LECTRONICS C O . I NSTALLATION A ND O PERATIONS M ANUAL Master DTE / Sub-Channel DCE Interface Flow Diagram Master DTE / Sub-Channel DTE Interface Flow Diagram Pins P,S TD Pins R,T RD Pin C RTSPin D CTSPin E DSRPin F DCDPin H DTR Pins Y,AA TT Pins V,X...
Page 20 - Master Port is a DCE
3 0 4 0 / V 3 5 139001UA A-4 A PPENDIX P ATTON E LECTRONICS C O . I NSTALLATION A ND O PERATIONS M ANUAL Master DCE / Sub-Channel DCE Interface Flow Diagram Master DCE / Sub-Channel DTE Interface Flow Diagram Master RX Clock Selection Logic Master TX Clock Selection Logic Master Port is a DCE Switch...
Page 21 - TECHNICAL SPECIFICATIONS
3 0 4 0 / V 3 5 139001UA A-5 A PPENDIX P ATTON E LECTRONICS C O . I NSTALLATION A ND O PERATIONS M ANUAL TECHNICAL SPECIFICATIONS Applications Multiple V.35 Sync or Async DCE or DTE devicessharing one V.35 DCE or DTE link Capacity One to Four V.35 Sync or Async DTE or DCEdevices One V.35 DCE or DTE ...